Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE supplier

Large Image :  Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLX240EE / 1606XLX240EE

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $88.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLX240EE

This page documents the 1606-XLX240EE, a member of the Bulletin 1606 switched-mode power supply range: no output voltage printed for this string output at no output current printed, no output power printed, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLX240EE
Product familyBulletin 1606 switched-mode power supply
Output voltage, nominalno output voltage printed for this string
Output current, nominalno output current printed
Output powerno output power printed
Input, ACnot printed for this string
Input, DCnot printed for this string
Feature or limitation flaglegacy 1606-XL unit

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLXthe original XL line
Digits240rated output power in watts
Voltage letterE24...28 V
Trailing suffixEregional unit for Europe

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XL line

Series attributePublished value
Series1606-XL Power Supply (legacy line)
Power range60...960 W
Overload / boostnot published for this line in the current technical data
Reserve currentnot published for this line in the current technical data
Efficiency, typicalnot published for this line in the current technical data
Operating temperaturenot published for this line in the current technical data
Terminalsscrew terminals
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the no output current printed output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates. This page documents 1606-XLX240EE.

Load, heat and input protection

Sizing from this row means three numbers that are rarely written down together: the continuous rail load against no output current printed, the inrush allowance taken from the published reserve of the line, and the heat the unit leaves in the enclosure. The third one is the one that decides whether the cabinet needs a fan, and it follows from the efficiency band for this frame rather than from the watts figure alone. The input current at the lowest point of the published window is the fourth, and it is the one the branch device is sized against.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLX240EE, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Efficiency is a thermal number before it is an energy number. A 90 to 95 percent efficiency figure on a 480 W supply leaves 25 to 48 W of heat inside the enclosure, which is the difference between a sealed cabinet that holds temperature and one that needs forced ventilation. The efficiency band is published per series rather than per model, so the number to check is the one for the frame size that was ordered. This page documents 1606-XLX240EE.

Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current. This page documents 1606-XLX240EE.

A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line. This page documents 1606-XLX240EE.

The feature flag on this row reads: legacy 1606-XL unit. That flag is the field that separates 1606-XLX240EE from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

Checks before substituting another 1606 number

The comparison that matters before a substitute is ordered is not the watts figure. It is whether the output matches the rail, whether the continuous current covers the load schedule with the published reserve left as inrush, whether the input frame matches the mains at the site, whether the terminals fit the existing wiring, and what the lifecycle category says about re-validating the panel. Two strings that agree on watts can disagree on all five. This page documents 1606-XLX240EE.

What this string fixes is narrower than it looks: the power stage, the output voltage and the input window. What the trailing characters add is mechanical and environmental, and what the lifecycle row adds is how much of the panel survives a replacement. Keeping those three groups apart is how a bill of materials stays readable after the first revision. This page documents 1606-XLX240EE.

Questions this catalog number answers

What is 1606-XLX240EE? 1606-XLX240EE is a switched-mode power supply in the Bulletin 1606 range: no output voltage printed for this string output at no output current printed, no output power printed, with an input window printed in the selection table.

Is 1606-XLX240EE current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLX240EE? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XLX240EE the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

This page links twelve of the 129 1606 records on this site; the closest rating codes come first. This page is 1606-XLX240EE.

For the surrounding range, open the Allen Bradley Other PLC catalogue index — 1606-XLX240EE is listed there beside the rest of the other-PLC group. It is the entry point used when a project list is assembled group by group.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)