Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier Allen Bradley Power Supply 1606-XL180B / 1606XL180B supplier

Large Image :  Allen Bradley Power Supply 1606-XL180B / 1606XL180B

Product Details:

Place of Origin: Made in China
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Power Supply 1606-XL180B / 1606XL180B

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $300.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Paypal and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1606-XL180B

This page documents the 1606-XL180B, a member of the Bulletin 1606 switched-mode power supply range: 12 V output at no output current printed, 180 W, with an unprinted input window. The selection and specification figures below are quoted from Rockwell publication 1606-TD002, which prints them per catalog number or per model row.

Selection row for this catalog number

AttributePublished value
Catalog number1606-XL180B
Product familyBulletin 1606 switched-mode power supply
Output voltage, nominal12 V
Output current, nominalno output current printed
Output power180 W
Input, ACnot printed for this string
Input, DCnot printed for this string
Feature or limitation flaglegacy 1606-XL unit
Lifecycle statusDiscontinued
Status dateOctober 30, 2017
Replacement categoryDirect Replacement
Replacement catalog number1606-XLS180B

How this string is built

PositionValueMeaning
Prefix1606Bulletin number for switched-mode power supplies
Series lettersXLthe original XL line
Digits180rated output power in watts
Voltage letterB12 V

The rule to carry into a bill of materials check is that the digits are watts and the letter after them is the output voltage, so two strings that differ only in the trailing characters share the power stage and differ in input window, terminal style or coating. A substitution across those characters is a mechanical or environmental decision rather than an electrical one, and the replacement category in the row above tells which kind of re-validation it needs.

Where this model sits in the XL line

Series attributePublished value
Series1606-XL Power Supply (legacy line)
Power range60...960 W
Overload / boostnot published for this line in the current technical data
Reserve currentnot published for this line in the current technical data
Efficiency, typicalnot published for this line in the current technical data
Operating temperaturenot published for this line in the current technical data
Terminalsscrew terminals
Mains versionssingle-phase 100...240 V AC and three-phase 380...480 V AC versions

The line exists for the reason printed against it: the first generation of Bulletin 1606 that the XLE and XLS lines replaced part by part. Against this string that means the no output current printed output is one point inside a 60...960 W range, and the reserve and boost figures belong to the whole line, so a load sized on the continuous rating plus the published reserve is a load the line is designed to carry rather than one it tolerates.

Lifecycle reading and what a substitute inherits

Rockwell lists this number as discontinued, with a status date of October 30, 2017 and a replacement category of direct replacement, pointing at 1606-XLS180B. The electrical figures on this page stay valid for the number itself; what the replacement category tells a panel builder is how much of the surrounding work carries over - a direct replacement is a swap in the same space with the same wiring, an engineering replacement moves terminals or footprint, and no planned replacement means the panel itself has to be re-thought.

A discontinued string is still orderable only while distributor stock lasts, so the substitution decision belongs in the bill of materials while the machine is being specified rather than during a shutdown. The published electrical figures do not change on a discontinued number; the sourcing route does.

Load, heat and input protection

Sizing from this row means three numbers that are rarely written down together: the continuous rail load against no output current printed, the inrush allowance taken from the published reserve of the line, and the heat the unit leaves in the enclosure. The third one is the one that decides whether the cabinet needs a fan, and it follows from the efficiency band for this frame rather than from the watts figure alone. The input current at the lowest point of the published window is the fourth, and it is the one the branch device is sized against.

A supply is a branch-circuit load with its own protection and its own inrush. On 1606-XL180B, choosing the breaker on the nominal input current is the mistake that shows up as a nuisance trip on a cold morning, when the input voltage is low and the bulk capacitors are empty.

Other strings in the same series

Neighbouring numbers to 1606-XL180B in the XL series are 1606-XLB120E, 1606-XLB240E, 1606-XLB36EH. They differ in rated watts, output voltage or input frame rather than in construction, so the selection between them is made on load and on the mains available at the panel.

Terminals decide the wiring time more than the rating does. Spring terminals, screw terminals, push-in terminals and plug connectors all appear on this bulletin at the same power class. The terminal style is chosen by how the panel is wired and by whether the unit is expected to be swapped on site, and it is part of the catalog string rather than a build option added later.

Lifecycle status changes the spare, not the specification. A discontinued string keeps its published electrical figures; what changes is the path Rockwell prints for it: direct replacement, engineering replacement with different mounting or wiring, or no planned replacement. The replacement category is the amount of re-validation work a panel inherits, and it is the reason a bill of materials is read with the lifecycle column next to the rating.

Efficiency is a thermal number before it is an energy number. A 90 to 95 percent efficiency figure on a 480 W supply leaves 25 to 48 W of heat inside the enclosure, which is the difference between a sealed cabinet that holds temperature and one that needs forced ventilation. The efficiency band is published per series rather than per model, so the number to check is the one for the frame size that was ordered.

The feature flag on this row reads: legacy 1606-XL unit. That flag is the field that separates this number from its neighbours of the same wattage and voltage, and it is the one to read first in a substitution, because a supply that differs only in its flag differs in mounting, terminals or output limitation rather than in power.

Checks before substituting another 1606 number

A substitution audit for this number runs in a fixed order: output voltage, then continuous current against the load schedule, then the input frame actually present at the site, then the terminal style, and last the lifecycle category. Any one of the five can invalidate a part that looks correct in a catalogue row, and the cheapest place to catch it is the bill of materials rather than the parts counter during a shutdown.

Read this row against the panel it will feed rather than against the catalogue page: the output is what the rail needs, the reserve is what the inrush may borrow, the efficiency is what the cabinet must dissipate, and the input window is what the site must supply. A number that satisfies the first three and fails the fourth is a unit that is correct on paper and unusable on a low-line branch.

Questions this catalog number answers

What is 1606-XL180B? 1606-XL180B is a switched-mode power supply in the Bulletin 1606 range: 12 V output at no output current printed, 180 W, with an input window printed in the selection table.

Is 1606-XL180B current? Rockwell prints the status as discontinued with a status date of October 30, 2017, and the replacement category as direct replacement pointing at 1606-XLS180B.

What decides the input protection for 1606-XL180B? The input current at the lowest voltage of the printed window, not the nominal mains figure, because that is where the branch current peaks and where a breaker chosen on nominal current trips on a cold start.

No price and no lead time is implied on this page. For 1606-XL180B the selection, series and lifecycle figures are quoted from Rockwell publication 1606-TD002 and the published catalog number explanation; a field the publication does not print for this string is marked as such rather than estimated from a neighbouring model.

For the surrounding range, open the Allen Bradley Other PLC catalogue index — 1606-XL180B is listed there beside the rest of the other-PLC group. It is the entry point used when a project list is assembled group by group.