logo
Home ProductsAllen Bradley Other PLC

Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12

China Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier
Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12 supplier

Large Image :  Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley ArmorPoint 1738-OE2VM12 / 1738OE2VM12

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $181.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1738-OE2VM12

This page documents catalog number 1738-OE2VM12, a 2-channel voltage analog output, M12 connectors in the ArmorPoint I/O family. It is the voltage output of the family: a sealed IP67 module on a base bridging two positions, with the ranges, resolution, drift and load figures taken from the analog output installation instructions. The figures below are quoted from the installation instructions for this module.

What the module is and where it sits

FieldValue
Outputs per module2 single-ended, non-isolated
ConnectorM12 (micro), 2 connectors: pin 1 output (channel 0 on M12-A, channel 1 on M12-B), pin 2 24 V dc, pins 3-4 common, pin 5 no connect
Output range0 to 10 V user configurable (0 V under, 5 V over) or plus or minus 10 V user configurable (minus 0.5 V under, 5 V over), 0 V until communication is established
Resolution14 bits, 13 plus sign, 1.28 uV per count in unipolar or bipolar mode
Accuracy and drift0.1 percent of full scale at 25 degrees C, 5 ppm per degree C
Load3 mA maximum current on the output
Conversiondigital-to-analog converter, 20 us conversion rate, 24 us step response to 63 percent of full scale
Data size2 bytes produced (fault status), 4 bytes consumed
Keyswitch position4
PointBus current75 mA at 5 V dc
External supply24 V dc nominal, 10 to 28.8 V dc, 35 mA at 24 V dc including outputs at 3 mA
Isolation50 V rms, tested at 1,250 V ac rms for 60 s
Dimensions31.75 x 66.80 x 107.95 mm (1.25 x 2.63 x 4.25 in.), 0.289 kg

What the published figures mean in a project

Bipolar output is the reason to choose the voltage variant over the current one: plus or minus 10 V with a 0.5 V over-range and 5 V over-range allowance is a signal a drive or a proportional valve expects, and a 4 to 20 mA loop cannot represent a negative command at all.

The 3 mA output limit is small and it is published deliberately: this module drives high-impedance analog inputs and not a load that needs current. Driving a 1 kohm burden at 10 V already asks for 10 mA, so the input impedance of the receiving device is the number to check before the module is ordered.

Drift at 5 ppm per degree C is six times tighter than the current variant, and the reason is the absence of a current-conversion stage. Where a command has to hold across a warm cabinet, that difference is larger than the accuracy figure at 25 degrees C suggests.

Environment and installation facts that repeat across the family

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

A backplane in this family is commissioned in the order of the bases rather than by the wiring, and that is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, so the channel number a technician sees on the module face is derived from the position on the backplane and the mapping in the adapter. A module inserted one position off is not a wiring error that can be traced with a meter; it is a mapping error that appears as shifted channels.

The keyswitch position is part of the install step, not a label: the base is rotated until the number printed for the module class lines up with the notch, and a module pressed onto a base set for another class is the failure that produces a module which powers up and never appears on the network. This page covers 1738-OE2VM12 and its ordering options.

What this page does not claim matters as much as what it does. It does not invent a cable length, a loop length or a scan time for this catalog number, because those follow from the device on the other end of the connector and from the segment; only what the source publication states is printed here.

No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions, and a figure absent from this page is absent from the publication for this catalog number.

PointBus budget: how many 1738-OE2VM12 modules one segment carries

Every module in this family takes its 5 V PointBus current from the adapter, and the adapter publishes a 1.0 A budget with 1.3 A added per 1738-EP24DC. The table turns that into a module count for this page's printed draw, which is the arithmetic done when a segment is planned rather than after it browns out.

ConfigurationPointBus availableModules at 75 mAWhat that means
1738-APB or 1738-ACNR alone1,000 mA13adapter budget, no expansion supply
Adapter plus one 1738-EP24DC2,300 mA30one supply fitted after the first bank
Adapter plus two 1738-EP24DC3,600 mA48two supplies, two extra banks
63-module station, printed ceiling4725 mA at 75 mA633 expansion supplies needed

Where this module sits: 1738-OE2VM12 draws 75 mA on the PointBus, which is band 1 of the seven published classes. At 2 points that is 37.5 mA of 5 V budget per point, so a full 63-module 1738-OE2VM12 station is 4725 mA and needs 3 expansion supplies.

The count in the second column is where a segment stops, not where it fails: an adapter with 13 modules of this draw leaves the thirteenth with no margin, and the printed answer is to fit a 1738-EP24DC rather than to shorten the bank.

What the printed data does not carry: this page prints no start-up or inrush current on the PointBus and no maximum number of modules between two power supplies, so the table sizes steady-state load only. The 5 to 17 module reach is printed for the 1738-EP24DC, not for the modules it feeds.

Source: Rockwell publication 1738-IN001, adapter and expansion power supply PointBus budgets; the module count is 1,000 mA, 2,300 mA and 3,600 mA divided by this page's printed 75 mA. No figure here is estimated.

Related catalog numbers in the 1738 range

Twelve of the 42 1738 records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 1738-OE2VM12.

Group index: Allen Bradley Other PLC. 1738-OE2VM12 is filed under that heading in the site's own product tree. Reach it directly if the suffix on this record still needs confirming against a sibling.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)