Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 20BW052A0ANNANC0, a PowerFlex 700 drive in the 932 V DC input class. The decode and the class definitions come from the drive family's published catalog number explanation and voltage table; the option region is interpreted only where the family publishes a rule for it.
| Specification | Value |
|---|---|
| Catalog number | 20BW052A0ANNANC0 |
| Family (first three characters) | 20B - PowerFlex 700 |
| Input class | W - 932 V DC, precharge Y |
| Rating code | 052 - 052 A |
| Enclosure field | A - IP20, NEMA/UL Type 1 |
| Brake field as ordered | N - no brake IGBT |
| Brake field | Y fitted / N not fitted; standard on frames 0-3, optional on frames 4-6 |
| Highest DC class on this platform | 932 V DC, once above 810 V DC |
| AC class at the same bus level | 690 V AC three-phase, by the 1.35 arithmetic labelled on this page |
| Published rating block for this class | ND and HD horsepower and kW per frame, in the DC input block, 932 V column |
| Not quoted on this page | kW and frame pairing for this string, because only the 932 V column can supply it |
This string sits in the highest direct-current class the family publishes, and that class is the one where the arithmetic between AC and DC becomes visible. The string reads 20B for PowerFlex 700, W for 932 V DC, 052 for the output current in amps on the rating-code convention, and A for the enclosure, which the family defines as IP20 and NEMA/UL Type 1.
The class voltage is arithmetic rather than a published claim and it is labelled as such on this page: three-phase rectification gives a bus of roughly 1.35 times the line voltage, so 690 V produces about 931 V and the 932 V DC class is the direct-current counterpart of the 690 V AC class. Read that way, the five DC letters line up with the AC classes rather than forming a separate catalogue.
Precharge is Y in the published voltage table for this class, and that is the single most useful fact for installation. A precharged DC class limits its own inrush when the bus is energised, which is what allows a drive to be connected to a live bus without an external charging arrangement sized for its DC link. The family splits on this elsewhere, with H and J published without precharge and P, R, T and W with it, so the letter is the answer and the frame is not.
The rating code reads as 052, which is 52 amps under the family's convention of three characters with P standing in for the decimal point on fractional values. That reading holds across the AC and DC classes and is independent of the voltage letter, which is why the letter has to be read separately.
Where the published DC block gives horsepower and kW per frame for each of the five DC voltages, this page does not quote a kW for this string. The 932 V column is the only legitimate source for that pairing, and a value taken from the 810 V or 650 V column would be arithmetic presented as data.
An installation at 932 V DC is at the top of the family's voltage range and at the bottom of its current range, and that combination has a specific use: a common bus fed from a 690 V distribution where the sections on it are modest in current. The drive's contribution is its class, its current and its precharge path; the bus, the coordination and the charging sequence remain system decisions.
The DC terminals on the larger frames are published as one group carrying input power, DC+, DC-, BR1, BR2, PE and the motor connections, with wire ranges and torque values given per frame. Even at 52 A the bus joint is the one that runs continuously, so the torque figure is a maintenance item rather than an installation detail.
The brake field follows the family's published rule, Y fitted and N not fitted, standard on frames 0 to 3 and optional on frames 4 to 6. At 52 A the regenerative energy of a section is small compared with the rest of a common bus, so a brake-less string is often the correct choice rather than an omission.
The remaining option characters carry the communication slot, the control type, feedback and documentation, and they are not decoded here. The family's strings vary in length, so a field position is not a safe inference unless the documentation resolves it for that string.
The reason a page like this matters for a search is that most enquiries arrive as a voltage and a power, not as a class letter. Establishing that 932 V DC means the bus of a 690 V installation is the step that turns a customer's description into a catalog string, and getting that step wrong sends the enquiry to the 600 V class.
No lifecycle statement and no price is implied. Class definitions, the precharge entries, the rating-code convention, the enclosure field, the brake rule and the terminal grouping are quoted from the drive family's published documentation; the bus arithmetic is labelled as arithmetic.
The other drives, reactors and drive spares in this range are collected in the Drives & Motors category. Codes documented alongside this one are 20BW098A0ANNANC0, 20BW098A0AYNANC0, 20BW142A0ANNANC0, 20BF119A0ANNANC0, and this drive is listed at 20BW052A0ANNANC0.
The fourth character of a 20B catalog number is the voltage code, and there are twelve of them: five AC classes and seven DC-bus classes. They are not interchangeable, they do not share frame ranges, and the DC codes additionally split on whether a pre-charge circuit is built in. This table is the complete code list from the 20B-TD001 catalog explanation, with the frame range each class is built on.
| Code | Voltage rating | Frames built on | Where the class is used |
| B | 240 V AC, 3-phase, 50/60 Hz | 0-6 | 208...240 V supply, the North American low-voltage class |
| C | 400 V AC, 3-phase, 50/60 Hz | 0-6 | 380...415 V supply, the European standard class |
| D | 480 V AC, 3-phase, 50/60 Hz | 0-6 | 440...480 V supply, the widest rating ladder of the series |
| E | 600 V AC, 3-phase, 50/60 Hz | 0-6 | 575...600 V supply, Canada and heavy industry |
| F | 690 V AC, 3-phase, 50/60 Hz | 5-6 | 690 V supply, and only on the larger frames |
| H | 540 V DC input, pre-charge | 5-6 | fed from a 540 V DC bus, pre-charge circuit built in |
| J | 650 V DC input | 5-6 | 650 V DC common DC bus, no pre-charge letter |
| N | 325 V DC input (Y), pre-charge | 5-6 | 325 V DC bus, common-bus configuration |
| P | 540 V DC input (Y), pre-charge | 5-8 | 540 V DC common bus, the widest DC frame range |
| R | 650 V DC input (Y), pre-charge | 5-8 | 650 V DC common bus, frames 5 through 8 |
| T | 810 V DC input (Y), pre-charge | 5-6 | 810 V DC bus for 600 V class front ends |
| W | 932 V DC input (Y), pre-charge | 5-6 | 932 V DC bus for 690 V class front ends |
Where this page sits: The fourth character of 20BW052A0ANNANC0 is W: 932 V DC input (Y), pre-charge, frames 5-6 in the catalog explanation, with 052 A in the rating field.
What is missing here is the ladder itself: the rating tables that turn these codes into amp, power and frame steps are printed per voltage class in 20B-TD001, and only the 240, 400 and 480 V classes were transcribed for this site. For 600 V, 690 V and the DC-bus classes the neighbouring current steps are therefore not listed, and none is inferred from another class.
Catalog prefix first: 20B is the PowerFlex 700 prefix and 20A is the PowerFlex 70 prefix. A page filed under a "PowerFlex 70 drives" group while carrying a 20B number is a filing error at the prefix level - the two are different product lines with different frame ranges, not variants of one another. The catalog number on the page decides, not the group label.
Source: 20B-TD001 PowerFlex 700 catalog number explanation (voltage, rating and frame codes) and the 20B-TD001 rating tables. Values are quoted as printed; no figure on this page is calculated or extrapolated.