Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 20BE6P1A0AYNAND0, a PowerFlex 700 drive in the 600 V AC class at 6.1 A. The decode and the ratings below are taken from the drive family's published catalog number explanation and line reactor tables; the trailing option blocks are not interpreted here.
| Specification | Value |
|---|---|
| Catalog number | 20BE6P1A0AYNAND0 |
| Family (first three characters) | 20B - PowerFlex 700 |
| Voltage class (fourth character) | E - 600 V AC, three-phase |
| Rating code (fifth to seventh) | 6P1 - 6.1 A |
| Heavy-duty rating as published | No heavy-duty pairing printed for this code |
| Normal-duty rating as published | 5 Hp |
| Input line reactor, heavy duty | n/a |
| Output line reactor, heavy duty | n/a |
| Input line reactor, normal duty | 1321-3R8-C |
| Output line reactor, normal duty | 1321-3RA8-C |
| Full power range, 600 V class frames 0-4 | 575...660 V |
| Operating range, 600 V class frames 0-4 | 432...660 V |
| Nominal motor voltage | 575 V |
| Low voltage directive note | 600 V class below 77 A (frames 0-4) declared to meet the Low Voltage Directive; EMC compliance determined by the user |
This number is the 6.1 A step of the 600 V PowerFlex 700 range, and it is the point where the published reactor table stops listing a heavy-duty pairing and starts listing normal duty only. Reading the string: 20B is the family, E is 600 V AC three-phase, 6P1 is 6.1 A.
For this code the line reactor table gives a normal-duty rating of 5 Hp with a 1321-3R8-C input reactor and a 1321-3RA8-C output reactor, and no heavy-duty entry. That absence is a real piece of information rather than a gap in the table: at this rating the family's published pairing is the normal-duty one, and a buyer who needs a heavy-duty 5 Hp 600 V drive is looking at a different code rather than at a different column.
The duty question is still live, because PowerFlex 700 drives carry heavy-duty and normal-duty ratings on the same hardware and select between them in programming. What the table fixes is the reactor pairing published for this code, and that pairing is what a panel needs when the drive is being installed rather than merely replaced.
The 600 V class voltage envelope on frames 0 to 4 is 575 to 660 V for full power and 432 to 660 V for operation against a 575 V nominal motor. Below 575 V the drive derates linearly. At 6.1 A the practical reading is that a motor rated for 575 V and drawing close to 6 A at nominal voltage has no headroom at the bottom of the band.
The compliance line for this class: 600 V drives below 77 A on frames 0 to 4 are declared to meet the Low Voltage Directive, with EMC compliance determined by the user. The 6.1 A rating is well inside that band.
Frame group follows from the reactor number as it does across the range. A drive taking 3R8 on the input sits above the 3R4 group and below the 3R12 group, which is the quickest identification available when the label is unreadable and the panel is already open.
The trailing blocks of the number are not read as enclosure, brake or communication codes here. Those fields have their own tables, and a page that decoded them from pattern would be making a claim about wiring that this page cannot support.
The checks that belong with a 6.1 A drive are the ones that keep a small motor alive: actual line voltage against the derating curve, motor full-load current against 6.1 A, and the overload class set in the drive against the motor's thermal time. Small drives fail from mis-set overload far more often than from undersized current.
Adjacent ratings are 3P9 at 3.9 A and 9P0 at 9.0 A, each with its own reactor pair. The step from 6P1 to 9P0 crosses into the group where the input reactor number changes again, so the substitution is a frame decision.
A code with a published normal-duty pairing and no heavy-duty entry is not a weaker drive; it is a drive whose published reactor pairing has been standardised on one duty. That matters at quotation time, because a request for a heavy-duty 5 Hp 600 V drive is answered by a different rating code and a different frame rather than by adding an option to this one.
Five horsepower on a 600 V three-phase supply is the size that shows up on cooling tower fans, small process pumps and dust collection. Those loads shed torque quickly as speed falls, which is why the normal-duty figure is the one the published table carries for this code, and why a variable-torque application is the natural fit rather than a marginal one.
The reactor pair for this code is 3R8 on both sides, the only pair in this sampled range where input and output numbers match. That symmetry is a convenient identification handle: a drive in the panel with matched reactors on both sides is in this group, and a drive with mismatched reactors is above or below it.
The derating curve is what makes a 6.1 A rating honest in the field. A motor that draws 5.8 A at 575 V draws more at 550 V, and the drive's linear derating below the full power floor is the mechanism that keeps the output current inside the silicon's limit. The check is the motor current at the measured line voltage, not at the plant's nominal figure.
The rest of the drives, reactors and drive spares in this range are collected in the Drives & Motors category. Numbers one step either side of this rating are listed at 20BE017A0AYNAND0, 20BE027A0AYNAND0, 20BE2P7A0AYNAND0, and the drive this page describes is listed at 20BE6P1A0AYNAND0.
20BE6P1A0AYNAND0 is one of two 600 V class PowerFlex 700 codes on this site and the larger of the pair. The two tables below set the rating rows and the reactor rows side by side: this code prints one duty rating where its sibling prints two.
| Catalog number | Rating code | Continuous current | Heavy-duty rating | Normal-duty rating |
|---|---|---|---|---|
| 20BE2P7A0AYNAND0 | 2P7 | 2.7 A | 1 Hp | 2 Hp |
| 20BE6P1A0AYNAND0 | 6P1 | 6.1 A | no heavy-duty pairing printed | 5 Hp |
| Catalog number | Input reactor, heavy duty | Output reactor, heavy duty | Input reactor, normal duty | Output reactor, normal duty |
|---|---|---|---|---|
| 20BE2P7A0AYNAND0 | 1321-3R2-B | 1321-3RA2-B | 1321-3R4-D | 1321-3RA4-D |
| 20BE6P1A0AYNAND0 | n/a | n/a | 1321-3R8-C | 1321-3RA8-C |
Both records print the same three voltage statements and no derating curve between them: a full power range of 575 to 660 V, an operating range of 432 to 660 V, and a nominal motor voltage of 575 V. Read together that says the drive will accept a bus down to 432 V, which is three quarters of nominal, while claiming full power only from 575 V upward, and the record does not print what the drive delivers in the 143 V band between the two. A plant on a weak 600 V supply is therefore inside the operating window and outside the full power window at the same time.
6.1 A prints no heavy-duty pairing at all: the heavy-duty rating row says there is none for this code and both heavy-duty reactor rows say n/a, while normal duty is 5 Hp with 1321-3R8-C and 1321-3RA8-C. So this record is single-rated, and a machine sized on heavy duty cannot be quoted from it - it needs a different code, not a different reactor.
What neither 600 V record settles: the frame letter of each code, the output current derating between 432 and 575 V, an EMC filter part number despite the EMC statement being handed to the user, an enclosure rating, a weight or dimension, a heat figure in watts, and any lifecycle field. The reactor numbers are printed; the reactors themselves are not priced or specified here.
Source: the published rows of 20BE2P7A0AYNAND0 and 20BE6P1A0AYNAND0 - the catalog number decode, heavy and normal duty ratings, the four reactor part numbers per code, the full power and operating voltage ranges, the nominal motor voltage and the Low Voltage Directive statement. The ampere per horsepower comparison is arithmetic on those printed figures; the derating band is the gap between the two printed voltage ranges, and no curve for it is printed.
Sources. Rockwell publishes the technical data for the PowerFlex 700 range as 20B-TD001, and the installation instructions split by frame size, with 20B-IN019 covering frames 0…6 and 20B-IN014 covering frames 7…10. The ratings, current figures and ordering characters quoted on this page for 20BE6P1A0AYNAND0 follow those publications, and the user manual for the frames covered here is 20B-UM001.