Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier Allen Bradley Power Supply 1606-XLERED / 1606XLERED supplier

Large Image :  Allen Bradley Power Supply 1606-XLERED / 1606XLERED

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLERED / 1606XLERED

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $148.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLERED

This page documents the 1606-XLERED, a member of the Bulletin 1606 switched-mode power supply range: DC 24...48 V output at 2x 10 A / 20 A, no output power printed, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLERED
Product familyBulletin 1606 switched-mode power supply
Output voltage, nominalDC 24...48 V
Output current, nominal2x 10 A / 20 A
Output powerno output power printed
Input, ACnot printed for this string
Input, DCDC 18...60 V
Feature or limitation flagdual-input diode redundancy module

Where this model sits in the XL line

Series attributePublished value
Series1606-XL Power Supply (legacy line)
Power range60...960 W
Overload / boostnot published for this line in the current technical data
Reserve currentnot published for this line in the current technical data
Efficiency, typicalnot published for this line in the current technical data
Operating temperaturenot published for this line in the current technical data
Terminalsscrew terminals
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the 2x 10 A / 20 A output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

Three calculations follow from the row above. The output load is the sum of everything on the rail against 2x 10 A / 20 A, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the published window, not at nominal mains, because that is where the current is highest.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLERED, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers to 1606-XLERED in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current.

A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line.

Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve.

This string publishes a DC input window as well as an AC one. DC 18...60 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.

The feature flag on this row reads: dual-input diode redundancy module. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

This string belongs to the redundancy group. Its job is to decouple two feeds so that one supply failing does not drag the other down, and it is rated in load current rather than in output watts. The group is selected by the load and by whether the two feeds share a source, and the module is always a separate enclosure beside the supplies rather than a stage inside one.

Checks before substituting another 1606 number

The comparison that matters before a substitute is ordered is not the watts figure. It is whether the output matches the rail, whether the continuous current covers the load schedule with the published reserve left as inrush, whether the input frame matches the mains at the site, whether the terminals fit the existing wiring, and what the lifecycle category says about re-validating the panel. Two strings that agree on watts can disagree on all five.

The published figures on this row are the ones a panel builder can be held to. They are also the ones that change when the string changes by a suffix, so a substitution made on the watts figure alone can move the terminals, the coating or the input frame without anyone noticing until the unit is on the bench.

Questions this catalog number answers

What is 1606-XLERED? 1606-XLERED is a switched-mode power supply in the Bulletin 1606 range: DC 24...48 V output at 2x 10 A / 20 A, no output power printed, with an input window printed in the selection table.

Is 1606-XLERED current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLERED? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

Role of this string in the range

This number is an accessory or a legacy-line member rather than a stand-alone supply row: dual-input diode redundancy module. Its own catalog string therefore carries the family and the function rather than an output rating, and it is selected by the supply it is paired with - the current rating of that supply, the rail it serves and the mounting it needs - instead of by a watts figure. That is why the selection row above marks the electrical fields the publication does not print for this catalog number.

No price and no lead time is implied on this page. For 1606-XLERED the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Twelve of the 129 1606 records carried on this site, ordered by how close their codes sit to this one. This page is 1606-XLERED.

This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 1606-XLERED page is one entry in it. Sibling codes of the same group are one click away from that page.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)