logo
Home ProductsAllen Bradley Other PLC

Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F

China Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier
Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F supplier

Large Image :  Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLS480F / 1606XLS480F

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $388.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLS480F

This page documents the 1606-XLS480F, a member of the Bulletin 1606 switched-mode power supply range (1606-XLS Performance Power Supply): 48 V output at 10 A, 480 W, with AC 100...240 V input. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLS480F
Product family1606-XLS Performance Power Supply
Output voltage, nominal48 V
Output current, nominal10 A
Output power480 W
Input, ACAC 100...240 V
Input, DCDC 110...150 V
Feature or limitation flagnone printed

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLS1606-XLS Performance Power Supply
Digits480rated output power in watts
Voltage letterF48...56 V

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XLS line

Series attributePublished value
Series1606-XLS Performance Power Supply
Power range80...960 W
Overload / boost150 % for 5 s
Reserve current50 % additional current
Efficiency, typical90.0...95.3 % typical depending on model
Operating temperature-25...+70 degC, derating above 60 degC
Terminalsspring terminals, screw terminals on the 960 W frame sizes
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the line that carries power factor correction, DC OK relay contacts and the highest efficiency in the bulletin. Against this string that means the 10 A output is one point inside a 80...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

The rail load is the first number and it is 10 A; the second is the inrush the loads draw at switch-on, which the published reserve covers only for the time the line states; the third is the input current at the lowest point of the AC 100...240 V window, which is what the branch device has to carry without tripping on a cold start. A supply sized on nominal mains current alone fails the third check in winter.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLS480F, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers in the XLS series are 1606-XLS120E,1606-XLS120EA, 1606-XLS180B, 1606-XLS240-UPS. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Redundancy modules are a separate product, not a feature. Decoupling diodes and MOSFET redundancy modules sit beside the supply, not inside it: two supplies in parallel without a module share current badly and fail as one. The module is selected by the load current and by whether the two feeds come from the same or from different sources, which is why the module string carries its own current rating. This page covers 1606-XLS480F and its ordering options.

Terminals decide the wiring time more than the rating does. Spring terminals, screw terminals, push-in terminals and plug connectors all appear on this bulletin at the same power class. The terminal style is chosen by how the panel is wired and by whether the unit is expected to be swapped on site, and it is part of the catalog string rather than a build option added later. This page covers 1606-XLS480F and its ordering options.

Lifecycle status changes the spare, not the specification. A discontinued string keeps its published electrical figures; what changes is the path Rockwell prints for it: direct replacement, engineering replacement with different mounting or wiring, or no planned replacement. The replacement category is the amount of re-validation work a panel inherits, and it is the reason a bill of materials is read with the lifecycle column next to the rating. This page covers 1606-XLS480F and its ordering options.

This string publishes a DC input window as well as an AC one. DC 110...150 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.

At 480 W this row sits in the high-power frames. Above roughly 480 W the terminals change to the larger screw or push-in sets and the unit needs the clearance a full-depth cabinet gives it, which is the mechanical difference a drawing has to show. A supply of this size also turns the enclosure thermal calculation into the deciding one, because the loss inside the cabinet is now tens of watts.

Checks before substituting another 1606 number

Four checks decide whether a different string can replace this one in an existing panel. Output voltage and rated current have to match the load, not merely exceed it, because a supply oversized on current derates differently at high ambient. The input window has to include the actual mains at the site, including the three-phase and regional builds that share an output with a single-phase frame. The terminal style has to fit the existing wiring, since screw, spring, push-in and plug connectors are not interchangeable in a cabinet that is already wired. And the lifecycle category has to be read before the part is ordered, because a direct replacement keeps the footprint while an engineering replacement moves it.

The published figures on this row are the ones a panel builder can be held to. They are also the ones that change when the string changes by a suffix, so a substitution made on the watts figure alone can move the terminals, the coating or the input frame without anyone noticing until the unit is on the bench. This page covers 1606-XLS480F and its ordering options.

Questions this catalog number answers

What is 1606-XLS480F? 1606-XLS480F is a 1606-XLS Performance Power Supply in the Bulletin 1606 range: 48 V output at 10 A, 480 W, with AC 100...240 V input.

Is 1606-XLS480F current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLS480F? The input current at the lowest voltage of the AC 100...240 V window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XLS480F the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Of the 129 1606 records carried here, these twelve stand closest to this catalog number. This page is 1606-XLS480F.

Site tree: the Allen Bradley Other PLC index carries 1606-XLS480F together with the other entries of the other-PLC group, which is where a catalogue walk usually starts. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)