This page documents the 1606-XLA, a member of the Bulletin 1606 switched-mode power supply range: no output voltage printed for this string output at no output current printed, no output power printed, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.
| Attribute | Published value |
| Catalog number | 1606-XLA |
| Product family | Bulletin 1606 switched-mode power supply |
| Output voltage, nominal | no output voltage printed for this string |
| Output current, nominal | no output current printed |
| Output power | no output power printed |
| Input, AC | not printed for this string |
| Input, DC | not printed for this string |
| Feature or limitation flag | Mounting bracket for direct wall or panel mounting without DIN rail |
| Series attribute | Published value |
| Series | 1606-XL Power Supply (legacy line) |
| Power range | 60...960 W |
| Overload / boost | not published for this line in the current technical data |
| Reserve current | not published for this line in the current technical data |
| Efficiency, typical | not published for this line in the current technical data |
| Operating temperature | not published for this line in the current technical data |
| Terminals | screw terminals |
| Mains versions | single-phase 100...240 V AC and three-phase 380...480 V AC versions |
The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the no output current printed output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.
Three calculations follow from the row above. The output load is the sum of everything on the rail against no output current printed, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the published window, not at nominal mains, because that is where the current is highest.
A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XLA, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.
Neighbouring numbers to 1606-XLA in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.
This string is listed as a mounting bracket: Mounting bracket for direct wall or panel mounting without DIN rail. It carries no output rating of its own, so it is selected by the supply it is paired with and by the mounting or load it serves, and the row above marks the electrical fields the publication does not print for it.
Efficiency is a thermal number before it is an energy number. A 90 to 95 percent efficiency figure on a 480 W supply leaves 25 to 48 W of heat inside the enclosure, which is the difference between a sealed cabinet that holds temperature and one that needs forced ventilation. The efficiency band is published per series rather than per model, so the number to check is the one for the frame size that was ordered.
Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current.
A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line.
The feature flag on this row reads: Mounting bracket for direct wall or panel mounting without DIN rail. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.
The comparison that matters before a substitute is ordered is not the watts figure. It is whether the output matches the rail, whether the continuous current covers the load schedule with the published reserve left as inrush, whether the input frame matches the mains at the site, whether the terminals fit the existing wiring, and what the lifecycle category says about re-validating the panel. Two strings that agree on watts can disagree on all five.
What this string fixes is narrower than it looks: the power stage, the output voltage and the input window. What the trailing characters add is mechanical and environmental, and what the lifecycle row adds is how much of the panel survives a replacement. Keeping those three groups apart is how a bill of materials stays readable after the first revision.
What is 1606-XLA? 1606-XLA is a switched-mode power supply in the Bulletin 1606 range: no output voltage printed for this string output at no output current printed, no output power printed, with an input window printed in the selection table.
Is 1606-XLA current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.
What decides the input protection for 1606-XLA? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.
This number is an accessory or a legacy-line member rather than a stand-alone supply row: Mounting bracket for direct wall or panel mounting without DIN rail. Its own catalog string therefore carries the family and the function rather than an output rating, and it is selected by the supply it is paired with - the current rating of that supply, the rail it serves and the mounting it needs - instead of by a watts figure. That is why the selection row above marks the electrical fields the publication does not print for this catalog number.
No price and no lead time is implied on this page. For 1606-XLA the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.
This page links twelve of the 129 1606 records on this site; the closest rating codes come first. This page is 1606-XLA.
For the surrounding range, open the Allen Bradley Other PLC catalogue index — 1606-XLA is listed there beside the rest of the other-PLC group. It is the entry point used when a project list is assembled group by group.