This page documents the 1606-XLS480E-D, a member of the Bulletin 1606 switched-mode power supply range (1606-XLS Performance Power Supply): 24 V output at 20 A, 480 W, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.
| Attribute | Published value |
| Catalog number | 1606-XLS480E-D |
| Product family | 1606-XLS Performance Power Supply |
| Output voltage, nominal | 24 V |
| Output current, nominal | 20 A |
| Output power | 480 W |
| Input, AC | not printed for this string |
| Input, DC | DC 600 V |
| Feature or limitation flag | DC-bus converter for intermediate DC bus |
| Position | Value | Meaning |
| Prefix | 1606 | Bulletin number for switched-mode power supplies |
| Series letters | XLS | 1606-XLS Performance Power Supply |
| Digits | 480 | rated output power in watts |
| Voltage letter | E | 24...28 V |
| Trailing suffix | -D | extended DC input range |
The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.
| Series attribute | Published value |
| Series | 1606-XLS Performance Power Supply |
| Power range | 80...960 W |
| Overload / boost | 150 % for 5 s |
| Reserve current | 50 % additional current |
| Efficiency, typical | 90.0...95.3 % typical depending on model |
| Operating temperature | -25...+70 degC, derating above 60 degC |
| Terminals | spring terminals, screw terminals on the 960 W frame sizes |
| Mains versions | single-phase 100...240 V AC and three-phase 380...480 V AC versions |
The line exists for the reason printed against it: the line that carries power factor correction, DC OK relay contacts and the highest efficiency in the bulletin. Against this string that means the 20 A output is one point inside a 80...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.
Three calculations follow from the row above. The output load is the sum of everything on the rail against 20 A, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the published window, not at nominal mains, because that is where the current is highest.
A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLS480E-D, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.
Neighbouring numbers in the XLS series are 1606-XLS120E,1606-XLS120EA, 1606-XLS180B, 1606-XLS240-UPS. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.
Terminals decide the wiring time more than the rating does. Spring terminals, screw terminals, push-in terminals and plug connectors all appear on this bulletin at the same power class. The terminal style is chosen by how the panel is wired and by whether the unit is expected to be swapped on site, and it is part of the catalog string rather than a build option added later. This page documents 1606-XLS480E-D.
Lifecycle status changes the spare, not the specification. A discontinued string keeps its published electrical figures; what changes is the path Rockwell prints for it: direct replacement, engineering replacement with different mounting or wiring, or no planned replacement. The replacement category is the amount of re-validation work a panel inherits, and it is the reason a bill of materials is read with the lifecycle column next to the rating. This page documents 1606-XLS480E-D.
Efficiency is a thermal number before it is an energy number. A 90 to 95 percent efficiency figure on a 480 W supply leaves 25 to 48 W of heat inside the enclosure, which is the difference between a sealed cabinet that holds temperature and one that needs forced ventilation. The efficiency band is published per series rather than per model, so the number to check is the one for the frame size that was ordered. This page documents 1606-XLS480E-D.
This string publishes a DC input window as well as an AC one. DC 600 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.
The feature flag on this row reads: DC-bus converter for intermediate DC bus. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.
At 480 W this row sits in the high-power frames. Above roughly 480 W the terminals change to the larger screw or push-in sets and the unit needs the clearance a full-depth cabinet gives it, which is the mechanical difference a drawing has to show. A supply of this size also turns the enclosure thermal calculation into the deciding one, because the loss inside the cabinet is now tens of watts.
A substitution audit for 1606-XLS480E-D runs in a fixed order: output voltage, then continuous current against the load schedule, then the input frame actually present at the site, then the terminal style, and last the lifecycle category. Any one of the five can invalidate a part that looks correct in a catalogue row, and the cheapest place to catch it is the bill of materials rather than the parts counter during a shutdown.
The published figures on this row are the ones a panel builder can be held to. They are also the ones that change when the string changes by a suffix, so a substitution made on the watts figure alone can move the terminals, the coating or the input frame without anyone noticing until the unit is on the bench. This page documents 1606-XLS480E-D.
What is 1606-XLS480E-D? 1606-XLS480E-D is a 1606-XLS Performance Power Supply in the Bulletin 1606 range: 24 V output at 20 A, 480 W, with an input window printed in the selection table.
Is 1606-XLS480E-D current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.
What decides the input protection for 1606-XLS480E-D? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.
No price and no lead time is implied on this page. For 1606-XLS480E-D the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.