logo
Home ProductsAllen Bradley Other PLC

Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2

China Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier
Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2 supplier

Large Image :  Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLSBATASSY2 / 1606XLSBATASSY2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $69.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLSBATASSY2

This page documents the 1606-XLSBATASSY2, a member of the Bulletin 1606 switched-mode power supply range: 12 V battery module output at 26 Ah, no output power printed, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLSBATASSY2
Product familyBulletin 1606 switched-mode power supply
Output voltage, nominal12 V battery module
Output current, nominal26 Ah
Output powerno output power printed
Input, ACnot printed for this string
Input, DCnot printed for this string
Feature or limitation flagbattery module for 1606-XLS240-UPS, 214 x 179 x 158 mm

Where this model sits in the XL line

Series attributePublished value
Series1606-XL Power Supply (legacy line)
Power range60...960 W
Overload / boostnot published for this line in the current technical data
Reserve currentnot published for this line in the current technical data
Efficiency, typicalnot published for this line in the current technical data
Operating temperaturenot published for this line in the current technical data
Terminalsscrew terminals
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the 26 Ah output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

Three calculations follow from the row above. The output load is the sum of everything on the rail against 26 Ah, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the published window, not at nominal mains, because that is where the current is highest.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLSBATASSY2, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers to 1606-XLSBATASSY2 in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve.

The -3 and regional suffixes are input variants. A trailing numeric suffix on this bulletin marks an input or regional variant rather than a different output: 380...480 V AC three-phase builds and regional mains builds read the same output current from a different input window. Substituting one for the other across a project is an input-side change, and the output side of the panel does not have to be re-validated.

Dc input is a separate application, not an ac fallback. The DC-input members of this bulletin take 110...300 V DC or a battery-range window, and they exist for rail, vehicle and battery-backed panels. A DC input is not an AC supply with a rectifier bolted on the front: the input window, the inrush and the branch protection all change, and the string carries the DC figure explicitly.

The feature flag on this row reads: battery module for 1606-XLS240-UPS, 214 x 179 x 158 mm. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

This string belongs to the battery-backed group. Battery modules, buffer modules and UPS units are rated in ampere-hours or in holdup time rather than in continuous watts, and they are selected from the load and from the ride-through the process needs. The charging circuit is part of the unit, so the battery string and the supply are matched as a pair rather than sized independently.

Checks before substituting another 1606 number

Four checks decide whether a different string can replace this one in an existing panel. Output voltage and rated current have to match the load, not merely exceed it, because a supply oversized on current derates differently at high ambient. The input window has to include the actual mains at the site, including the three-phase and regional builds that share an output with a single-phase frame. The terminal style has to fit the existing wiring, since screw, spring, push-in and plug connectors are not interchangeable in a cabinet that is already wired. And the lifecycle category has to be read before the part is ordered, because a direct replacement keeps the footprint while an engineering replacement moves it.

The published figures on this row are the ones a panel builder can be held to. They are also the ones that change when the string changes by a suffix, so a substitution made on the watts figure alone can move the terminals, the coating or the input frame without anyone noticing until the unit is on the bench.

Questions this catalog number answers

What is 1606-XLSBATASSY2? 1606-XLSBATASSY2 is a switched-mode power supply in the Bulletin 1606 range: 12 V battery module output at 26 Ah, no output power printed, with an input window printed in the selection table.

Is 1606-XLSBATASSY2 current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLSBATASSY2? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

Role of this string in the range

This number is an accessory or a legacy-line member rather than a stand-alone supply row: battery module for 1606-XLS240-UPS, 214 x 179 x 158 mm. Its own catalog string therefore carries the family and the function rather than an output rating, and it is selected by the supply it is paired with - the current rating of that supply, the rail it serves and the mounting it needs - instead of by a watts figure. That is why the selection row above marks the electrical fields the publication does not print for this catalog number.

No price and no lead time is implied on this page. For 1606-XLSBATASSY2 the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Of the 129 1606 records carried here, these twelve stand closest to this catalog number. This page is 1606-XLSBATASSY2.

Site tree: the Allen Bradley Other PLC index carries 1606-XLSBATASSY2 together with the other entries of the other-PLC group, which is where a catalogue walk usually starts. It is the entry point used when a project list is assembled group by group.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)