logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 20BP140A3ANNANC0

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 20BP140A3ANNANC0

China Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier
Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier Allen Bradley PowerFlex 20BP140A3ANNANC0 supplier

Large Image :  Allen Bradley PowerFlex 20BP140A3ANNANC0

Product Details:

Place of Origin: Made in MEXICO
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 20BP140A3ANNANC0

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $5800.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 2 PCS
Detailed Product Description

20BP140A3ANNANC0 technical data PDF download 20BP140A3ANNANC0 PowerFlex 700 140 A, 540 V DC

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PowerFlex 700 drives

20BP140A3ANNANC0 is a PowerFlex 700 drive, catalog code b=P: 540 V DC input (Y), pre-charge.

The three digits after the voltage letter are the output current in amps - here 140 A. Published ratings: 75 kW normal duty, 55 kW heavy duty, frame 5.

Quick answer. 20BP140A3ANNANC0 is a PowerFlex 700 drive, 540 V DC, normal duty, frame 5, A - IP 20, NEMA/UL Type 1, with conformal coating.

  • Normal duty output current:
  • Motor rating:
  • Frame: 5
  • Enclosure: A - IP 20, NEMA/UL Type 1, with conformal coating
  • Communication slot: N - None
  • Control and I/O: C - Vector control, 24 V DC I/O
20BP260A0AYNANC0 260 A, 540 V DC IN STOCK
20BP260A0ANNANC0 260 A, 540 V DC IN STOCK
20BP205A3ANNANC0 205 A, 540 V DC IN STOCK
20BP205A0ANNANC0 205 A, 540 V DC IN STOCK
20BP170A0AYNANC0 170 A, 540 V DC IN STOCK
20BP170A0ANNANC1 170 A, 540 V DC IN STOCK
20BP170A0ANNANC0 170 A, 540 V DC IN STOCK
20BP140A3ANNANC0 140 A, 540 V DC IN STOCK
20BP730N0NNNNNC0 730 A, 540 V DC IN STOCK
20BP535U0ANNNNC0 535 A, 540 V DC IN STOCK
20BP535N0NNNNNC0 535 A, 540 V DC IN STOCK
20BP481N0NNNNNC0 481 A, 540 V DC IN STOCK
20BP365A0ANNNNC0 365 A, 540 V DC IN STOCK
20BP325A0ANNNNC0 325 A, 540 V DC IN STOCK
20BP292N0NNNNNC0 292 A, 540 V DC IN STOCK
20BP292A0ANNNNC0 292 A, 540 V DC IN STOCK
20BP260A3ANNANC0 260 A, 540 V DC IN STOCK
20BP205A0AYNANC0 205 A, 540 V DC IN STOCK
20BP140A0AYNANC0 140 A, 540 V DC IN STOCK
20BP140A0ANNANC0 140 A, 540 V DC IN STOCK
20BP125A0AYNANC0 125 A, 540 V DC IN STOCK
20BP105A0AYNANC0 105 A, 540 V DC IN STOCK
20BP105A0ANNANC1 105 A, 540 V DC IN STOCK
20BP105A0ANNANC0 105 A, 540 V DC IN STOCK

Product Specifications 20BP140A3ANNANC0 (PDF)
 Catalog number
 20BP140A3ANNANC0
 Voltage rating (b)
 P - 540 V DC input (Y), pre-charge
 Output current rating (c)
 140 A
 Normal duty rating
 75 kW
 Heavy duty rating
 55 kW
 Frame size
 5
 Enclosure (d)
 A - IP 20, NEMA/UL Type 1, with conformal coating
 HIM (e)
 3 - LCD display, full numeric keypad
 Documentation (f)
 A - Manual included
 Brake IGBT (g)
 N - No brake IGBT
 Internal braking resistor (h)
 N - No internal braking resistor
 Emission class (i)
 A - CE filter fitted, CM choke fitted
 Comm slot (j)
 N - None
 Control and I/O (k)
 C - Vector control, 24 V DC I/O
 Feedback (l)
 0 - No feedback
 Rating code
 140 - read as the output current in amps
 Source
 20B-TD001 p.6-7 catalog explanation; rating and frame from the Rockwell product page

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 20B-TD001 (Sept 2023) (module specifications) and 20B-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

20BP140A3ANNANC0 20BP140A3ANNANC0 20BP140A3ANNANC0 20BP140A3ANNANC0 20BP140A3ANNANC0 20BP140A3ANNANC0 20BP140A3ANNANC0

How to read this catalog number

The string is 20B (drive), P (voltage), 140 (output current in amps), then nine option positions d to l.

Here: d=A, e=3, f=A, g=N, h=N, i=A, j=N, k=C, l=0.

Two more positions m and n exist for future use and special firmware; they are omitted on most orders.

What each position controls

Enclosure (d): IP 20, NEMA/UL Type 1, with conformal coating.

HIM (e): LCD display, full numeric keypad. Remote HIM codes J and K mount on a panel door and need the stand-alone IP 54 enclosure.

Brake IGBT (g): No brake IGBT. Internal braking resistor (h): No internal braking resistor; Rockwell does not offer the internal resistor on frame 3 and larger.

Emission (i): CE filter fitted, CM choke fitted. Comm slot (j): None. Control and I/O (k): Vector control, 24 V DC I/O. Feedback (l): No feedback.

DC input instead of an AC front end

A 540 V DC input PowerFlex 700 takes its power from a common DC bus instead of a three-phase rectifier.

Pre-charge is in the catalog code (the Y in position b), so the drive expects the DC bus to be brought up by the line-side pre-charge circuit rather than by the drive itself.

This is the difference an engineer checks first: a 20BP is not a drop-in replacement for a 20BD fed from 480 V AC.

What to verify before buying used

Nameplate catalog number, all 16 characters, against this page.

Whether the frame 5 or 6 enclosure is present; open/flange (d=F) and stand-alone (d=G) drives are the same chassis in different packaging.

Encoder board presence (l=1) and the brake IGBT (g=Y), because both are separate hardware, not parameters.

Documented source

For 20BP140A3ANNANC0 the positions, voltage classes and option codes are transcribed from 20B-TD001 (September 2023), Catalog Number Explanation, pages 6 and 7, and cross-checked against 20B-UM001 page P-5.

Current, power and frame figures for 20BP140A3ANNANC0 are taken from the product page for this catalog number; where that page carries no power rating, none is shown here.

FAQ — 20BP140A3ANNANC0

What is 20BP140A3ANNANC0?

PowerFlex 700 drive, 540 V DC input (Y), pre-charge, 140 A output.

What is the output current of 20BP140A3ANNANC0?

140 A.

What does the P code mean?

540 V DC input (Y), pre-charge.

Does 20BP140A3ANNANC0 have a communication option?

None.

What enclosure is 20BP140A3ANNANC0?

IP 20, NEMA/UL Type 1, with conformal coating.

Related catalog numbers in the same rating code as 20BP140A3ANNANC0. Same A power stage, different option string - the enclosure, HIM, communication and safety positions are what change between them.

20BP260A0AYNANC0 (260 A, 540 V DC) · 20BP260A0ANNANC0 (260 A, 540 V DC) · 20BP205A3ANNANC0 (205 A, 540 V DC) · 20BP205A0ANNANC0 (205 A, 540 V DC) · 20BP170A0AYNANC0 (170 A, 540 V DC) · 20BP170A0ANNANC1 (170 A, 540 V DC) · 20BP170A0ANNANC0 (170 A, 540 V DC) · 20BP730N0NNNNNC0 (730 A, 540 V DC) · 20BP535U0ANNNNC0 (535 A, 540 V DC)


Data sources. For 20BP140A3ANNANC0, decoded from Rockwell 20B-TD001 p.6-7 Catalog Number Explanation; rating and frame from the product page for this catalog number. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

20BP140A3ANNANC0

This page documents catalog number 20BP140A3ANNANC0, a PowerFlex 700 DC input drive with the 540 V DC precharge build, as published by Rockwell Automation in publication 20B-TD001 and the product data for this catalog number. Every value below comes from those documents; nothing is inferred.

Rating for this catalog number

SpecificationValue
Output current, normal duty140 A
Normal duty rating75 kW
Heavy duty rating55 kW
Frame5
Input voltage rating540 V DC, with internal precharge
Voltage code in catalog numberP = 540 V DC
Input phasesDC bus, no AC rectifier stage
Output phases3
Output voltage range0 V to rated motor voltage
Intermittent overload110% for up to 1 min, 150% for up to 3 s
Instantaneous overcurrent trip220...300% of rated current, rating dependent
Current limit setting range20...160% of rated output current
Efficiency97.5% at rated amps, nominal line volts
Power ride-through15 ms at full load
Short circuit rating200,000 A symmetrical
Drive to motor power ratioNot greater than 2:1, not less than 1:2
Analog inputs / outputs2 / 2
Digital inputs / outputs6 / 3
EnclosureIP20, NEMA/UL Type 1, with conformal coating
Ambient temperature0...50 °C (frames 5...6, most ratings, top label in place)
Altitude1000 m (3300 ft) without derating
Sound levelFrame 5: 71 dB @ 200 CFM fan velocity
Height, standalone IP54 build1574.8 mm
Width, standalone IP54 build609.6 mm
Depth, standalone IP54 build450.7 mm
Power terminal capacity, frame 550.0 mm² (1 AWG) max, 4.0 mm² (8 AWG) min, torque per terminal label
Brake and PE terminal capacity150.0 mm² (300 MCM) max, 2.5 mm² (14 AWG) min, 6.0 N·m (52 lb·in)

What the option string says

The catalog number is a readable specification once each position is decoded against the bulletin catalog explanation. For this unit the positions read as follows:

SpecificationValue
Position in catalog numberPublished meaning
Enclosure code AIP20, NEMA/UL Type 1, with conformal coating
HIM code 3LCD display, full numeric keypad
Documentation code Amanual supplied
Brake code Nno brake IGBT
Resistor code Nno drive mounted brake resistor
Emission code ACE filter and common mode choke fitted
Communication code Nno communication module
Control code Cvector control with 24 V DC I/O
Feedback code 0no encoder feedback

Consequences on site

The frame number decides the mechanical work. A frame 5 unit and a frame 6 unit differ in height, width, depth, terminal capacity and airflow, so a replacement that moves up a frame changes the mounting plate, the duct length and the cabinet vent free area. That is why the frame is listed next to the amp code on this page rather than buried in a dimension drawing.

The frame number decides the mechanical work. A frame 5 unit and a frame 6 unit differ in height, width, depth, terminal capacity and airflow, so a replacement that moves up a frame changes the mounting plate, the duct length and the cabinet vent free area. That is why the frame is listed next to the amp code on this page rather than buried in a dimension drawing.

Precharge is built in on this build, which means the unit expects to be connected to a live bus through its own charging path before the main contactor closes. Where the panel is wired with a single disconnector to the bus, the auxiliary contact that proves precharge complete is a wiring item, not a parameter: the control sequence has to be told the bus is up, and a drive that closes onto a partly charged bus draws the current step that the precharge circuit exists to prevent.

Scope of the published data

Only values that appear in 20B-TD001, 20B-IN014 or the Rockwell Automation product data for this catalog number are printed here. Where a figure is not published for this amp code, the table does not carry a substitute: the heavy duty kW row is present only for the codes whose product data states it, and DC input current, radiated emissions class and enclosure dimensions for the AC build are not adopted from other frames or other voltage classes. A missing row means the document is silent, not that the value is zero.

Ambient temperature on frames 5 and 6 is quoted as 0 to 50 degrees C for most ratings with the top label in place, and the wording matters: the label is part of the thermal design and removing it changes the rating rather than merely voiding a warranty. Altitude is quoted to 1000 m without derating, so a site above that figure has to apply the published derating curve before the amp code is chosen. Neither of these limits appears on the motor nameplate, which is why they are missed.

The instantaneous overcurrent trip sits above the intermittent rows, at 220 to 300 percent of rated current depending on the rating itself. That band is not a fault level, it is a protection threshold: a short circuit or a flashover in the motor leads pushes the output stage past it in microseconds and the drive shuts down before the module is destroyed. What matters on site is that the threshold moves with the rating, so a replacement drive of a different amp code does not protect the same way, and the motor circuit protector upstream has to be coordinated with the new figure rather than the old one.

Vector control with 24 V DC I/O is the standard configuration in this range, and the position that carries it also decides what the terminal strip looks like. Twenty-four volt control is what most cabinets in Europe and North America already distribute, so a drive wired for it shares the same supply as the safety relay and the pilot devices; a 115 V AC control build exists for plants that still run that voltage, and mixing the two inside one panel means two control supplies, two fuse groups and a labelling exercise that nobody wants during a shutdown.

A replacement schedule is built from three facts that are easy to keep and hard to reconstruct: the catalog string as printed on the label, the power code inside it, and the frame the unit was built on. The suffix letters describe what is fitted, so two drives with the same amp code but different letters are not interchangeable without reading the panel drawing. Recording the full string, rather than the shortened number used in conversation, is what makes a purchase order unambiguous and what lets a spare be ordered years later without a site visit.

Precharge is the part of a common-bus installation that damages hardware when it is treated as an afterthought. A DC bus carries a large capacitor bank across every inverter connected to it, so closing a disconnector onto an uncharged bus produces a current step limited only by wiring resistance. Drives built with an internal precharge circuit ramp that capacitor bank up before the main contactor closes; drives built without one need an external precharge path, an interlock that proves the bus is up, and a control sequence that will not permit the contactor to close early. The difference between the two build styles is a catalog position, and it is worth reading that position rather than assuming.

DC bus terminals change the wiring rules. The input terminals on these units accept DC+ and DC- alongside a brake resistor pair and a protective earth, and the conductor sizes quoted per frame are terminal block capacity, not a recommendation. A common-bus installation also has to decide what happens to the bus when one inverter trips: a drive that faults and stops drawing current leaves the bus charged, and a maintenance person who opens a disconnector without a proven discharge path is the real hazard in the system, not the drive.

An encoder feedback option changes the control architecture rather than just adding a connector. With feedback the drive can close a speed or position loop and hold torque at low speed, which is what a lift, a winder or a positioning axis needs; without it the drive runs open loop on a calculated slip model, which is adequate for fans and pumps and wrong for anything that has to hold a load at zero speed. The encoder supply on this option is 12 V at 250 mA with a differential receiver rated to 250 kHz, so the encoder chosen has to match that interface rather than the other way round.

The difference between a drive that lasts fifteen years and one that fails in three is often the fan and the filter, not the power stage. Fan velocity is published, filter builds are published, and both are serviceable items with a replacement interval; a maintenance schedule that ignores them turns a thermal margin into a thermal failure at the worst possible moment. Publishing the airflow figure with the sound level is the manufacturer's way of saying the cooling is specified, and a panel builder who reads it can size the cabinet vents instead of guessing.

A published efficiency of 97.5 percent at rated amps and nominal line volts sounds like a marketing number until it is turned into heat. Three percent of a 132 kW rating is roughly four kilowatts of loss inside an enclosure that also holds contactors, a PLC and a 24 V supply. That heat has to leave through the cabinet surface or through forced ventilation, and the fan velocity quoted with the sound level figure is the clue: at 200 CFM on frame 5 and 300 CFM on frame 6 the airflow is specified, not optional, and a cabinet built without that airflow will run the drive into its ambient limit on a warm afternoon.

A blank cover instead of a keypad is a deliberate choice, not a stripped unit. In a networked installation the parameters live in the controller and are downloaded on start-up, so a local operator interface adds a place where somebody can change a value that the program will overwrite at the next power cycle. Where commissioning, troubleshooting or local speed control is part of the job, the full numeric keypad version exists in the same catalog string, and the only difference between the two is one character after the enclosure code.

Common-bus architectures survive in plants where several motors accelerate and decelerate together, because one motor's regenerated energy can feed another's acceleration instead of a resistor. The price of that architecture is that the bus becomes a shared asset: one inverter's fault, one loose DC terminal or one undersized precharge path affects every drive connected to it. Documentation of the bus, the discharge path and the precharge interlock belongs with the panel drawing, and a drive page that publishes the DC terminal sizes, the precharge build and the frame is part of that documentation.

The overload figures on a drive datasheet are two different promises. The continuous rating is what the module can deliver indefinitely at the published ambient; the intermittent rows, 110 percent for up to one minute and 150 percent for up to three seconds, describe what the output stage will do during an acceleration or a load step and how long it will keep doing it before the current limit folds back. Sizing to the intermittent row instead of the continuous row is how a drive ends up tripping on a conveyor that starts loaded every morning; the continuous row, with the ambient derating applied, is the one that matches a motor nameplate.

Brake IGBT and brake resistor are two separate catalog positions, and the reason is that they serve different jobs. The transistor switches the energy that the motor returns during a deceleration into a resistor; the resistor absorbs it as heat. A drive ordered with the transistor but without the internal resistor expects an external resistor sized for the duty cycle of the actual load, and one ordered with neither expects the deceleration to be handled by the mechanical system or by returning energy to the bus. Fitting an internal resistor on a frame where the option is not offered is not a field modification, it is a different product.

Catalog numbers, options and spare parts for the same PowerFlex 700 range are listed in the Drives & Motors category. This drive itself can be checked against the shop listing at 20BP140A3ANNANC0.

This part sits in the Allen-Bradley PowerFlex drives and motors category, with the other models and spare parts listed alongside it.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)