Product Details:
Payment & Shipping Terms:
|
This page documents the 1606-XLDNET4, a member of the Bulletin 1606 switched-mode power supply range: no output voltage printed for this string output at 4 A, no output power printed, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.
| Attribute | Published value |
| Catalog number | 1606-XLDNET4 |
| Product family | Bulletin 1606 switched-mode power supply |
| Output voltage, nominal | no output voltage printed for this string |
| Output current, nominal | 4 A |
| Output power | no output power printed |
| Input, AC | not printed for this string |
| Input, DC | DC 24 V |
| Feature or limitation flag | DeviceNet DC-DC converter |
| Series attribute | Published value |
| Series | 1606-XL Power Supply (legacy line) |
| Power range | 60...960 W |
| Overload / boost | not published for this line in the current technical data |
| Reserve current | not published for this line in the current technical data |
| Efficiency, typical | not published for this line in the current technical data |
| Operating temperature | not published for this line in the current technical data |
| Terminals | screw terminals |
| Mains versions | single-phase 100...240 V AC and three-phase 380...480 V AC versions |
The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the 4 A output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.
The rail load is the first number and it is 4 A; the second is the inrush the loads draw at switch-on, which the published reserve covers only for the time the line states; the third is the input current at the lowest point of the published window, which is what the branch device has to carry without tripping on a cold start. A supply sized on nominal mains current alone fails the third check in winter.
A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLDNET4, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.
Neighbouring numbers to 1606-XLDNET4 in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.
Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve.
The -3 and regional suffixes are input variants. A trailing numeric suffix on this bulletin marks an input or regional variant rather than a different output: 380...480 V AC three-phase builds and regional mains builds read the same output current from a different input window. Substituting one for the other across a project is an input-side change, and the output side of the panel does not have to be re-validated.
Dc input is a separate application, not an ac fallback. The DC-input members of this bulletin take 110...300 V DC or a battery-range window, and they exist for rail, vehicle and battery-backed panels. A DC input is not an AC supply with a rectifier bolted on the front: the input window, the inrush and the branch protection all change, and the string carries the DC figure explicitly.
This string publishes a DC input window as well as an AC one. DC 24 V is the DC figure for this row, which is what a battery-backed or rail-fed panel is sized against. A DC feed does not carry the same inrush as an AC feed into a rectifier, and the branch device is selected from the DC current rather than from the AC current.
The feature flag on this row reads: DeviceNet DC-DC converter. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.
This string is a network or diagnostic accessory for the 24 V rail. It carries no output rating of its own and is selected by the rail it monitors or the segment it feeds. Accessories of this kind sit beside the supply in the same enclosure, so their current draw is part of the panel budget rather than part of the supply rating.
Four checks decide whether a different string can replace this one in an existing panel. Output voltage and rated current have to match the load, not merely exceed it, because a supply oversized on current derates differently at high ambient. The input window has to include the actual mains at the site, including the three-phase and regional builds that share an output with a single-phase frame. The terminal style has to fit the existing wiring, since screw, spring, push-in and plug connectors are not interchangeable in a cabinet that is already wired. And the lifecycle category has to be read before the part is ordered, because a direct replacement keeps the footprint while an engineering replacement moves it.
Read this row against the panel it will feed rather than against the catalogue page: the output is what the rail needs, the reserve is what the inrush may borrow, the efficiency is what the cabinet must dissipate, and the input window is what the site must supply. A number that satisfies the first three and fails the fourth is a unit that is correct on paper and unusable on a low-line branch.
What is 1606-XLDNET4? 1606-XLDNET4 is a switched-mode power supply in the Bulletin 1606 range: no output voltage printed for this string output at 4 A, no output power printed, with an input window printed in the selection table.
Is 1606-XLDNET4 current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.
What decides the input protection for 1606-XLDNET4? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.
This number is an accessory or a legacy-line member rather than a stand-alone supply row: DeviceNet DC-DC converter. Its own catalog string therefore carries the family and the function rather than an output rating, and it is selected by the supply it is paired with - the current rating of that supply, the rail it serves and the mounting it needs - instead of by a watts figure. That is why the selection row above marks the electrical fields the publication does not print for this catalog number.
No price and no lead time is implied on this page. For 1606-XLDNET4 the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.
Of the 129 1606 records carried here, these twelve stand closest to this catalog number. This page is 1606-XLDNET4.
Site tree: the Allen Bradley Other PLC index carries 1606-XLDNET4 together with the other entries of the other-PLC group, which is where a catalogue walk usually starts. The index sits one level above this page in the site tree.