|
Product Details:
Payment & Shipping Terms:
|
This page documents the 1606-XL60D, a member of the Bulletin 1606 switched-mode power supply range: 24 V output at no output current printed, 60 W, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.
| Attribute | Published value |
| Catalog number | 1606-XL60D |
| Product family | Bulletin 1606 switched-mode power supply |
| Output voltage, nominal | 24 V |
| Output current, nominal | no output current printed |
| Output power | 60 W |
| Input, AC | not printed for this string |
| Input, DC | not printed for this string |
| Feature or limitation flag | legacy 1606-XL unit |
| Lifecycle status | Discontinued |
| Status date | April 04, 2018 |
| Replacement category | Direct Replacement |
| Replacement catalog number | 1606-XLP60EQ |
| Position | Value | Meaning |
| Prefix | 1606 | Bulletin number for switched-mode power supplies |
| Series letters | XL | the original XL line |
| Digits | 60 | rated output power in watts |
| Voltage letter | D | 24 V |
The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.
| Series attribute | Published value |
| Series | 1606-XL Power Supply (legacy line) |
| Power range | 60...960 W |
| Overload / boost | not published for this line in the current technical data |
| Reserve current | not published for this line in the current technical data |
| Efficiency, typical | not published for this line in the current technical data |
| Operating temperature | not published for this line in the current technical data |
| Terminals | screw terminals |
| Mains versions | single-phase 100...240 V AC and three-phase 380...480 V AC versions |
The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the no output current printed output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.
Rockwell lists this number as discontinued, with a status date of April 04, 2018 and a replacement category of direct replacement, pointing at 1606-XLP60EQ. The electrical figures on this page stay valid for the number itself; what the replacement category tells a panel builder is how much of the surrounding work carries over - a direct replacement is a swap in the same space with the same wiring, an engineering replacement moves terminals or footprint, and no planned replacement means the panel itself has to be re-thought.
A discontinued string is still orderable only while distributor stock lasts, so the substitution decision belongs in the bill of materials while the machine is being specified rather than during a shutdown. The published electrical figures do not change on a discontinued number; the sourcing route does.
Sizing from this row means three numbers that are rarely written down together: the continuous rail load against no output current printed, the inrush allowance taken from the published reserve of the line, and the heat the unit leaves in the enclosure. The third one is the one that decides whether the cabinet needs a fan, and it follows from the efficiency band for this frame rather than from the watts figure alone. The input current at the lowest point of the published window is the fourth, and it is the one the branch device is sized against.
A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XL60D, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.
Neighbouring numbers to 1606-XL60D in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.
A power supply is a branch-circuit load with its own protection. The supply needs a branch protective device sized from its input current at the lowest input voltage in the window, not at nominal mains. That is the number that decides the breaker, and a supply that trips a 10 A breaker on a 120 V branch is usually a device chosen on nominal current rather than on the low line.
Single-phase, two-phase and three-phase are different products. The same 24 V output appears on single-phase 100...240 V AC frames and on three-phase 380...480 V AC frames. They are not interchangeable on a panel: the three-phase units exist where the load is too large for a single-phase branch, and each frame carries its own terminal layout and its own derating curve.
The -3 and regional suffixes are input variants. A trailing numeric suffix on this bulletin marks an input or regional variant rather than a different output: 380...480 V AC three-phase builds and regional mains builds read the same output current from a different input window. Substituting one for the other across a project is an input-side change, and the output side of the panel does not have to be re-validated.
The feature flag on this row reads: legacy 1606-XL unit. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.
Four checks decide whether a different string can replace this one in an existing panel. Output voltage and rated current have to match the load, not merely exceed it, because a supply oversized on current derates differently at high ambient. The input window has to include the actual mains at the site, including the three-phase and regional builds that share an output with a single-phase frame. The terminal style has to fit the existing wiring, since screw, spring, push-in and plug connectors are not interchangeable in a cabinet that is already wired. And the lifecycle category has to be read before the part is ordered, because a direct replacement keeps the footprint while an engineering replacement moves it.
The published figures on this row are the ones a panel builder can be held to. They are also the ones that change when the string changes by a suffix, so a substitution made on the watts figure alone can move the terminals, the coating or the input frame without anyone noticing until the unit is on the bench.
What is 1606-XL60D? 1606-XL60D is a switched-mode power supply in the Bulletin 1606 range: 24 V output at no output current printed, 60 W, with an input window printed in the selection table.
Is 1606-XL60D current? Rockwell prints the status as discontinued with a status date of April 04, 2018, and the replacement category as direct replacement pointing at 1606-XLP60EQ.
What decides the input protection for 1606-XL60D? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.
No price and no lead time is implied on this page. For 1606-XL60D the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.
For the surrounding range, open the Allen Bradley Other PLC catalogue index — 1606-XL60D is listed there beside the rest of the other-PLC group. Reach it directly if the suffix on this record still needs confirming against a sibling.