Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ supplier

Large Image :  Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLP60EQ / 1606XLP60EQ

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $114.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLP60EQ

This page documents the 1606-XLP60EQ, a member of the Bulletin 1606 switched-mode power supply range (1606-XLP Compact Power Supply): 24 V output at 2.5 A, 60 W, with AC 100...240 V input. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLP60EQ
Product family1606-XLP Compact Power Supply
Output voltage, nominal24 V
Output current, nominal2.5 A
Output power60 W
Input, ACAC 100...240 V
Input, DCDC 110...300 V
Feature or limitation flagnone printed

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLP1606-XLP Compact Power Supply
Digits60rated output power in watts
Voltage letterE24...28 V
Trailing suffixQNEC Class 2 limited-power output

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XLP line

Series attributePublished value
Series1606-XLP Compact Power Supply
Power range15...100 W
Overload / boostnone - the compact line runs without a power boost stage
Reserve currentno published reserve current
Efficiency, typical77.2...91.0 % typical depending on model
Operating temperature-10...+70 degC, with -40 degC starting variants
Terminalsscrew and spring terminals, plug connectors on the -XLP50EZ
Mains versionssingle-phase 100...240 V AC and two-phase 380...480 V AC versions

The line exists for the reason printed against it: the narrow 22.5...73 mm housings for shallow enclosures and small loads. Against this string that means the 2.5 A output is one point inside a 15...100 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

Three calculations follow from the row above. The output load is the sum of everything on the rail against 2.5 A, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the AC 100...240 V window, not at nominal mains, because that is where the current is highest.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLP60EQ, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers in the XLP series are 1606-XLP100E,1606-XLP100E-2, 1606-XLP100F, 1606-XLP15A. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Redundancy modules are a separate product, not a feature. Decoupling diodes and MOSFET redundancy modules sit beside the supply, not inside it: two supplies in parallel without a module share current badly and fail as one. The module is selected by the load current and by whether the two feeds come from the same or from different sources, which is why the module string carries its own current rating. This page documents 1606-XLP60EQ.

Terminals decide the wiring time more than the rating does. Spring terminals, screw terminals, push-in terminals and plug connectors all appear on this bulletin at the same power class. The terminal style is chosen by how the panel is wired and by whether the unit is expected to be swapped on site, and it is part of the catalog string rather than a build option added later. This page documents 1606-XLP60EQ.

Lifecycle status changes the spare, not the specification. A discontinued string keeps its published electrical figures; what changes is the path Rockwell prints for it: direct replacement, engineering replacement with different mounting or wiring, or no planned replacement. The replacement category is the amount of re-validation work a panel inherits, and it is the reason a bill of materials is read with the lifecycle column next to the rating. This page documents 1606-XLP60EQ.

This string publishes a DC input window as well as an AC one. DC 110...300 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.

The Class 2 marking is a wiring permission, not a rating. A Class 2 limited-power output may be wired with the smaller cable classes and without the same separation rules as a general-purpose circuit, which is why a compact supply carries the marking for sensor and low-power circuits. The limit is an output limit rather than a supply limit, so a Class 2 string does not become a general-purpose supply by loading it harder.

Checks before substituting another 1606 number

Four checks decide whether a different string can replace this one in an existing panel. Output voltage and rated current have to match the load, not merely exceed it, because a supply oversized on current derates differently at high ambient. The input window has to include the actual mains at the site, including the three-phase and regional builds that share an output with a single-phase frame. The terminal style has to fit the existing wiring, since screw, spring, push-in and plug connectors are not interchangeable in a cabinet that is already wired. And the lifecycle category has to be read before the part is ordered, because a direct replacement keeps the footprint while an engineering replacement moves it.

What this string fixes is narrower than it looks: the power stage, the output voltage and the input window. What the trailing characters add is mechanical and environmental, and what the lifecycle row adds is how much of the panel survives a replacement. Keeping those three groups apart is how a bill of materials stays readable after the first revision. This page documents 1606-XLP60EQ.

Questions this catalog number answers

What is 1606-XLP60EQ? 1606-XLP60EQ is a 1606-XLP Compact Power Supply in the Bulletin 1606 range: 24 V output at 2.5 A, 60 W, with AC 100...240 V input.

Is 1606-XLP60EQ current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLP60EQ? The input current at the lowest voltage of the AC 100...240 V window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XLP60EQ the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Twelve of the 129 1606 records carried on this site, ordered by how close their codes sit to this one. This page is 1606-XLP60EQ.

This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 1606-XLP60EQ page is one entry in it. Sibling codes of the same group are one click away from that page.

Contact Details