logo
Home ProductsAllen Bradley Other PLC

Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23

China Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier
Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23 supplier

Large Image :  Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley ArmorPoint 1738-SSIM23 / 1738SSIM23

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $180.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1738-SSIM23

This page documents catalog number 1738-SSIM23, a synchronous serial interface absolute encoder module, M23 connector in the ArmorPoint I/O family. It is the absolute-position end of the family: a sealed IP67 module that reads any encoder speaking standard SSI over an RS-422 physical interface and puts the position word on the network as produced data. The figures below are quoted from the installation instructions for this module.

What the module is and where it sits

FieldValue
SSI channels1
Encoder typeany absolute encoder on standard SSI protocol, linear, rotary or optical distance measuring, most significant bit aligned, RS-422 clock and data
Data rate125 kHz, 250 kHz, 500 kHz, 1 MHz, 2 MHz, software selectable
Bits per word2 to 31, software selectable
Word delay16 us to 64 ms, software selectable
Word length4 bytes, 32 bits, gray or binary with gray-to-binary conversion, increasing or decreasing count, two comparator values, latching with input 0
Sensor power10 to 28.8 V dc common with field power, 0.75 A maximum with short circuit protection
Clock drive current125 mA maximum
Data size10 bytes produced, 2 bytes consumed
Keyswitch position2
PointBus current110 mA maximum
Power dissipation0.94 W at rated load
Dimensions31.75 x 66.80 x 107.95 mm (1.25 x 2.63 x 4.25 in.), 0.289 kg

What the published figures mean in a project

The bit count is software selectable from 2 to 31, which is what lets one module read a 13-bit rotary encoder and a 25-bit linear scale on the same machine without a second catalog number. The word is most significant bit aligned whatever the length, so the scaling in the controller sees a consistent value.

Word delay from 16 us to 64 ms is the setting that trades update rate against the time the encoder needs to form a position, and it is published as a dwell time rather than a maximum cable length. The RS-422 clock and data pair, with 125 mA of clock drive, is the electrical basis for a run that is limited by the sensor rather than by the module.

The module produces 10 bytes and consumes 2, and the status byte carries run, up, down and comparator states alongside the position word. Two comparator values and latching on input 0 are what make this a motion module rather than a position read: the capture happens in the module, so a fast event is timestamped at the sensor rather than at the scan.

Environment and installation facts that repeat across the family

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

Connector shells are the part of the ordering decision a drawing rarely shows. M8 is a single-pin pico shell, M12 is a four or five pin micro shell, M23 is a twelve pin shell, and the same channel count can be delivered in three different shell sizes with three different cable preparations. A plant that standardises on M12 cord sets buys the M12 variant; a plant that already runs M8 patch cables buys the M8 variant and gets the same eight channels in eight single-pin shells, and the field wiring effort differs accordingly.

ArmorPoint modules are installed by bridging two bases, which is why every mechanical figure in this family is stated with the base included rather than for the module alone. The catalog number covered on this page is 1738-SSIM23.

What this page does not claim matters as much as what it does. It does not invent a cable length, a maximum encoder distance or a scan time for this catalog number, because those follow from the device on the other end of the connector and from the segment; only what the source publication states is printed here.

No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions, and a figure absent from this page is absent from the publication for this catalog number.

PointBus budget: how many 1738-SSIM23 modules one segment carries

Every module in this family takes its 5 V PointBus current from the adapter, and the adapter publishes a 1.0 A budget with 1.3 A added per 1738-EP24DC. The table turns that into a module count for this page's printed draw, which is the arithmetic done when a segment is planned rather than after it browns out.

ConfigurationPointBus availableModules at 110 mAWhat that means
1738-APB or 1738-ACNR alone1,000 mA9adapter budget, no expansion supply
Adapter plus one 1738-EP24DC2,300 mA20one supply fitted after the first bank
Adapter plus two 1738-EP24DC3,600 mA32two supplies, two extra banks
63-module station, printed ceiling6930 mA at 110 mA635 expansion supplies needed

Where this module sits: 1738-SSIM23 draws 110 mA on the PointBus, which is band 3 of the seven published classes - 35 mA above the 75 mA class that most digital and analog modules sit in. A full 63-module station of this type is 6930 mA and needs 5 expansion supplies, which is the number to check before the module list is fixed.

Read the three capacity rows from the top down and the shape of the decision is visible: the first supply more than doubles what the adapter carries, the second adds a fixed 1.3 A again, and the 63-module ceiling has to be checked separately because it binds at a different point for each class.

What the printed data does not carry: this page prints no start-up or inrush current on the PointBus and no maximum number of modules between two power supplies, so the table sizes steady-state load only. The 5 to 17 module reach is printed for the 1738-EP24DC, not for the modules it feeds.

Source: Rockwell publication 1738-IN001, adapter and expansion power supply PointBus budgets; the module count is 1,000 mA, 2,300 mA and 3,600 mA divided by this page's printed 110 mA. No figure here is estimated.

Related catalog numbers in the 1738 range

Twelve of the 42 1738 records carried on this site, ordered by how close their codes sit to this one. This page is 1738-SSIM23.

This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 1738-SSIM23 page is one entry in it. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)