logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 20BF098A0ANNANC0

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 20BF098A0ANNANC0

China Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier
Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier Allen Bradley PowerFlex 20BF098A0ANNANC0 supplier

Large Image :  Allen Bradley PowerFlex 20BF098A0ANNANC0

Product Details:

Place of Origin: Made in MEXICO
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 20BF098A0ANNANC0

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $8648.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 2 PCS
Detailed Product Description

20BF098A0ANNANC0

This page documents catalog number 20BF098A0ANNANC0, a PowerFlex 700 drive in the 690 V AC class at 98 A on frame 6. The decode and ratings come from the drive family's published catalog number explanation and 690 V normal-duty table; the trailing option block is not interpreted beyond the enclosure field.

Decode and published ratings

SpecificationValue
Catalog number20BF098A0ANNANC0
Family (first three characters)20B - PowerFlex 700
Voltage class (fourth character)F - 690 V AC, three-phase, frames 5-6 only
Rating code (fifth to seventh)098 - 98 A
Enclosure field (fourth block)A - IP20, NEMA/UL Type 1
Normal-duty rating, 690 V 50 Hz table98 A, 90 kW
Frame as published6
Horsepower equivalentapproximately 125 Hp (arithmetic from kW, not a published Hp pairing for this class)
Full power range, 690 V class690...759 V
Operating range, 690 V class475...759 V
Nominal motor voltage690 V
Line reactor pairing for 690 VNot printed in the reactor tables retrieved (those cover 240 V, 480 V and 600 V)
Brake IGBT availabilityStandard on frames 0-3, optional on frames 4-6

What the class decides and what the nameplate still has to say

This number is the 98 A code of the 690 V PowerFlex 700 range and the first one in the class that sits on frame 6. Reading it: 20B is the family, F is 690 V AC three-phase, 098 is the output current, A is the enclosure field which the family defines as IP20 and NEMA/UL Type 1.

The published normal-duty row for this code is 98 A at 90 kW on frame 6 in the 690 V, 50 Hz table. The kilowatt figure is the manual's; the horsepower equivalent of about 125 is arithmetic from it and is not a published Hp pairing for this voltage class, so a quotation that states horsepower should be checked against the voltage class it is quoting.

Frame 6 is the top of the range on this platform, and that has three consequences that matter more than the rating itself. The mounting footprint and the cabinet volume are those of the largest frame; the ambient rating published for frames 5 and 6 differs from the frames 0 to 4 figures; and the spare parts set is the frame's rather than the rating's.

The voltage envelope for the 690 V class on frames 5 and 6 is a nominal motor voltage of 690 V, a full power range of 690 to 759 V and an operating range of 475 to 759 V. At 98 A the derating band at the bottom of that window is wide enough that a plant with a weak supply should measure the voltage at the drive terminals before accepting the rating in a tender.

The reactor pairing is not printed for 690 V in the reactor tables retrieved for this page, which cover 240 V, 480 V and 600 V. On a frame 6 drive the physical size of an input reactor is itself a panel design item, so the absence of a published pairing is a reason to obtain the current documentation rather than to fit a part sized by analogy.

Two listings in this shop carry this family, voltage and rating code and differ in the trailing block, which is the normal consequence of an option field rather than of two ratings. The page you are reading is the entry whose string ends NANC0; the other entry is listed separately and is not merged here, because the option fields are exactly what a buyer has to match.

The option region carries brake IGBT, communication slot, control type, feedback and documentation. The brake field is the one with an installation consequence: the family notes the brake IGBT is standard on frames 0 to 3 and optional on frames 4 to 6, and frame 6 is firmly inside the optional range, so a drive without it cannot dissipate regenerative energy into a resistor.

Enclosure A as IP20 and NEMA/UL Type 1 means cabinet protection, and on a frame 6 drive the cabinet's thermal design is the dominant engineering question. The drive's own published ambient figure is measured at the drive, and the difference between that and the room temperature is the cabinet's job.

What this page does not do is decode the trailing letters into a brake or a network. The position of those fields shifts with the length of the string in this family, and a page that pinned them from one example would be making a claim about a live panel's wiring from a pattern.

The practical use of this page is the current figure and the frame. A 98 A drive on frame 6 is a component that has to be planned into a panel at layout time, and the check that matters before ordering is the motor's full-load current at the actual 690 V supply rather than the motor's nameplate current at a nominal the plant may not deliver.

The kilowatt figure of 90 is the published one for this code, and the 125 horsepower equivalent is arithmetic. In a European tender the kilowatt figure is the bid item, and in a North American retrofit the horsepower figure is the conversation, which is exactly the situation where a unit gets lost between two documents.

A drive at this rating is normally selected against a motor's full-load current with a margin, and the margin is what the operating range tests. At 98 A and a nominal 690 V, a supply sitting at 520 V leaves the drive running but with far less torque authority, so a load that needs breakaway torque will show the shortfall at the first cold start rather than at commissioning.

The other drives, reactors and drive spares in this range are collected in the Drives & Motors category. Neighbouring entries and ratings are listed at 20BF060A0AYNANC0, 20BF082A0ANNANC0, 20BF098A0AYNANC0, and this drive is listed at 20BF098A0ANNANC0.

The twelve 20B voltage codes, and the frames each one is built on

The fourth character of a 20B catalog number is the voltage code, and there are twelve of them: five AC classes and seven DC-bus classes. They are not interchangeable, they do not share frame ranges, and the DC codes additionally split on whether a pre-charge circuit is built in. This table is the complete code list from the 20B-TD001 catalog explanation, with the frame range each class is built on.

CodeVoltage ratingFrames built onWhere the class is used
B240 V AC, 3-phase, 50/60 Hz0-6208...240 V supply, the North American low-voltage class
C400 V AC, 3-phase, 50/60 Hz0-6380...415 V supply, the European standard class
D480 V AC, 3-phase, 50/60 Hz0-6440...480 V supply, the widest rating ladder of the series
E600 V AC, 3-phase, 50/60 Hz0-6575...600 V supply, Canada and heavy industry
F690 V AC, 3-phase, 50/60 Hz5-6690 V supply, and only on the larger frames
H540 V DC input, pre-charge5-6fed from a 540 V DC bus, pre-charge circuit built in
J650 V DC input5-6650 V DC common DC bus, no pre-charge letter
N325 V DC input (Y), pre-charge5-6325 V DC bus, common-bus configuration
P540 V DC input (Y), pre-charge5-8540 V DC common bus, the widest DC frame range
R650 V DC input (Y), pre-charge5-8650 V DC common bus, frames 5 through 8
T810 V DC input (Y), pre-charge5-6810 V DC bus for 600 V class front ends
W932 V DC input (Y), pre-charge5-6932 V DC bus for 690 V class front ends

Where this page sits: The fourth character of 20BF098A0ANNANC0 is F: 690 V AC, 3-phase, 50/60 Hz, frames 5-6 in the catalog explanation, with 098 A in the rating field.

What is missing here is the ladder itself: the rating tables that turn these codes into amp, power and frame steps are printed per voltage class in 20B-TD001, and only the 240, 400 and 480 V classes were transcribed for this site. For 600 V, 690 V and the DC-bus classes the neighbouring current steps are therefore not listed, and none is inferred from another class.

Catalog prefix first: 20B is the PowerFlex 700 prefix and 20A is the PowerFlex 70 prefix. A page filed under a "PowerFlex 70 drives" group while carrying a 20B number is a filing error at the prefix level - the two are different product lines with different frame ranges, not variants of one another. The catalog number on the page decides, not the group label.

Source: 20B-TD001 PowerFlex 700 catalog number explanation (voltage, rating and frame codes) and the 20B-TD001 rating tables. Values are quoted as printed; no figure on this page is calculated or extrapolated.