logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 20BP292A0ANNNNC0

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 20BP292A0ANNNNC0

China Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier
Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier Allen Bradley PowerFlex 20BP292A0ANNNNC0 supplier

Large Image :  Allen Bradley PowerFlex 20BP292A0ANNNNC0

Product Details:

Place of Origin: Made in MEXICO
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 20BP292A0ANNNNC0

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $12204.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 2 PCS
Detailed Product Description

20BP292A0ANNNNC0 technical data PDF download 20BP292A0ANNNNC0 PowerFlex 700 292 A, 540 V DC

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PowerFlex 700 drives

20BP292A0ANNNNC0 is a PowerFlex 700 drive, catalog code b=P: 540 V DC input (Y), pre-charge.

The three digits after the voltage letter are the output current in amps - here 292 A. Rockwell does not publish a power rating for this catalog number on its product page, so this page states the current rating only.

Quick answer. 20BP292A0ANNNNC0 is a PowerFlex 700 drive, 540 V DC, normal duty, frame 5-8 range for this voltage class, A - IP 20, NEMA/UL Type 1, with conformal coating.

  • Normal duty output current:
  • Motor rating:
  • Frame: Frame 5-8 range for this voltage class
  • Enclosure: A - IP 20, NEMA/UL Type 1, with conformal coating
  • Communication slot: N - None
  • Control and I/O: C - Vector control, 24 V DC I/O
20BP260A0AYNANC0 260 A, 540 V DC IN STOCK
20BP260A0ANNANC0 260 A, 540 V DC IN STOCK
20BP205A3ANNANC0 205 A, 540 V DC IN STOCK
20BP205A0ANNANC0 205 A, 540 V DC IN STOCK
20BP170A0AYNANC0 170 A, 540 V DC IN STOCK
20BP170A0ANNANC1 170 A, 540 V DC IN STOCK
20BP170A0ANNANC0 170 A, 540 V DC IN STOCK
20BP140A3ANNANC0 140 A, 540 V DC IN STOCK
20BP730N0NNNNNC0 730 A, 540 V DC IN STOCK
20BP535U0ANNNNC0 535 A, 540 V DC IN STOCK
20BP535N0NNNNNC0 535 A, 540 V DC IN STOCK
20BP481N0NNNNNC0 481 A, 540 V DC IN STOCK
20BP365A0ANNNNC0 365 A, 540 V DC IN STOCK
20BP325A0ANNNNC0 325 A, 540 V DC IN STOCK
20BP292N0NNNNNC0 292 A, 540 V DC IN STOCK
20BP292A0ANNNNC0 292 A, 540 V DC IN STOCK
20BP260A3ANNANC0 260 A, 540 V DC IN STOCK
20BP205A0AYNANC0 205 A, 540 V DC IN STOCK
20BP140A0AYNANC0 140 A, 540 V DC IN STOCK
20BP140A0ANNANC0 140 A, 540 V DC IN STOCK
20BP125A0AYNANC0 125 A, 540 V DC IN STOCK
20BP105A0AYNANC0 105 A, 540 V DC IN STOCK
20BP105A0ANNANC1 105 A, 540 V DC IN STOCK
20BP105A0ANNANC0 105 A, 540 V DC IN STOCK

Product Specifications 20BP292A0ANNNNC0 (PDF)
 Catalog number
 20BP292A0ANNNNC0
 Voltage rating (b)
 P - 540 V DC input (Y), pre-charge
 Output current rating (c)
 292 A
 Frame size
 Frame 5-8 range for this voltage class
 Enclosure (d)
 A - IP 20, NEMA/UL Type 1, with conformal coating
 HIM (e)
 0 - Blank cover
 Documentation (f)
 A - Manual included
 Brake IGBT (g)
 N - No brake IGBT
 Internal braking resistor (h)
 N - No internal braking resistor
 Emission class (i)
 N - No CE filter, no CM choke
 Comm slot (j)
 N - None
 Control and I/O (k)
 C - Vector control, 24 V DC I/O
 Feedback (l)
 0 - No feedback
 Rating code
 292 - read as the output current in amps
 Source
 20B-TD001 p.6-7 catalog explanation; rating and frame from the Rockwell product page

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 20B-TD001 (Sept 2023) (module specifications) and 20B-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

20BP292A0ANNNNC0 20BP292A0ANNNNC0 20BP292A0ANNNNC0 20BP292A0ANNNNC0 20BP292A0ANNNNC0 20BP292A0ANNNNC0 20BP292A0ANNNNC0

How to read this catalog number

The string is 20B (drive), P (voltage), 292 (output current in amps), then nine option positions d to l.

Here: d=A, e=0, f=A, g=N, h=N, i=N, j=N, k=C, l=0.

Two more positions m and n exist for future use and special firmware; they are omitted on most orders.

What each position controls

Enclosure (d): IP 20, NEMA/UL Type 1, with conformal coating.

HIM (e): Blank cover. Remote HIM codes J and K mount on a panel door and need the stand-alone IP 54 enclosure.

Brake IGBT (g): No brake IGBT. Internal braking resistor (h): No internal braking resistor; Rockwell does not offer the internal resistor on frame 3 and larger.

Emission (i): No CE filter fitted. Comm slot (j): None. Control and I/O (k): Vector control, 24 V DC I/O. Feedback (l): No feedback.

DC input instead of an AC front end

A 540 V DC input PowerFlex 700 takes its power from a common DC bus instead of a three-phase rectifier.

Pre-charge is in the catalog code (the Y in position b), so the drive expects the DC bus to be brought up by the line-side pre-charge circuit rather than by the drive itself.

This is the difference an engineer checks first: a 20BP is not a drop-in replacement for a 20BD fed from 480 V AC.

What to verify before buying used

Nameplate catalog number, all 16 characters, against this page.

Whether the frame 5 or 6 enclosure is present; open/flange (d=F) and stand-alone (d=G) drives are the same chassis in different packaging.

Encoder board presence (l=1) and the brake IGBT (g=Y), because both are separate hardware, not parameters.

Documented source

For 20BP292A0ANNNNC0 the positions, voltage classes and option codes are transcribed from 20B-TD001 (September 2023), Catalog Number Explanation, pages 6 and 7, and cross-checked against 20B-UM001 page P-5.

Current, power and frame figures for 20BP292A0ANNNNC0 are taken from the product page for this catalog number; where that page carries no power rating, none is shown here.

FAQ — 20BP292A0ANNNNC0

What is 20BP292A0ANNNNC0?

PowerFlex 700 drive, 540 V DC input (Y), pre-charge, 292 A output.

What is the output current of 20BP292A0ANNNNC0?

292 A.

What does the P code mean?

540 V DC input (Y), pre-charge.

Does 20BP292A0ANNNNC0 have a communication option?

None.

What enclosure is 20BP292A0ANNNNC0?

IP 20, NEMA/UL Type 1, with conformal coating.

Related catalog numbers in the same rating code as 20BP292A0ANNNNC0. Same A power stage, different option string - the enclosure, HIM, communication and safety positions are what change between them.

20BP260A0AYNANC0 (260 A, 540 V DC) · 20BP260A0ANNANC0 (260 A, 540 V DC) · 20BP205A3ANNANC0 (205 A, 540 V DC) · 20BP205A0ANNANC0 (205 A, 540 V DC) · 20BP170A0AYNANC0 (170 A, 540 V DC) · 20BP170A0ANNANC1 (170 A, 540 V DC) · 20BP170A0ANNANC0 (170 A, 540 V DC) · 20BP140A3ANNANC0 (140 A, 540 V DC) · 20BP730N0NNNNNC0 (730 A, 540 V DC) · 20BP535U0ANNNNC0 (535 A, 540 V DC)


Data sources. For 20BP292A0ANNNNC0, decoded from Rockwell 20B-TD001 p.6-7 Catalog Number Explanation; rating and frame from the product page for this catalog number. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

20BP292A0ANNNNC0

This page documents catalog number 20BP292A0ANNNNC0, a PowerFlex 700 DC input drive built on frame 7 with the 540 V DC precharge arrangement, as published by Rockwell Automation in 20B-IN014 and 20B-TD001. Every value below comes from those publications; nothing is inferred.

Rating for this catalog number

SpecificationValue
Output current, normal duty292 A
Normal duty rating160 kW at 4 kHz, 40 °C
Heavy duty rating150 kW, 263 A continuous
DC input rating342 A, 185 kW at 160 kW output
Output current, 1 min322 A
Output current, 3 s438 A
Semiconductor fuse500 A, catalog number 170M6608
Frame7
Input voltage rating540 V DC, with internal precharge
Voltage code in catalog numberP = 540 V DC
InputDC bus, no AC rectifier stage, DC+ and DC- terminals
Output phases3
Precharge interlockAuxiliary contact on the disconnector to a digital input, parameter 361...366 set to option 30 precharge enable, and to TB1 on the precharge board
Precharge board jumpersJMP1: 1-2 = 24 V DC input, 2-3 = 120 V AC input. JMP2: 1-2 = interlock, 2-3 = bypass (default). JMP3: 1-2 = do not use, 2-3 = bypass
Disconnector ruleNot to be used between the drive input and a common DC bus without an external precharge device
Control voltage codeC = vector control with 24 V DC I/O
LifecycleBulletin announced discontinued 2023-11-30, replacement category Engineering Replacement

What the option string says

The catalog number is a readable specification once each position is decoded against the bulletin catalog explanation. For this unit the positions read as follows:

SpecificationValue
Position in catalog numberPublished meaning
Enclosure code AIP20, NEMA/UL Type 1, with conformal coating
HIM code 0blank cover, no keypad
Documentation code Amanual supplied
Brake code Nno brake IGBT
Resistor code Nno drive mounted brake resistor
Emission code Nno internal CE filter
Communication code Nno communication module
Control code Cvector control with 24 V DC I/O
Feedback code 0no encoder feedback

Consequences on site

Frames 7 through 9 carry an internal precharge board, and frame 10 does not; the instructions treat the two cases separately. Where the board is present, the interlock contact goes to TB1 and the drive is expected to see the disconnector state on a digital input. Where the board is absent, precharge capability has to be provided by the system, which means an external charging path and its own interlock. Mixing the two procedures is how a drive gets energised through a path nobody verified.

Frames 7 through 9 carry an internal precharge board, and frame 10 does not; the instructions treat the two cases separately. Where the board is present, the interlock contact goes to TB1 and the drive is expected to see the disconnector state on a digital input. Where the board is absent, precharge capability has to be provided by the system, which means an external charging path and its own interlock. Mixing the two procedures is how a drive gets energised through a path nobody verified.

Every row of this table is a site decision, not a catalog curiosity. The fuse catalog number has to be bought as a semiconductor fuse of that family, the switching frequency and ambient go together, and the precharge interlock is a wiring item that has to exist before the disconnector is closed. A drive that arrives with factory jumper positions and factory defaults is a drive that has not yet been configured for the panel it was bought for.

Scope of the published data

Only values that appear in 20B-IN014 or 20B-TD001 are printed here. The heavy duty row, the DC input current, the fuse catalog number and the one minute and three second output columns are taken from the frames 7...10 installation instructions rather than transferred from another frame or another voltage class. Where a figure is not published for this catalog number the table says so instead of carrying a substitute; enclosure position letters are quoted as printed in the catalog number, and the IP class for these frames is stated in the frames 7...10 instructions rather than in the seed catalog explanation.

The precharge board on frames 7 through 9 carries three jumper blocks. JMP1 selects the auxiliary control supply, 24 V DC on positions 1-2 and 120 V AC on positions 2-3. JMP2 selects interlock or bypass on the precharge contactor path, with bypass as the factory default. JMP3 must be left on positions 1-2 and is marked do not use; the bypass setting on 2-3 exists for test benches. Reading those three blocks before closing a disconnector is cheaper than replacing a precharge resistor.

DC input current is not the same as output current, and on a common-bus drive the difference is the point. The input row states the current the drive draws from the bus at its rated output, while the output row states what it delivers to the motor, including the one minute and three second overload columns. A panel that sizes its DC bus bars from the output rating alone will run the bus at a higher current than the drawing shows during acceleration.

Where a site runs several inverters from one rectifier, the DC bus bars, the discharge path and the precharge interlock are the three drawings that maintenance actually needs. The drive's own catalog number says nothing about the other two, but it does say what the drive expects: a precharge enable signal on a digital input, a contact on TB1, and an auxiliary contact on the disconnector. Those expectations are the interface to the rest of the bus.

The DC bus is a hazard that outlives the command to stop. Capacitors hold charge after the disconnector opens, and on a shared bus they can be held up by another drive still running. Instructions that require a proven discharge path and an interlock are not paperwork: they are the difference between a maintenance window and an incident. Publishing the interlock requirement on the product page puts it in front of the person who specifies the panel, not only the person who reads the manual afterwards.

The fuse figures in this range are semiconductor fuses with published catalog numbers, not generic ampere ratings. That matters because the fuse has to protect the module before the module's own overcurrent trip acts, and a substitute of the same amp rating from a different family does not carry the same clearing characteristic. The instructions list the fuse by catalog number alongside the DC input current, which is the only honest way to specify it for a retrofit.

Common-bus arrangements pay off where several motors work against each other: one axis regenerating while another accelerates, with the energy circulating on the bus instead of being dissipated. The cost is that the bus becomes a single point of failure with several owners. A drive page that publishes the DC input current, the fuse catalog number and the precharge interlock requirement gives the panel designer the three facts needed to make that shared asset safe rather than merely functional.

A spare for a frame 7 through 10 unit is a capital item, and the decision to hold one is usually taken after the first unplanned stop. The information needed to place that order years later is the full catalog string, the fuse catalog number and the jumper settings as found on site. Two of those three live in the installation instructions, which is why a page that quotes them from the publication is worth more than one that repeats a sales description.

Where the drive is fed through a disconnector from a common DC bus, the instructions are explicit: an auxiliary contact on the disconnector must be wired to a digital input, and the corresponding parameter between 361 and 366 must be set to option 30, precharge enable. The same auxiliary contact also goes to TB1 on the precharge board so the board knows the disconnector state. Skipping either half leaves the drive able to close onto an uncharged bus, which is the failure the interlock exists to prevent.

A drive this size is usually ordered as a spare against an existing line rather than as new equipment, and the suffix letters decide whether the spare can be dropped in. A unit with the manual and the filtered build is not the same physical object as one supplied without a manual and without the filter, even though the power code, the frame and the DC input current are identical. Recording only the amp code is how a spare arrives that fits the mounting but not the panel drawing.

Terminal capacity and torque on the larger frames are stated per frame rather than per amp code, because the power structure is the same across several ratings. Tightening a DC terminal to a torque taken from a smaller frame is a common field error: the terminal accepts the conductor, the joint is under-torqued, and the failure appears months later as a hot spot rather than as an immediate fault.

Frames 7 through 10 are the part of this range where the installation instructions, not the catalog explanation, become the working document. At these ratings the drive is a cabinet-mounted power structure with a precharge board, a TB1 terminal strip and jumper blocks that have to be set for the site's control voltage before the first energisation. A drive ordered from a suffix string arrives with the factory default jumper positions, and the default is not always the one the panel was designed around.

Switching frequency on the larger frames is 2 kHz, and 4 kHz on frame 7. That figure is not a preference: it is the value the published ratings were established at, together with the ambient temperature printed in the same row. Choosing a higher switching frequency to reduce audible noise moves the drive outside the derating table, and the amp code that looked adequate on paper then has to be re-checked against the derating curves before the order is placed.

The published ambient for these rows is 40 degrees C, and it is printed in the same table as the switching frequency because the two together define the rating. A cabinet that reaches 45 degrees C in summer is outside the row the drive was selected from, and the answer is not a bigger drive but either more airflow or a lower switching frequency. Neither adjustment is obvious from a nameplate, which is why both figures belong on the page rather than in an appendix.

Catalog numbers, options and spare parts for the same PowerFlex 700 range are listed in the Drives & Motors category. This drive itself can be checked against the shop listing at 20BP292A0ANNNNC0.

Other catalog numbers and accessories for the same range are collected in the Allen-Bradley PowerFlex drives and motors category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)