logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 20BE017A0AYNAND0

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 20BE017A0AYNAND0

China Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier
Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier Allen Bradley PowerFlex 20BE017A0AYNAND0 supplier

Large Image :  Allen Bradley PowerFlex 20BE017A0AYNAND0

Product Details:

Place of Origin: Made in MEXICO
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 20BE017A0AYNAND0

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $2002.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 2 PCS
Detailed Product Description

20BE017A0AYNAND0

This page documents catalog number 20BE017A0AYNAND0, a PowerFlex 700 drive in the 600 V AC class at 17 A. The decode and the ratings below are taken from the drive family's published catalog number explanation and line reactor tables; the trailing option blocks are not interpreted here.

Decode and published ratings

SpecificationValue
Catalog number20BE017A0AYNAND0
Family (first three characters)20B - PowerFlex 700
Voltage class (fourth character)E - 600 V AC, three-phase
Rating code (fifth to seventh)017 - 17 A
Heavy-duty rating as published10 Hp
Normal-duty rating as publishedNo normal-duty pairing printed for this code
Input line reactor, heavy duty1321-3R12-B
Output line reactor, heavy duty1321-3R18-B
Input line reactor, normal dutyn/a
Output line reactor, normal dutyn/a
Full power range, 600 V class frames 0-4575...660 V
Operating range, 600 V class frames 0-4432...660 V
Nominal motor voltage575 V
Low voltage directive note600 V class below 77 A (frames 0-4) declared to meet the Low Voltage Directive; EMC compliance determined by the user

What the number decides and what it leaves open

Reading this number from left to right settles the two questions that decide whether a 20BE017 can replace the drive in the panel: what voltage it accepts and how much current it delivers. The first three characters are the family, 20B, which is PowerFlex 700. The fourth character is the voltage class, E, which on this platform is 600 V AC three-phase. The next three characters, 017, are the normal-duty output current in amps, written on the same convention the family uses for fractional ratings such as 2P2 for 2.2 A.

The published ratings for this code are 17 A. In the 600 V AC column of the drive's line reactor table the same code appears twice, once as a heavy-duty rating of 10 Hp and once as a normal-duty rating of 15 Hp, because PowerFlex 700 drives carry both ratings on the same hardware and the duty is selected in the drive's programming rather than in the catalog number. That distinction is the one that most often turns into an undersized drive: a machine that needs the heavy-duty figure cannot use the normal-duty number, and the catalog number looks identical either way.

The reactor table names a specific pair for this code. Heavy duty calls for 1321-3R12-B on the input side and 1321-3R18-B on the output side, normal duty for the same frame class. Where a panel already has a reactor fitted for another drive of the same frame, the pair is the check to make before assuming the existing reactor can stay.

The voltage figures that apply to the 600 V class on frames 0 to 4 are published as a full power range of 575 to 660 V and an operating range of 432 to 660 V, against a nominal motor voltage of 575 V. Below the bottom of the full power range the drive is linearly derated, which is why a 600 V drive on a 480 V system is not simply a drive running slow; it is a drive that has lost torque authority at the top of its speed range.

There is also a compliance sentence attached to this voltage class that does not appear in the same form in the 240 V and 480 V classes. Drives in the 600 V class below 77 A, which covers frames 0 to 4, are declared to meet the Low Voltage Directive, and the user is responsible for determining compliance with the EMC directive. On a 17 A drive that sentence applies, and it is the one a panel builder needs before writing a declaration of conformity for the machine.

The physical frame matters because it fixes the terminal arrangement, the heatsink clearance and the spare parts. This code sits in the lower half of the frame range, and the reactor pair above is the practical evidence of that: a frame that takes a 3R12 input reactor is not the frame that takes a 3R25.

What the remaining characters in this number encode is not restated here. The trailing blocks carry the enclosure, the brake option, the communication slot and the firmware variant, and each of those has its own table in the drive's manual. A page that guessed at them from the string would be guessing about a machine's wiring, and the cost of that guess lands on the commissioning engineer.

Two practical checks belong on this page because they are what a buyer does with it. First, confirm the nameplate rather than the shop title, because the duty selection is invisible in the catalog number and the nameplate rating is the only place it is stated for the drive in hand. Second, confirm the motor's full-load current against 17 A at the actual supply voltage, not at the nameplate voltage, because the 600 V class tolerates a wide operating band and the current at the low end of that band is not the current printed on the motor.

The alternative to this drive in the same family is not a smaller number but a different rating code: 011 for 11 A, 022 for 22 A, 027 for 27 A. Those codes change the reactor pair and the frame, which is why the substitution decision is made from the table rather than from the current alone.

No lifecycle statement is made here and no price is implied. The ratings quoted are the ones printed in the drive's own selection and reactor tables, and the compliance sentence is quoted rather than paraphrased because a paraphrase of a compliance statement is worthless in a file.

The gap between the two duty figures on this code is worth stating plainly, because it is the difference between a machine that runs and a machine that trips on overload at the first cold morning. Ten horsepower heavy duty against fifteen horsepower normal duty means the normal-duty number assumes a load whose torque falls away with speed, as a centrifugal pump's does, while the heavy-duty number assumes a load that keeps asking for torque at low speed, as a conveyor or a positive-displacement pump does.

That also explains why the reactor pair in the heavy-duty column is the one printed first. A drive applied to a constant-torque load spends its life at higher current per horsepower, and the reactor chosen for that duty is the conservative choice when the duty is unknown at the time of ordering.

A 17 A drive is a mid-range unit in a panel sense rather than a small one, and the wiring consequence is that the motor cables leave the enclosure rather than staying inside it. Cable length, shielding and the drive's own carrier frequency then matter to the installation in a way they do not on a 2.7 A auxiliary drive, and the reactor pair is the family's published answer to the harmonic question rather than a suggestion.

What a replacement order should state, if this page is being used as a reference, is the catalog number as read from the nameplate, the duty the machine actually runs, and the supply voltage measured at the panel rather than assumed from the plant's nominal. Those three together are what makes a quotation comparable, and the catalog number alone is what makes two quotations look identical when they are not.

The rest of the drives, reactors and drive spares in this range are collected in the Drives & Motors category. Numbers one step either side of this rating are listed at 20BE027A0AYNAND0, 20BE2P7A0AYNAND0, 20BE6P1A0AYNAND0, and the drive this page describes is listed at 20BE017A0AYNAND0.

Sources. Rockwell publishes the technical data for the PowerFlex 700 range as 20B-TD001, and the installation instructions split by frame size, with 20B-IN019 covering frames 0…6 and 20B-IN014 covering frames 7…10. The ratings, current figures and ordering characters quoted on this page for 20BE017A0AYNAND0 follow those publications, and the user manual for the frames covered here is 20B-UM001.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)