Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 20BW098A0ANNANC0, a PowerFlex 700 drive in the 932 V DC input class. The decode and the class definitions come from the drive family's published catalog number explanation and voltage table; the option region is interpreted only where the family publishes a rule for it.
| Specification | Value |
|---|---|
| Catalog number | 20BW098A0ANNANC0 |
| Family (first three characters) | 20B - PowerFlex 700 |
| Input class | W - 932 V DC, precharge Y |
| Rating code | 098 - 098 A |
| Enclosure field | A - IP20, NEMA/UL Type 1 |
| Brake field as ordered | N - no brake IGBT |
| Brake field | Y fitted / N not fitted; standard on frames 0-3, optional on frames 4-6 |
| Highest DC class on this platform | 932 V DC, once above 810 V DC |
| AC class at the same bus level | 690 V AC three-phase, by the 1.35 arithmetic labelled on this page |
| Published rating block for this class | ND and HD horsepower and kW per frame, in the DC input block, 932 V column |
| Not quoted on this page | kW and frame pairing for this string, because only the 932 V column can supply it |
Two listings carry this 98 A rating in the 932 V DC class, and they differ in a single character that the family publishes a rule for. This page documents the one without the brake. The string reads 20B for PowerFlex 700, W for 932 V DC, 098 for the output current, A for the enclosure field, and N where the brake field sits.
The brake field is the only option character that can be read without ambiguity here, because the published table maps Y and N directly to brake IGBT fitted or not, with the brake standard on frames 0 to 3 and optional on frames 4 to 6. N therefore means this drive is ordered without a brake IGBT, which on a common bus means its regenerative energy goes back to the bus rather than into a resistor.
Precharge belongs to the class letter and not to the option block. W is published with precharge Y, so this drive carries its own charging path for its DC link. That makes it suitable for connection to a live bus without an external charging arrangement sized for the drive, while leaving the panel's energisation sequence and the fault coordination as system responsibilities.
The class voltage is the highest DC level in the family and the correspondence to AC is arithmetic rather than a published statement: 1.35 times 690 V is about 931 V, so 932 V DC is the direct-current counterpart of the 690 V AC class. That arithmetic is the reason a 690 V installation can be described in either vocabulary without changing what the bus actually is.
The rating code reads as 098, which is 98 amps under the family's convention of three characters for normal-duty amps. The reading does not depend on the class letter, so the string has to be read in parts rather than by pattern.
Where the published DC block gives horsepower and kW per frame for each of the five DC voltages, this page does not quote a kW for this string. The 932 V column of that block is the only defensible source, and a copy from a neighbouring column would be an inference rather than a quotation.
The enclosure field A is IP20 and NEMA/UL Type 1, with F and G covering open and flange mounting and stand-alone wall mounting. On a DC-fed installation the cabinet also carries the bus bars, the charging arrangement and the protection coordination, so the enclosure code describes the drive's own protection and not the installation's.
The distinction between this string and its twin is not cosmetic. A panel designed for a braked section and fitted with an unbraked one will see the deceleration energy arrive on the bus instead of in a resistor, and the first symptom is an overvoltage fault during a stop rather than anything mechanical. The option character is the only place that difference is recorded.
The terminal documentation applies as it does to any drive in the class: the larger frames publish input power, DC+, DC-, BR1, BR2, PE and the motor connections as one group with wire ranges and torques per frame. The DC pair carries the bus continuously and the torque figure is part of the maintenance schedule rather than a one-off installation value.
The option characters after the brake field carry the communication slot, control type, feedback and documentation and are not interpreted here. Where two strings differ only in the option region, the safe statement is that what is fitted differs, not that the rating differs.
No lifecycle statement and no price is implied. Class and precharge definitions, the brake rule, the rating-code convention, the enclosure field and the terminal grouping are quoted from the drive family's published documentation; the bus arithmetic is labelled as arithmetic.
The other drives, reactors and drive spares in this range are collected in the Drives & Motors category. Codes documented alongside this one are 20BW052A0ANNANC0, 20BW098A0AYNANC0, 20BW142A0ANNANC0, 20BF119A0ANNANC0, and this drive is listed at 20BW098A0ANNANC0.
The fourth character of a 20B catalog number is the voltage code, and there are twelve of them: five AC classes and seven DC-bus classes. They are not interchangeable, they do not share frame ranges, and the DC codes additionally split on whether a pre-charge circuit is built in. This table is the complete code list from the 20B-TD001 catalog explanation, with the frame range each class is built on.
| Code | Voltage rating | Frames built on | Where the class is used |
| B | 240 V AC, 3-phase, 50/60 Hz | 0-6 | 208...240 V supply, the North American low-voltage class |
| C | 400 V AC, 3-phase, 50/60 Hz | 0-6 | 380...415 V supply, the European standard class |
| D | 480 V AC, 3-phase, 50/60 Hz | 0-6 | 440...480 V supply, the widest rating ladder of the series |
| E | 600 V AC, 3-phase, 50/60 Hz | 0-6 | 575...600 V supply, Canada and heavy industry |
| F | 690 V AC, 3-phase, 50/60 Hz | 5-6 | 690 V supply, and only on the larger frames |
| H | 540 V DC input, pre-charge | 5-6 | fed from a 540 V DC bus, pre-charge circuit built in |
| J | 650 V DC input | 5-6 | 650 V DC common DC bus, no pre-charge letter |
| N | 325 V DC input (Y), pre-charge | 5-6 | 325 V DC bus, common-bus configuration |
| P | 540 V DC input (Y), pre-charge | 5-8 | 540 V DC common bus, the widest DC frame range |
| R | 650 V DC input (Y), pre-charge | 5-8 | 650 V DC common bus, frames 5 through 8 |
| T | 810 V DC input (Y), pre-charge | 5-6 | 810 V DC bus for 600 V class front ends |
| W | 932 V DC input (Y), pre-charge | 5-6 | 932 V DC bus for 690 V class front ends |
Where this page sits: The fourth character of 20BW098A0ANNANC0 is W: 932 V DC input (Y), pre-charge, frames 5-6 in the catalog explanation, with 098 A in the rating field.
What is missing here is the ladder itself: the rating tables that turn these codes into amp, power and frame steps are printed per voltage class in 20B-TD001, and only the 240, 400 and 480 V classes were transcribed for this site. For 600 V, 690 V and the DC-bus classes the neighbouring current steps are therefore not listed, and none is inferred from another class.
Catalog prefix first: 20B is the PowerFlex 700 prefix and 20A is the PowerFlex 70 prefix. A page filed under a "PowerFlex 70 drives" group while carrying a 20B number is a filing error at the prefix level - the two are different product lines with different frame ranges, not variants of one another. The catalog number on the page decides, not the group label.
Source: 20B-TD001 PowerFlex 700 catalog number explanation (voltage, rating and frame codes) and the 20B-TD001 rating tables. Values are quoted as printed; no figure on this page is calculated or extrapolated.