Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier Allen Bradley PowerFlex 20BE062A0ANNAND0 supplier

Large Image :  Allen Bradley PowerFlex 20BE062A0ANNAND0

Product Details:

Place of Origin: Made in MEXICO
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 20BE062A0ANNAND0

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $6283.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 2 PCS
Detailed Product Description

20BE062A0ANNAND0

This page documents catalog number 20BE062A0ANNAND0, a PowerFlex 700 drive in the 600 V AC class at 62 A. The decode and ratings come from the drive family's published catalog number explanation and line reactor tables; the trailing option block is not interpreted beyond the enclosure field.

Decode and published ratings

SpecificationValue
Catalog number20BE062A0ANNAND0
Family (first three characters)20B - PowerFlex 700
Voltage class (fourth character)E - 600 V AC, three-phase
Rating code (fifth to seventh)062 - 62 A
Enclosure field (fourth block)A - IP20, NEMA/UL Type 1
Heavy-duty rating as published50 Hp
Normal-duty rating as published60 Hp
Input line reactor, heavy duty1321-3R55-B
Output line reactor, heavy duty1321-3R80-B
Input line reactor, normal duty1321-3R80-B
Output line reactor, normal duty1321-3R80-B
Full power range, 600 V class frames 0-4575...660 V
Operating range, 600 V class frames 0-4432...660 V
Nominal motor voltage575 V
Brake IGBT availabilityStandard on frames 0-3, optional on frames 4-6
Low voltage directive note600 V class below 77 A (frames 0-4) declared to meet the Low Voltage Directive; EMC compliance determined by the user

What the number fixes and what it leaves to the nameplate

This catalog string carries the same family, voltage class and rating code as the neighbouring 20BE062 entry in this shop, and the difference between the two sits entirely in the trailing option block. Reading what is certain first: 20B is PowerFlex 700, E is 600 V AC three-phase, 062 is 62 A, and the fourth field A is the enclosure, which the family defines as IP20 and NEMA/UL Type 1.

The ratings are therefore identical to the other 062 entry: heavy duty at 50 Hp with a 1321-3R55-B input reactor and a 1321-3R80-B output reactor, normal duty at 60 Hp with the 3R80-B part on both sides, a full power window of 575 to 660 V and an operating window of 432 to 660 V, and the class compliance sentence for drives below 77 A on frames 0 to 4.

What differs is one character in the option region, and the honest way to handle that is to name the fields that live there rather than to declare which one changed. The family's catalog explanation places brake IGBT, communication slot, control type, feedback and documentation in that region, and it gives each of them a separate table. A page that announced a specific option from a single character would be making a wiring claim from a pattern.

One field in that region is worth explaining because it is the one most likely to be the difference and the one with a real installation consequence: the brake IGBT. The family notes that it is standard on frames 0 to 3 and optional on frames 4 to 6. A 60 Hp 600 V drive sits high enough in the frame range that the brake is genuinely optional, so two otherwise identical 62 A drives can differ in whether a braking resistor can be wired directly to the drive's terminals.

That consequence is not cosmetic. Without the brake IGBT a drive cannot dissipate regenerative energy into a resistor, so a load that overhauls the motor, or a machine that has to stop a high-inertia axis quickly, needs either the brake option or an external braking unit. The catalog number is where that decision is recorded, and the nameplate is where it is confirmed.

The enclosure field being A has its own consequence that is easy to overlook on a 60 Hp unit: IP20 and NEMA/UL Type 1 means the drive is protected by the cabinet, not by itself. On a drive this size the heat load is significant, so the cabinet's ventilation and clearance are part of the drive's rating rather than a detail of the panel design.

The compliance sentence stays attached to the rating rather than to the option: 600 V class below 77 A on frames 0 to 4 is declared to meet the Low Voltage Directive, with EMC compliance determined by the user. An option change does not move that boundary, which is why the two entries share it.

What this page recommends to a buyer is a two-step check rather than a decode. First, read the nameplate's full string and compare its trailing characters with the shop title, because the difference between these two entries is exactly the kind of character that gets dropped when a part number is copied by hand. Second, confirm the brake question from the wiring: a drive with braking resistor terminals landed and a resistor fitted has the option, and one with the terminals blank does not.

A replacement order should carry the full string and the duty. Two suppliers quoting the same family, voltage and rating code can be quoting two different options, and the difference only appears at commissioning, which is the most expensive place for it to appear.

The rest of the trailing block is not restated here. Communication slot, control type, feedback and documentation are each defined in their own table, and none of them is asserted from this string on this page.

No lifecycle statement and no price is implied. Everything factual on this page is the rating data shared with the other 062 entry, the enclosure definition, the brake availability rule and the class compliance sentence, all quoted from the drive family's published tables.

There is a documentation consequence to the two entries existing side by side. If both are listed with the same family, voltage and rating code and differ only at the end, then a search for the plain catalog number will find both, and a buyer has no way to tell from the listing which option the stock carries. The listing that states the full string is the only one that answers the question, which is why this page quotes the trailing characters rather than truncating them.

On an IP20 60 Hp drive the thermal question is the one that decides panel life. The cabinet has to move the losses of a drive this size, and the clearances in the drive's installation data assume it. A drive that is correctly sized and poorly ventilated ages in a way that looks like an electrical fault for about a year before it becomes one.

The other drives, reactors and drive spares in this range are collected in the Drives & Motors category. The neighbouring ratings and entries are listed at 20BE052A0AYNANA0, 20BE062A0AYNAND0, and this drive is listed at 20BE062A0ANNAND0.

Neighbouring catalog numbers in this class

Records carried by this shop whose catalog numbers share the most characters with 20BE062A0ANNAND0; nearest codes first.

Site catalogue: plc-vip.com. This page is 20BE062A0ANNAND0.

Sources. Rockwell publishes the technical data for the PowerFlex 700 range as 20B-TD001, and the installation instructions split by frame size, with 20B-IN019 covering frames 0…6 and 20B-IN014 covering frames 7…10. The ratings, current figures and ordering characters quoted on this page for 20BE062A0ANNAND0 follow those publications, and the user manual for the frames covered here is 20B-UM001.