logo
Home ProductsAllen Bradley Other PLC

Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23

China Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier
Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23 supplier

Large Image :  Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley ArmorPoint 1738-VHSC24M23 / 1738VHSC24M23

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $208.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1738-VHSC24M23

This page documents catalog number 1738-VHSC24M23, a 24 V dc very high speed counter, M23 connector in the ArmorPoint I/O family. It is the motion end of the family: a sealed IP67 counter module with A, B and Z inputs, two outputs that can be tied to compare windows, and a 1 MHz ceiling in the counter configuration. The figures below are quoted from the installation instructions for this module.

What the module is and where it sits

FieldValue
Inputs per module1 group of A and A return, B and B return, Z and Z return
ConnectorM23, 12-pin: pins 1-6 as plus and minus A, B, Z; pins 7-8 outputs 0-1; pins 9-10 return; pin 11 24 V dc; pin 12 chassis
Input voltage15 to 24 V dc, 6.1 mA at 15 V dc and 10.2 mA at 24 V dc
Off-stateunder 1.8 V dc, 0.250 mA maximum
On-stateover 12.5 V dc, over 5 mA
Input filteroff, 10 us, 100 us, 1.0 ms, 10.0 ms
Maximum frequency1.0 MHz counter and encoder X1, 500 kHz encoder X2 and 250 kHz encoder X4 without filter
Outputs1 isolated group of 2, 0.5 A at 24 V dc each, 10 to 28.8 V dc supply
Output leakage and dropunder 0.5 mA off-state, under 0.3 V dc at 0.5 A on-state, 6 A short-circuit current with protection
Output delay25 us off-to-on and 150 us on-to-off, load dependent
Data size6 or 10 bytes produced, 2 or 4 bytes consumed
Keyswitch position2
PointBus current180 mA maximum
Power dissipation1.9 W at rated load (6.5 BTU/hr)
Dimensions31.75 x 66.80 x 107.95 mm (1.25 x 2.63 x 4.25 in.), 0.289 kg

What the published figures mean in a project

The counter modes are the configuration that matters: counter, encoder X1, X2 and X4, PWM, period and rate, continuous rate, rate measurement and pulse generator, with four store modes (store and continue, store and wait and resume, store and reset and wait and start, store and reset and start). A machine that needs a registration mark and a length on the same sensor is choosing between modes 2 and 3 rather than between two modules.

The filter selection is the second decision, and it is stated as a rate rather than a time: no filter gives the 1 MHz ceiling, 50 kHz, 5 kHz, 500 Hz and 50 Hz are the five settings, and a mechanical encoder that is filtered at 50 Hz is an encoder that cannot be read at speed. The published tolerance on the filter period is stated as a minus-only window, from minus 1.6 us at 50 kHz to minus 1.25 ms at 50 Hz.

The two outputs are isolated as one group and can be tied to any of four compare windows, with on and off values for each window, a PWM safe state and an output-control safe state. Off-state leakage under 0.5 mA and the 25 us on delay are the numbers that decide whether a solid-state relay or a small solenoid can be driven directly from the module instead of through a separate output card.

Environment and installation facts that repeat across the family

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

A backplane in this family is commissioned in the order of the bases rather than by the wiring, and that is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, so the channel number a technician sees on the module face is derived from the position on the backplane and the mapping in the adapter. A module inserted one position off is not a wiring error that can be traced with a meter; it is a mapping error that appears as shifted channels.

The keyswitch position is part of the install step, not a label: the base is rotated until the number printed for the module class lines up with the notch, and a module pressed onto a base set for another class is the failure that produces a module which powers up and never appears on the network. This page covers 1738-VHSC24M23 and its ordering options.

What this page does not claim matters as much as what it does. It does not invent a cable length, a maximum encoder distance or a scan time for this catalog number, because those follow from the device on the other end of the connector and from the segment; only what the source publication states is printed here.

No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions, and a figure absent from this page is absent from the publication for this catalog number.

PointBus budget: how many 1738-VHSC24M23 modules one segment carries

Every module in this family takes its 5 V PointBus current from the adapter, and the adapter publishes a 1.0 A budget with 1.3 A added per 1738-EP24DC. The table turns that into a module count for this page's printed draw, which is the arithmetic done when a segment is planned rather than after it browns out.

ConfigurationPointBus availableModules at 180 mAWhat that means
1738-APB or 1738-ACNR alone1,000 mA5adapter budget, no expansion supply
Adapter plus one 1738-EP24DC2,300 mA12one supply fitted after the first bank
Adapter plus two 1738-EP24DC3,600 mA20two supplies, two extra banks
63-module station, printed ceiling11340 mA at 180 mA638 expansion supplies needed

Where this module sits: 1738-VHSC24M23 draws 180 mA on the PointBus, which is band 6 of the seven published classes - 105 mA above the 75 mA class that most digital and analog modules sit in. A full 63-module station of this type is 11340 mA and needs 8 expansion supplies, which is the number to check before the module list is fixed.

Read the three capacity rows from the top down and the shape of the decision is visible: the first supply more than doubles what the adapter carries, the second adds a fixed 1.3 A again, and the 63-module ceiling has to be checked separately because it binds at a different point for each class.

What the printed data does not carry: this page prints no start-up or inrush current on the PointBus and no maximum number of modules between two power supplies, so the table sizes steady-state load only. The 5 to 17 module reach is printed for the 1738-EP24DC, not for the modules it feeds.

Source: Rockwell publication 1738-IN001, adapter and expansion power supply PointBus budgets; the module count is 1,000 mA, 2,300 mA and 3,600 mA divided by this page's printed 180 mA. No figure here is estimated.

Related catalog numbers in the 1738 range

Twelve of the 42 1738 records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 1738-VHSC24M23.

Group index: Allen Bradley Other PLC. 1738-VHSC24M23 is filed under that heading in the site's own product tree. It is the entry point used when a project list is assembled group by group.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956