logo
Home ProductsAllen Bradley Other PLC

Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13

China Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier
Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13 supplier

Large Image :  Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT13

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley ArmorPoint 1738-EXT3 / 1738EXT3

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $119.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1738-EXT3

This page documents catalog number 1738-EXT3, a three metre backplane bus extension unit in the ArmorPoint I/O family, Series A. It is a cable assembly with a starter and an end, not an I/O module, and the figures and application rules below are quoted from the extension unit installation instructions.

What the unit is and what it carries

FieldValue
Cable length3 m (10 ft)
Weight0.8 kg (1.76 lb) approximately
Functionextends the backplane to a second bank of I/O modules; passes backplane signals through the cable
Extension units per adapterup to four, for all adapters except 1738-ADNX
1738-ADNX exceptiononly one extension unit when there are fewer than 32 modules on the backplane
First module after the unitmust be a 1738-FPD or a 1738-EP24DC
When an EP24DC is requiredwhen additional backplane power is needed, or after two extension units
When neither is requiredwhen the segment after the unit holds only 1738-IT2IM12, IR2M12, OW4M12 or OW4M12AC modules
Cable routingbend radius not smaller than 70 mm (2.76 in.), at least 30.7 mm (1.21 in.) from the base edge before the first bend
Mounting screwsM4 (#8), minimum 12 mm (0.47 in.) at the cable starter and 40 mm (1.57 in.) at the cable end
Keyswitchstarter position, left side of the system
Enclosuremeets IP65/66/67 when marked

What the published rules mean in a project

Four extension units per adapter is the published ceiling, and the ADNX adapter is the one exception: only a single unit is allowed while the backplane holds fewer than 32 modules. A layout drawn for a DeviceNet segment therefore cannot be copied to an EtherNet/IP segment unchanged, even where the module mix is identical.

The rule that shapes the physical layout is the next one: the first module after an extension unit must be either a 1738-FPD or a 1738-EP24DC. The extension unit carries signals but not the power bus, so a module placed directly after the cable has no field power of its own. Two extension units in a row force an 1738-EP24DC rather than an FPD, because the backplane current has to be replenished as well.

There is one published exception worth knowing before adding an FPD to a plan: if the segment after the extension unit holds only 1738-IT2IM12, 1738-IR2M12, 1738-OW4M12 or 1738-OW4M12AC modules, neither an FPD nor an EP24DC is needed. Those are the temperature, relay and high-speed counter parts, and a short segment of them can follow a cable directly.

Cable routing is specified numerically rather than left to practice: a bend radius no smaller than 70 mm and at least 30.7 mm of straight cable from the base edge before the first bend. The screws differ at each end, 12 mm minimum at the starter and 40 mm minimum at the end, because the end must also hold the cable gland rather than only the base.

The length is the difference between this catalog number and its sibling: 1 m reaches a second bank across a single machine section, and 3 m crosses a frame or a conveyor line. Both carry the same signals and the same rules, and excess length is meant to be looped and tied into a wireway rather than coiled at the base.

Environment and installation facts that repeat across the family

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

Connector shells are the part of the ordering decision a drawing rarely shows. M8 is a single-pin pico shell, M12 is a four or five pin micro shell, M23 is a twelve pin shell, and the same channel count can be delivered in three different shell sizes with three different cable preparations. A plant that standardises on M12 cord sets buys the M12 variant; a plant that already runs M8 patch cables buys the M8 variant and gets the same eight channels in eight single-pin shells, and the field wiring effort differs accordingly.

Every module in this family carries a green and red module-status indicator, a network-status indicator and per-channel yellow or red status, all on the logic side, so a technician diagnoses a channel from the face of the module rather than from a wiring diagram. The catalog number covered on this page is 1738-EXT3.

What this page does not claim matters as much as what it does. It does not state a maximum backplane current for the cable itself, because the limit is the adapter or the EP24DC rating rather than the cable; only what the source publication states is printed here.

No lifecycle statement and no price is implied. The length, mounting rules and environmental figures are quoted from the ArmorPoint extension unit installation instructions, and a figure absent from this page is absent from the publication for this catalog number.

The four extension rules, and where the printed cable fit is

An extension unit carries the backplane to a second bank of modules, and the publication puts four rules around it that are all visible in the one table: four units per adapter, a first module that must be a 1738-FPD or a 1738-EP24DC, a supply required after the second unit, and one exception for the 1738-ADNX adapter.

Extension unitModules on the segmentFirst module after the unitExpansion supply
First 1738-EXT1 or 1738-EXT3no printed requirement1738-FPD or 1738-EP24DCnot required
Secondno printed requirement1738-FPD or 1738-EP24DCrequired after two units
Thirdno printed requirement1738-FPD or 1738-EP24DCrequired after two units
Fourthstill four units per adapter1738-FPD or 1738-EP24DCrequired after two units

Where this cable sits: 1738-EXT3 is the 3 m (10 ft) member of a two-length pair, and the length is the only thing that separates it from its sibling. Everything that governs how many units can be chained - four per adapter, the first-module rule, the supply after the second unit - is identical on both pages.

Two rules give the same answer from different directions: after two extension units a supply is required, and the segment after a unit must open with a 1738-FPD or a 1738-EP24DC. Both exist because the backplane current is not carried through the cable any further than that.

What the printed data does not carry: the page gives no current rating for the cable itself and no maximum total backplane length in metres, only the four-unit count. The 70 mm bend radius and the 30.7 mm clearance from the base edge are the only mechanical numbers published.

Source: Rockwell publication 1738-IN001 (extension unit installation instructions); cable length and the four-unit rule are printed on this page, the rest is the same publication rule restated.

Related catalog numbers in the 1738 range

Twelve of the 42 1738 records carried on this site, ordered by how close their codes sit to this one. This page is 1738-EXT3.

This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 1738-EXT3 page is one entry in it. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)