This page documents catalog number 1738-OE2VM12, a 2-channel voltage analog output, M12 connectors in the ArmorPoint I/O family. It is the voltage output of the family: a sealed IP67 module on a base bridging two positions, with the ranges, resolution, drift and load figures taken from the analog output installation instructions. The figures below are quoted from the installation instructions for this module.
| Field | Value |
| Outputs per module | 2 single-ended, non-isolated |
| Connector | M12 (micro), 2 connectors: pin 1 output (channel 0 on M12-A, channel 1 on M12-B), pin 2 24 V dc, pins 3-4 common, pin 5 no connect |
| Output range | 0 to 10 V user configurable (0 V under, 5 V over) or plus or minus 10 V user configurable (minus 0.5 V under, 5 V over), 0 V until communication is established |
| Resolution | 14 bits, 13 plus sign, 1.28 uV per count in unipolar or bipolar mode |
| Accuracy and drift | 0.1 percent of full scale at 25 degrees C, 5 ppm per degree C |
| Load | 3 mA maximum current on the output |
| Conversion | digital-to-analog converter, 20 us conversion rate, 24 us step response to 63 percent of full scale |
| Data size | 2 bytes produced (fault status), 4 bytes consumed |
| Keyswitch position | 4 |
| PointBus current | 75 mA at 5 V dc |
| External supply | 24 V dc nominal, 10 to 28.8 V dc, 35 mA at 24 V dc including outputs at 3 mA |
| Isolation | 50 V rms, tested at 1,250 V ac rms for 60 s |
| Dimensions | 31.75 x 66.80 x 107.95 mm (1.25 x 2.63 x 4.25 in.), 0.289 kg |
Bipolar output is the reason to choose the voltage variant over the current one: plus or minus 10 V with a 0.5 V over-range and 5 V over-range allowance is a signal a drive or a proportional valve expects, and a 4 to 20 mA loop cannot represent a negative command at all.
The 3 mA output limit is small and it is published deliberately: this module drives high-impedance analog inputs and not a load that needs current. Driving a 1 kohm burden at 10 V already asks for 10 mA, so the input impedance of the receiving device is the number to check before the module is ordered.
Drift at 5 ppm per degree C is six times tighter than the current variant, and the reason is the absence of a current-conversion stage. Where a command has to hold across a warm cabinet, that difference is larger than the accuracy figure at 25 degrees C suggests.
| Parameter | Value |
| Dimensions with base | 120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters |
| Enclosure rating | Meets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one |
| Operating temperature | -20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock |
| Storage temperature | -40 to 85 degrees C (-40 to 185 degrees F) |
| Relative humidity | 5 to 95 percent non-condensing, IEC 60068-2-30 damp heat |
| Shock and vibration | Operating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating |
| Isolation | 50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s |
| ESD and RF immunity | 6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz |
| Transient immunity | Plus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge |
| Emissions | CISPR 11 Group 1 Class A |
| Mounting | Mounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole |
| Weight | 0.29 kg (0.64 lb) with base |
| Field power bus | 24 V dc nominal, 10 to 28.8 V dc range |
| PointBus current | 75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23 |
A backplane in this family is commissioned in the order of the bases rather than by the wiring, and that is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, so the channel number a technician sees on the module face is derived from the position on the backplane and the mapping in the adapter. A module inserted one position off is not a wiring error that can be traced with a meter; it is a mapping error that appears as shifted channels.
The keyswitch position is part of the install step, not a label: the base is rotated until the number printed for the module class lines up with the notch, and a module pressed onto a base set for another class is the failure that produces a module which powers up and never appears on the network. This page covers 1738-OE2VM12 and its ordering options.
What this page does not claim matters as much as what it does. It does not invent a cable length, a loop length or a scan time for this catalog number, because those follow from the device on the other end of the connector and from the segment; only what the source publication states is printed here.
No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions, and a figure absent from this page is absent from the publication for this catalog number.
Every module in this family takes its 5 V PointBus current from the adapter, and the adapter publishes a 1.0 A budget with 1.3 A added per 1738-EP24DC. The table turns that into a module count for this page's printed draw, which is the arithmetic done when a segment is planned rather than after it browns out.
| Configuration | PointBus available | Modules at 75 mA | What that means |
| 1738-APB or 1738-ACNR alone | 1,000 mA | 13 | adapter budget, no expansion supply |
| Adapter plus one 1738-EP24DC | 2,300 mA | 30 | one supply fitted after the first bank |
| Adapter plus two 1738-EP24DC | 3,600 mA | 48 | two supplies, two extra banks |
| 63-module station, printed ceiling | 4725 mA at 75 mA | 63 | 3 expansion supplies needed |
Where this module sits: 1738-OE2VM12 draws 75 mA on the PointBus, which is band 1 of the seven published classes. At 2 points that is 37.5 mA of 5 V budget per point, so a full 63-module 1738-OE2VM12 station is 4725 mA and needs 3 expansion supplies.
The count in the second column is where a segment stops, not where it fails: an adapter with 13 modules of this draw leaves the thirteenth with no margin, and the printed answer is to fit a 1738-EP24DC rather than to shorten the bank.
What the printed data does not carry: this page prints no start-up or inrush current on the PointBus and no maximum number of modules between two power supplies, so the table sizes steady-state load only. The 5 to 17 module reach is printed for the 1738-EP24DC, not for the modules it feeds.
Source: Rockwell publication 1738-IN001, adapter and expansion power supply PointBus budgets; the module count is 1,000 mA, 2,300 mA and 3,600 mA divided by this page's printed 75 mA. No figure here is estimated.
Twelve of the 42 1738 records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 1738-OE2VM12.
Group index: Allen Bradley Other PLC. 1738-OE2VM12 is filed under that heading in the site's own product tree. Reach it directly if the suffix on this record still needs confirming against a sibling.