Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E supplier

Large Image :  Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XLE80E / 1606XLE80E

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $348.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XLE80E

This page documents the 1606-XLE80E, a member of the Bulletin 1606 switched-mode power supply range (1606-XLE Essential Power Supply): 24 V output at 3.3 A, 80 W, with AC 100...240 V input. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XLE80E
Product family1606-XLE Essential Power Supply
Output voltage, nominal24 V
Output current, nominal3.3 A
Output power80 W
Input, ACAC 100...240 V
Input, DCDC 110...300 V
Feature or limitation flagremote shutdown input

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLE1606-XLE Essential Power Supply
Digits80rated output power in watts
Voltage letterE24...28 V

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XLE line

Series attributePublished value
Series1606-XLE Essential Power Supply
Power range80...960 W
Overload / boost120 % power reserve
Reserve current20 % additional current
Efficiency, typical85.4...96.3 % typical depending on model
Operating temperature-25...+70 degC on most models, 0...+70 degC on the regional 240 W units
Terminalsscrew terminals as standard, spring and push-in variants in the same power class
Mains versionssingle-phase 100...240 V AC, two-phase and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the cost-optimised line for panel builders who need a defined reserve without the XLS feature set. Against this string that means the 3.3 A output is one point inside a 80...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Load, heat and input protection

Three calculations follow from the row above. The output load is the sum of everything on the rail against 3.3 A, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the AC 100...240 V window, not at nominal mains, because that is where the current is highest.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLE80E, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers in the XLE series are 1606-XLE120B, 1606-XLE120E,1606-XLE120EC,1606-XLE120EL,1606-XLE120EH,1606-XLE120ED, 1606-XLE120E-2. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current. The catalog number covered on this page is 1606-XLE80E.

A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line. The catalog number covered on this page is 1606-XLE80E.

Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve. The catalog number covered on this page is 1606-XLE80E.

This string publishes a DC input window as well as an AC one. DC 110...300 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.

The feature flag on this row reads: remote shutdown input. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

Checks before substituting another 1606 number

The comparison that matters before a substitute is ordered is not the watts figure. It is whether the output matches the rail, whether the continuous current covers the load schedule with the published reserve left as inrush, whether the input frame matches the mains at the site, whether the terminals fit the existing wiring, and what the lifecycle category says about re-validating the panel. Two strings that agree on watts can disagree on all five. The catalog number covered on this page is 1606-XLE80E.

The published figures on this row are the ones a panel builder can be held to. They are also the ones that change when the string changes by a suffix, so a substitution made on the watts figure alone can move the terminals, the coating or the input frame without anyone noticing until the unit is on the bench. The catalog number covered on this page is 1606-XLE80E.

Questions this catalog number answers

What is 1606-XLE80E? 1606-XLE80E is a 1606-XLE Essential Power Supply in the Bulletin 1606 range: 24 V output at 3.3 A, 80 W, with AC 100...240 V input.

Is 1606-XLE80E current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.

What decides the input protection for 1606-XLE80E? The input current at the lowest voltage of the AC 100...240 V window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XLE80E the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Of the 129 1606 records carried here, these twelve stand closest to this catalog number. This page is 1606-XLE80E.

Site tree: the Allen Bradley Other PLC index carries 1606-XLE80E together with the other entries of the other-PLC group, which is where a catalogue walk usually starts. Reach it directly if the suffix on this record still needs confirming against a sibling.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)