Product Details:
Payment & Shipping Terms:
|
This page documents the 1606-XLE480EPC, a member of the Bulletin 1606 switched-mode power supply range (1606-XLE Essential Power Supply): 24 V output at 20 A, 480 W, with AC 100...240 V input. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.
| Attribute | Published value |
| Catalog number | 1606-XLE480EPC |
| Product family | 1606-XLE Essential Power Supply |
| Output voltage, nominal | 24 V |
| Output current, nominal | 20 A |
| Output power | 480 W |
| Input, AC | AC 100...240 V |
| Input, DC | DC 110...150 V |
| Feature or limitation flag | conformal coated (-XLE480EPC), spring clamps (-XLE480EL), push-in clamps (-XLE480EH), remote shutdown (-XLE480EM) |
| Position | Value | Meaning |
| Prefix | 1606 | Bulletin number for switched-mode power supplies |
| Series letters | XLE | 1606-XLE Essential Power Supply |
| Digits | 480 | rated output power in watts |
| Voltage letter | E | 24...28 V |
| Trailing suffix | PC | a suffix not in the published table; read the printed description |
The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.
| Series attribute | Published value |
| Series | 1606-XLE Essential Power Supply |
| Power range | 80...960 W |
| Overload / boost | 120 % power reserve |
| Reserve current | 20 % additional current |
| Efficiency, typical | 85.4...96.3 % typical depending on model |
| Operating temperature | -25...+70 degC on most models, 0...+70 degC on the regional 240 W units |
| Terminals | screw terminals as standard, spring and push-in variants in the same power class |
| Mains versions | single-phase 100...240 V AC, two-phase and three-phase 380...480 V AC versions |
The line exists for the reason printed against it: the cost-optimised line for panel builders who need a defined reserve without the XLS feature set. Against this string that means the 20 A output is one point inside a 80...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.
The rail load is the first number and it is 20 A; the second is the inrush the loads draw at switch-on, which the published reserve covers only for the time the line states; the third is the input current at the lowest point of the AC 100...240 V window, which is what the branch device has to carry without tripping on a cold start. A supply sized on nominal mains current alone fails the third check in winter.
A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLE480EPC, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.
Neighbouring numbers in the XLE series are 1606-XLE120B, 1606-XLE120E,1606-XLE120EC,1606-XLE120EL,1606-XLE120EH,1606-XLE120ED, 1606-XLE120E-2. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.
A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line. This entry is for 1606-XLE480EPC.
Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve. This entry is for 1606-XLE480EPC.
The -3 and regional suffixes are input variants. A trailing numeric suffix on this bulletin marks an input or regional variant rather than a different output: 380...480 V AC three-phase builds and regional mains builds read the same output current from a different input window. Substituting one for the other across a project is an input-side change, and the output side of the panel does not have to be re-validated. This entry is for 1606-XLE480EPC.
This string publishes a DC input window as well as an AC one. DC 110...150 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.
The feature flag on this row reads: conformal coated (-XLE480EPC), spring clamps (-XLE480EL), push-in clamps (-XLE480EH), remote shutdown (-XLE480EM). That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.
At 480 W this row sits in the high-power frames. Above roughly 480 W the terminals change to the larger screw or push-in sets and the unit needs the clearance a full-depth cabinet gives it, which is the mechanical difference a drawing has to show. A supply of this size also turns the enclosure thermal calculation into the deciding one, because the loss inside the cabinet is now tens of watts.
Four checks decide whether a different string can replace this one in an existing panel. Output voltage and rated current have to match the load, not merely exceed it, because a supply oversized on current derates differently at high ambient. The input window has to include the actual mains at the site, including the three-phase and regional builds that share an output with a single-phase frame. The terminal style has to fit the existing wiring, since screw, spring, push-in and plug connectors are not interchangeable in a cabinet that is already wired. And the lifecycle category has to be read before the part is ordered, because a direct replacement keeps the footprint while an engineering replacement moves it.
The published figures on this row are the ones a panel builder can be held to. They are also the ones that change when the string changes by a suffix, so a substitution made on the watts figure alone can move the terminals, the coating or the input frame without anyone noticing until the unit is on the bench. This entry is for 1606-XLE480EPC.
What is 1606-XLE480EPC? 1606-XLE480EPC is a 1606-XLE Essential Power Supply in the Bulletin 1606 range: 24 V output at 20 A, 480 W, with AC 100...240 V input.
Is 1606-XLE480EPC current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.
What decides the input protection for 1606-XLE480EPC? The input current at the lowest voltage of the AC 100...240 V window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.
No price and no lead time is implied on this page. For 1606-XLE480EPC the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.
Twelve of the 129 1606 records carried on this site, ordered by how close their codes sit to this one. This page is 1606-XLE480EPC.
This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 1606-XLE480EPC page is one entry in it.