logo
Home ProductsAllen Bradley Other PLC

Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12

China Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier
Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12 supplier

Large Image :  Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley ArmorPoint 1738-IB8M12 / 1738IB8M12

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $117.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1738-IB8M12

This page documents the 1738-IB8M12, a 8-channel sinking dc input, M12 connectors in the ArmorPoint I/O family: a sealed IP67 block that mounts on a base spanning two backplane positions and needs no cabinet of its own. Channel count, thresholds, delay and dissipation below are taken from the module installation instructions, which is the document that fixes them per catalog number.

Published module data

FieldValue
Catalog number1738-IB8M12
Family1738 ArmorPoint I/O, 24 V dc digital input
Channels8 (1 group of 8), non-isolated, sinking
ConnectorsM12 (micro), 4 connectors with 2 inputs each
Connector pinoutPin 1 24 V dc, pin 3 common, pins 2 and 4 carry inputs 0-7 across M12-A to M12-D
Keyswitch position1
PointBus current75 mA at 5 V dc
Power dissipation1.6 W at 28.8 V dc (5.5 BTU/hr)
Data produced / consumed1 byte produced, 0 consumed (1 bit per channel)
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s

Thresholds that decide whether a sensor reads

On-state 10-28.8 V dc, nominal 24 V dc; off-state input 5 V dc maximum; on-state current 2 mA nominal, 4 mA at 24 V dc minimum, 5 mA maximum; off-state leakage 1.5 mA maximum; impedance 3.6 kohm nominal, 4.7 kohm maximum. Of those numbers the two that decide a real installation are the on-state minimum of 10 V dc and the off-state maximum of 5 V dc. A two-wire sensor with enough leakage to hold the input above 5 V while it is off reads permanently on, and the published off-state leakage ceiling of 1.5 mA is the number to compare against the sensor datasheet before the panel is wired.

Input delay is 0.5 ms hardware plus 0-63 ms selectable in the module. That means the floor is a 0.5 ms hardware delay and the filter can add up to 63 ms, which is the difference between counting a short pulse and rejecting contact bounce on a mechanical limit switch. A machine that counts parts and one that watches a safety gate want different settings from the same module, and neither wants a different catalog number.

The input is non-isolated with a 50 V rms continuous withstand between field and backplane, and the module produces one byte and consumes none. One bit per channel, 0 for off and 1 for on, is the entire interface the controller sees; the connector arrangement on the face of the module changes nothing about that byte.

Sinking, sourcing and the second spare part

This string is the sinking member of the 8-channel pair: the field device pulls the input down to common, which is the arrangement a PNP sensor needs, and the supply stays on the module side. Cross it with the sourcing member on one machine and the wiring is still legal but the spare list doubles, so the direction is fixed once per machine rather than per block.

A sinking input takes the field device to common, which is the arrangement for a PNP sensor that switches the 24 V supply. The sourcing member of this family takes the device to the supply instead. Running both on one machine is perfectly legal, but it turns one spare into two, and the spare decision is made at the catalog number rather than in the storeroom.

Micro shells with two channels each halve the number of cords and the number of sealing points compared with single-pin shells, at the cost of a cord-set fault taking two channels out together. That trade is the whole difference between the M12 and M8 strings of this block. The block is published in three shells at the same eight channels, and the electrical behaviour does not change with the shell.

The 8-channel sinking block is published in three connector shells at the same channel count: M12 micro, M23 mini and M8 pico. M8 gives eight single-pin shells and therefore eight individual cord sets, M12 gives four shells with two inputs each, and M23 gives one twelve-pin shell. The electrical behaviour is the same; the cable preparation and the number of possible sealing faults are not.

Environment and installation facts that repeat across the family

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

Mounting is part of the electrical path: the module sits on a base, the base is fixed to a grounded metal plate with #8 (M4) screws, and the ground lug is also a mounting hole. The conductive path therefore runs through the base and the plate rather than through the module, which is why a module swapped onto a dirty base measures as a missing earth and reads like an electronics fault.

The family is built so the module is the replaceable unit and the base stays on the machine. The keyswitch position on the base has to match the module class, and a module inserted one position off is not a wiring error that can be traced with a meter but a mapping error that appears as shifted channels. That is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, only the position and the adapter map.

Same class, other connector shells

The same electrical function is published under other strings in this family: 1738-IB8M23, 1738-IB8M8, 1738-IV8M12. A substitution between them is a change of shell and cord-set preparation rather than a change of channel behaviour, and the keyswitch position is what has to stay compatible with the base already on the machine.

A sealed block is not a substitute for a cabinet when the environment includes washdown or corrosive atmosphere. The IP rating covers the module and its mated connectors; it says nothing about the chemical resistance of the shell or the cable jacket.

A backplane in this family is commissioned in the order of the bases rather than by the wiring, and that is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, so the channel number a technician sees on the module face is derived from the position on the backplane and the mapping in the adapter. A module inserted one position off is not a wiring error that can be traced with a meter; it is a mapping error that appears as shifted channels.

The adapter is the only place the channel map exists. Modules publish channel counts and data bytes; the adapter publishes the order in which those bytes appear to a scanner, so a replacement module in the same position needs no map change while a module moved to a new position does.

The default data map matters as much as the rating: a digital module produces one byte and, for outputs, consumes one, and that byte is the channel status and output state the controller actually sees.

What this page does not claim matters as much as what it does. It states no cycle time, no maximum cable length and no network baud rate for this catalog number, because those belong to the segment and the adapter rather than to the module, and a figure of that kind copied into a page becomes a specification nobody can trace back to a publication. Where the source documents do fix a value - the channel count, the shell, the current limit, the isolation rating, the temperature window, the data size - it is on this page with the publication named.

No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions (1738-IN001 for dc outputs, 1738-IN002 for dc inputs, 1738-IN003 for analog inputs and the temperature input instructions) and the DeviceNet adapter user manual 1738-UM001.

Related catalog numbers in the 1738 range

Twelve of the 42 1738 records carried on this site, ordered by how close their codes sit to this one. This page is 1738-IB8M12.

This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 1738-IB8M12 page is one entry in it. It is the entry point used when a project list is assembled group by group.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)