Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR supplier

Large Image :  Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XL120DR / 1606XL120DR

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $206.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XL120DR

This page documents the 1606-XL120DR, a member of the Bulletin 1606 switched-mode power supply range: 24 V output at no output current printed, 120 W, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XL120DR
Product familyBulletin 1606 switched-mode power supply
Output voltage, nominal24 V
Output current, nominalno output current printed
Output power120 W
Input, ACnot printed for this string
Input, DCnot printed for this string
Feature or limitation flaglegacy 1606-XL unit
Lifecycle statusDiscontinued
Status dateDecember 31, 2020
Replacement categoryNo planned RA replacement
Replacement catalog numbernone printed

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLthe original XL line
Digits120rated output power in watts
Voltage letterD24 V
Trailing suffixRbuilt-in redundancy (decoupling diode or MOSFET)

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XL line

Series attributePublished value
Series1606-XL Power Supply (legacy line)
Power range60...960 W
Overload / boostnot published for this line in the current technical data
Reserve currentnot published for this line in the current technical data
Efficiency, typicalnot published for this line in the current technical data
Operating temperaturenot published for this line in the current technical data
Terminalsscrew terminals
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the no output current printed output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Lifecycle reading and what a substitute inherits

Rockwell lists this number as discontinued with a status date of December 31, 2020 and prints the replacement category as no planned ra replacement. That category matters more than the date: it says whether the panel keeps its wiring, its footprint or neither when the part is replaced, and a bill of materials that carries only the date is a bill of materials that finds out at the parts counter.

A discontinued string is still orderable only while distributor stock lasts, so the substitution decision belongs in the bill of materials while the machine is being specified rather than during a shutdown. The published electrical figures do not change on a discontinued number; the sourcing route does.

Load, heat and input protection

Sizing from this row means three numbers that are rarely written down together: the continuous rail load against no output current printed, the inrush allowance taken from the published reserve of the line, and the heat the unit leaves in the enclosure. The third one is the one that decides whether the cabinet needs a fan, and it follows from the efficiency band for this frame rather than from the watts figure alone. The input current at the lowest point of the published window is the fourth, and it is the one the branch device is sized against.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XL120DR, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers to 1606-XL120DR in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Derating above 60 degrees is a published curve, not a rule of thumb. The performance and essential lines run to 70 degrees C with derating above 60 degrees C, while the compact line carries its own window from -10 to 70 degrees C with -40 degrees C starting variants. A panel that runs at 55 degrees C has no derating to apply; one that runs at 65 has, and the published curve is what turns that into a usable output current.

A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line.

Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve.

The feature flag on this row reads: legacy 1606-XL unit. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

Checks before substituting another 1606 number

The comparison that matters before a substitute is ordered is not the watts figure. It is whether the output matches the rail, whether the continuous current covers the load schedule with the published reserve left as inrush, whether the input frame matches the mains at the site, whether the terminals fit the existing wiring, and what the lifecycle category says about re-validating the panel. Two strings that agree on watts can disagree on all five.

Read this row against the panel it will feed rather than against the catalogue page: the output is what the rail needs, the reserve is what the inrush may borrow, the efficiency is what the cabinet must dissipate, and the input window is what the site must supply. A number that satisfies the first three and fails the fourth is a unit that is correct on paper and unusable on a low-line branch.

Questions this catalog number answers

What is 1606-XL120DR? 1606-XL120DR is a switched-mode power supply in the Bulletin 1606 range: 24 V output at no output current printed, 120 W, with an input window printed in the selection table.

Is 1606-XL120DR current? Rockwell prints the status as discontinued with a status date of December 31, 2020, and the replacement category as no planned ra replacement with no replacement number printed.

What decides the input protection for 1606-XL120DR? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XL120DR the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

>

Related catalog numbers in the 1606 range

Of the 129 1606 records carried here, these twelve stand closest to this catalog number. This page is 1606-XL120DR.

Site tree: the Allen Bradley Other PLC index carries 1606-XL120DR together with the other entries of the other-PLC group, which is where a catalogue walk usually starts. Sibling codes of the same group are one click away from that page.