Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 20BE062A0AYNAND0, a PowerFlex 700 drive in the 600 V AC class at 62 A. The decode and ratings come from the drive family's published catalog number explanation and line reactor tables; the trailing option block is not interpreted beyond the enclosure field.
| Specification | Value |
|---|---|
| Catalog number | 20BE062A0AYNAND0 |
| Family (first three characters) | 20B - PowerFlex 700 |
| Voltage class (fourth character) | E - 600 V AC, three-phase |
| Rating code (fifth to seventh) | 062 - 62 A |
| Enclosure field (fourth block) | A - IP20, NEMA/UL Type 1 |
| Heavy-duty rating as published | 50 Hp |
| Normal-duty rating as published | 60 Hp |
| Input line reactor, heavy duty | 1321-3R55-B |
| Output line reactor, heavy duty | 1321-3R80-B |
| Input line reactor, normal duty | 1321-3R80-B |
| Output line reactor, normal duty | 1321-3R80-B |
| Full power range, 600 V class frames 0-4 | 575...660 V |
| Operating range, 600 V class frames 0-4 | 432...660 V |
| Nominal motor voltage | 575 V |
| Brake IGBT availability | Standard on frames 0-3, optional on frames 4-6 |
| Low voltage directive note | 600 V class below 77 A (frames 0-4) declared to meet the Low Voltage Directive; EMC compliance determined by the user |
This number is the 62 A step of the 600 V PowerFlex 700 range, and it sits close enough to the 77 A line that the compliance sentence for the class becomes the first thing a machine builder checks rather than the last. The string reads 20B for the family, E for 600 V AC three-phase, 062 for the output current, and A in the enclosure field, which the family defines as IP20, NEMA/UL Type 1.
The published pairing is a heavy-duty rating of 50 Hp with a 1321-3R55-B input reactor and a 1321-3R80-B output reactor, and a normal-duty rating of 60 Hp with the 3R80-B part on both sides. The jump from 55 to 80 on the output side is the largest ratio in the sampled part of this table, and it reflects how much motor-side current has to be absorbed at this rating under constant-torque duty.
Heavy duty at 50 Hp and normal duty at 60 Hp describe the same hardware under two duty assumptions, selected in programming rather than at purchase. The practical consequence is that a quotation naming only the catalog number has not answered the question the buyer is actually asking, which is how many horsepower the drive will hold without tripping.
The voltage window for the class on frames 0 to 4 is 575 to 660 V for full power and 432 to 660 V for operation, with 575 V as the nominal motor voltage and linear derating below the full power floor. At 62 A the derating band matters more than it does on smaller codes, because a motor drawing close to the rating at nominal voltage has no headroom at 550 V.
The compliance sentence is the one that decides a file rather than a panel: 600 V class drives below 77 A on frames 0 to 4 are declared to meet the Low Voltage Directive, and EMC compliance is left to the user. This code is inside that band with a margin of 15 A, and the next code up, 077, is at the edge of it, which is why the two are not interchangeable in a declaration even though they are neighbours in a catalog.
Enclosure A is read here with confidence because the family's enclosure table defines it as IP20 and NEMA/UL Type 1. In an IP20 enclosure the drive depends on the cabinet for contamination protection, so the statement belongs to the enclosure design rather than to the drive's own ingress rating.
The brake option is worth naming at this size for a structural reason rather than a sales one: the family's catalog explanation notes that the brake IGBT is standard on frames 0 to 3 and optional on frames 4 to 6. A 60 Hp 600 V drive sits in the upper part of that range, so the brake is a field that has to be read rather than assumed, and two strings that differ only at the end can differ exactly there.
The rest of the trailing block is not interpreted on this page. Communication slot, control type, feedback and documentation each have their own table, and this page does not restate them because a wrong guess about a comm slot is a wrong guess about a network card in a live panel.
Identification in the field follows the reactor, as it does across the range. A drive with 3R55 on the input is running this code's heavy-duty pairing; 3R80 in both positions is the normal-duty pairing. The reactors are mounted where they can be read, which is more than can be said for the nameplate behind the door.
Adjacent ratings are 052 at 52 A and 077 at 77 A, and the 077 code is where the class's low-voltage declaration boundary falls. A substitution from 062 to 077 changes both the reactor pair and the compliance margin, so it is not a like-for-like replacement in a machine file.
No lifecycle statement and no price is implied. The ratings, reactor numbers, voltage window, enclosure definition and brake-availability rule are quoted from the drive family's published tables, and the compliance sentence is quoted rather than paraphrased.
The reason the 80 A reactor appears on this code and not on the one below it is worth one sentence, because it is the kind of detail that decides whether a panel has room for the part. Motor-side current at this rating carries harmonic content that the input side does not, and the output reactor is sized for that content rather than for the motor's nameplate current. Fitting a reactor sized for the input side in the output position is a common and invisible error.
A spare ordered against this code should be ordered with the duty stated on the purchase order. The two duty pairings differ in the output reactor, which means two nominally identical drives can arrive with different hardware fitted, and the difference only surfaces when the resistor or reactor is being connected.
Sixty horsepower at 600 V is a size that usually runs a pump or a fan in a process section, and it is also the size where a buy-back of a failed drive most often ends in a like-for-like replacement rather than an upgrade. That makes the nameplate record the important document: the option fields on this drive are what a replacement has to match, not the enclosure dimensions.
The other drives, reactors and drive spares in this range are collected in the Drives & Motors category. The neighbouring ratings and entries are listed at 20BE052A0AYNANA0, 20BE062A0ANNAND0, and this drive is listed at 20BE062A0AYNAND0.
Sources. Rockwell publishes the technical data for the PowerFlex 700 range as 20B-TD001, and the installation instructions split by frame size, with 20B-IN019 covering frames 0…6 and 20B-IN014 covering frames 7…10. The ratings, current figures and ordering characters quoted on this page for 20BE062A0AYNAND0 follow those publications, and the user manual for the frames covered here is 20B-UM001.