logo
Home ProductsAllen Bradley Other PLC

Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2

China Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier
Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2 supplier

Large Image :  Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLE96B-2 / 1606XLE96B2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $86.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLE96B-2

This page documents the 1606-XLE96B-2, a member of the Bulletin 1606 switched-mode power supply range (1606-XLE Essential Power Supply): 12 V output at 8 A, 96 W, with 2 AC 380...480 V input. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLE96B-2
Product family1606-XLE Essential Power Supply
Output voltage, nominal12 V
Output current, nominal8 A
Output power96 W
Input, AC2 AC 380...480 V
Input, DCnot printed for this string
Feature or limitation flagtwo-phase input

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLE1606-XLE Essential Power Supply
Digits96rated output power in watts
Voltage letterB12 V
Trailing suffix-2two-phase input

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XLE line

Series attributePublished value
Series1606-XLE Essential Power Supply
Power range80...960 W
Overload / boost120 % power reserve
Reserve current20 % additional current
Efficiency, typical85.4...96.3 % typical depending on model
Operating temperature-25...+70 degC on most models, 0...+70 degC on the regional 240 W units
Terminalsscrew terminals as standard, spring and push-in variants in the same power class
Mains versionssingle-phase 100...240 V AC, two-phase and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the cost-optimised line for panel builders who need a defined reserve without the XLS feature set. Against this string that means the 8 A output is one point inside a 80...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

Three calculations follow from the row above. The output load is the sum of everything on the rail against 8 A, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the 2 AC 380...480 V window, not at nominal mains, because that is where the current is highest.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLE96B-2, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers in the XLE series are 1606-XLE120B, 1606-XLE120E,1606-XLE120EC,1606-XLE120EL,1606-XLE120EH,1606-XLE120ED, 1606-XLE120E-2. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Lifecycle status changes the spare, not the specification. A discontinued string keeps its published electrical figures; what changes is the path Rockwell prints for it: direct replacement, engineering replacement with different mounting or wiring, or no planned replacement. The replacement category is the amount of re-validation work a panel inherits, and it is the reason a bill of materials is read with the lifecycle column next to the rating. The catalog number covered on this page is 1606-XLE96B-2.

Efficiency is a thermal number before it is an energy number. A 90 to 95 percent efficiency figure on a 480 W supply leaves 25 to 48 W of heat inside the enclosure, which is the difference between a sealed cabinet that holds temperature and one that needs forced ventilation. The efficiency band is published per series rather than per model, so the number to check is the one for the frame size that was ordered. The catalog number covered on this page is 1606-XLE96B-2.

Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current. The catalog number covered on this page is 1606-XLE96B-2.

This string is a three-phase build. The 380...480 V AC frame exists where the load is too large for a single-phase branch, and the input terminals, the inrush and the branch protection are three-phase ones. A panel that carries this unit cannot be fed from a single-phase drop even though the output voltage is the same as a single-phase model of the same wattage.

The feature flag on this row reads: two-phase input. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

Checks before substituting another 1606 number

A substitution audit for 1606-XLE96B-2 runs in a fixed order: output voltage, then continuous current against the load schedule, then the input frame actually present at the site, then the terminal style, and last the lifecycle category. Any one of the five can invalidate a part that looks correct in a catalogue row, and the cheapest place to catch it is the bill of materials rather than the parts counter during a shutdown.

Read this row against the panel it will feed rather than against the catalogue page: the output is what the rail needs, the reserve is what the inrush may borrow, the efficiency is what the cabinet must dissipate, and the input window is what the site must supply. A number that satisfies the first three and fails the fourth is a unit that is correct on paper and unusable on a low-line branch. The catalog number covered on this page is 1606-XLE96B-2.

Questions this catalog number answers

What is 1606-XLE96B-2? 1606-XLE96B-2 is a 1606-XLE Essential Power Supply in the Bulletin 1606 range: 12 V output at 8 A, 96 W, with 2 AC 380...480 V input.

Is 1606-XLE96B-2 current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLE96B-2? The input current at the lowest voltage of the 2 AC 380...480 V window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XLE96B-2 the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Twelve of the 129 1606 records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 1606-XLE96B-2.

Group index: Allen Bradley Other PLC. 1606-XLE96B-2 is filed under that heading in the site's own product tree. Reach it directly if the suffix on this record still needs confirming against a sibling.