Product Details:
Payment & Shipping Terms:
|
This page documents the 1606-XL480EPT, a member of the Bulletin 1606 switched-mode power supply range: 24...28 V output at no output current printed, 480 W, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.
| Attribute | Published value |
| Catalog number | 1606-XL480EPT |
| Product family | Bulletin 1606 switched-mode power supply |
| Output voltage, nominal | 24...28 V |
| Output current, nominal | no output current printed |
| Output power | 480 W |
| Input, AC | not printed for this string |
| Input, DC | not printed for this string |
| Feature or limitation flag | legacy 1606-XL unit |
| Position | Value | Meaning |
| Prefix | 1606 | Bulletin number for switched-mode power supplies |
| Series letters | XL | the original XL line |
| Digits | 480 | rated output power in watts |
| Voltage letter | E | 24...28 V |
| Trailing suffix | PT | a suffix not in the published table; read the printed description |
The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.
| Series attribute | Published value |
| Series | 1606-XL Power Supply (legacy line) |
| Power range | 60...960 W |
| Overload / boost | not published for this line in the current technical data |
| Reserve current | not published for this line in the current technical data |
| Efficiency, typical | not published for this line in the current technical data |
| Operating temperature | not published for this line in the current technical data |
| Terminals | screw terminals |
| Mains versions | single-phase 100...240 V AC and three-phase 380...480 V AC versions |
The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the no output current printed output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.
Three calculations follow from the row above. The output load is the sum of everything on the rail against no output current printed, with the published reserve as the allowance for inrush rather than as continuous capacity. The heat inside the enclosure is the output power divided by the efficiency figure for this frame, and it is what a sealed cabinet has to dissipate. The input protection is sized from the input current at the lowest voltage of the published window, not at nominal mains, because that is where the current is highest.
A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XL480EPT, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.
Neighbouring numbers to 1606-XL480EPT in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.
A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line.
Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve.
The -3 and regional suffixes are input variants. A trailing numeric suffix on this bulletin marks an input or regional variant rather than a different output: 380...480 V AC three-phase builds and regional mains builds read the same output current from a different input window. Substituting one for the other across a project is an input-side change, and the output side of the panel does not have to be re-validated.
The feature flag on this row reads: legacy 1606-XL unit. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.
At 480 W this row sits in the high-power frames. Above roughly 480 W the terminals change to the larger screw or push-in sets and the unit needs the clearance a full-depth cabinet gives it, which is the mechanical difference a drawing has to show. A supply of this size also turns the enclosure thermal calculation into the deciding one, because the loss inside the cabinet is now tens of watts.
The comparison that matters before a substitute is ordered is not the watts figure. It is whether the output matches the rail, whether the continuous current covers the load schedule with the published reserve left as inrush, whether the input frame matches the mains at the site, whether the terminals fit the existing wiring, and what the lifecycle category says about re-validating the panel. Two strings that agree on watts can disagree on all five.
What this string fixes is narrower than it looks: the power stage, the output voltage and the input window. What the trailing characters add is mechanical and environmental, and what the lifecycle row adds is how much of the panel survives a replacement. Keeping those three groups apart is how a bill of materials stays readable after the first revision.
What is 1606-XL480EPT? 1606-XL480EPT is a switched-mode power supply in the Bulletin 1606 range: 24...28 V output at no output current printed, 480 W, with an input window printed in the selection table.
Is 1606-XL480EPT current? No lifecycle status is printed against this string in the source publication used for this page, so no availability claim is made here; the electrical figures are the ones the publication prints for the catalog number.
What decides the input protection for 1606-XL480EPT? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.
No price and no lead time is implied on this page. For 1606-XL480EPT the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.
Twelve of the 129 1606 records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 1606-XL480EPT.