This page documents the 1606-XLS240K, a member of the Bulletin 1606 switched-mode power supply range (1606-XLS Performance Power Supply): 28 V output at 8.6 A, 240 W, with AC 100...240 V input. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.
| Attribute | Published value |
| Catalog number | 1606-XLS240K |
| Product family | 1606-XLS Performance Power Supply |
| Output voltage, nominal | 28 V |
| Output current, nominal | 8.6 A |
| Output power | 240 W |
| Input, AC | AC 100...240 V |
| Input, DC | DC 110...150 V |
| Feature or limitation flag | 28...32 V adjustable output |
| Position | Value | Meaning |
| Prefix | 1606 | Bulletin number for switched-mode power supplies |
| Series letters | XLS | 1606-XLS Performance Power Supply |
| Digits | 240 | rated output power in watts |
| Voltage letter | K | not in the published voltage table |
The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.
| Series attribute | Published value |
| Series | 1606-XLS Performance Power Supply |
| Power range | 80...960 W |
| Overload / boost | 150 % for 5 s |
| Reserve current | 50 % additional current |
| Efficiency, typical | 90.0...95.3 % typical depending on model |
| Operating temperature | -25...+70 degC, derating above 60 degC |
| Terminals | spring terminals, screw terminals on the 960 W frame sizes |
| Mains versions | single-phase 100...240 V AC and three-phase 380...480 V AC versions |
The line exists for the reason printed against it: the line that carries power factor correction, DC OK relay contacts and the highest efficiency in the bulletin. Against this string that means the 8.6 A output is one point inside a 80...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.
Sizing from this row means three numbers that are rarely written down together: the continuous rail load against 8.6 A, the inrush allowance taken from the published reserve of the line, and the heat the unit leaves in the enclosure. The third one is the one that decides whether the cabinet needs a fan, and it follows from the efficiency band for this frame rather than from the watts figure alone. The input current at the lowest point of the AC 100...240 V window is the fourth, and it is the one the branch device is sized against.
A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLS240K, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.
Neighbouring numbers in the XLS series are 1606-XLS120E,1606-XLS120EA, 1606-XLS180B, 1606-XLS240-UPS. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.
Redundancy modules are a separate product, not a feature. Decoupling diodes and MOSFET redundancy modules sit beside the supply, not inside it: two supplies in parallel without a module share current badly and fail as one. The module is selected by the load current and by whether the two feeds come from the same or from different sources, which is why the module string carries its own current rating. The catalog number covered on this page is 1606-XLS240K.
Terminals decide the wiring time more than the rating does. Spring terminals, screw terminals, push-in terminals and plug connectors all appear on this bulletin at the same power class. The terminal style is chosen by how the panel is wired and by whether the unit is expected to be swapped on site, and it is part of the catalog string rather than a build option added later. The catalog number covered on this page is 1606-XLS240K.
Lifecycle status changes the spare, not the specification. A discontinued string keeps its published electrical figures; what changes is the path Rockwell prints for it: direct replacement, engineering replacement with different mounting or wiring, or no planned replacement. The replacement category is the amount of re-validation work a panel inherits, and it is the reason a bill of materials is read with the lifecycle column next to the rating. The catalog number covered on this page is 1606-XLS240K.
This string publishes a DC input window as well as an AC one. DC 110...150 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.
The feature flag on this row reads: 28...32 V adjustable output. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.
A substitution audit for 1606-XLS240K runs in a fixed order: output voltage, then continuous current against the load schedule, then the input frame actually present at the site, then the terminal style, and last the lifecycle category. Any one of the five can invalidate a part that looks correct in a catalogue row, and the cheapest place to catch it is the bill of materials rather than the parts counter during a shutdown.
What this string fixes is narrower than it looks: the power stage, the output voltage and the input window. What the trailing characters add is mechanical and environmental, and what the lifecycle row adds is how much of the panel survives a replacement. Keeping those three groups apart is how a bill of materials stays readable after the first revision. The catalog number covered on this page is 1606-XLS240K.
What is 1606-XLS240K? 1606-XLS240K is a 1606-XLS Performance Power Supply in the Bulletin 1606 range: 28 V output at 8.6 A, 240 W, with AC 100...240 V input.
Is 1606-XLS240K current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.
What decides the input protection for 1606-XLS240K? The input current at the lowest voltage of the AC 100...240 V window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.
No price and no lead time is implied on this page. For 1606-XLS240K the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.
This page links twelve of the 129 1606 records on this site; the closest rating codes come first. This page is 1606-XLS240K.
For the surrounding range, open the Allen Bradley Other PLC catalogue index — 1606-XLS240K is listed there beside the rest of the other-PLC group. The index sits one level above this page in the site tree.