This page documents the 1738-IT2IM12, a 2-channel thermocouple input with cold junction compensation, M12 connectors in the ArmorPoint I/O family. The supported sensor list, resolution, update rate and cold-junction behaviour are quoted from the RTD and thermocouple input module installation instructions.
| Field | Value |
| Catalog number | 1738-IT2IM12 |
| Family | 1738 ArmorPoint I/O, temperature input |
| Channels | 2 differential, individually isolated |
| Connectors | M12 (micro), 2 connectors |
| Input range | plus or minus 75 mV, with cold junction compensation over 0 to 70 degrees C |
| Resolution | 15 bits plus sign, 2.5 mV per count |
| Accuracy | 0.1 percent of full scale at 25 degrees C, 30 ppm per degree C drift |
| Converter | Delta Sigma, 120 dB common mode rejection, 100 dB normal mode rejection |
| Keyswitch position | 6 |
| PointBus current | 175 mA at 5 V dc |
| Power dissipation | 1.0 W maximum (3.3 BTU/hr) |
| Isolation | 50 V rms between individual channels, tested at 1,000 V rms for 1 s; input is not overvoltage protected |
| Data size | 8 bytes produced, 0 consumed |
The sensor list decides the application, and this module publishes it with a usable range for every sensor type: Type B 30 to 1820 C, Type C 0 to 2315 C, Type E -270 to 1000 C, Type J -210 to 1200 C, Type K -270 to 1372 C, Type N -270 to 1300 C, Type R -50 to 1768.1 C, Type S -50 to 1768.1 C and Type T -270 to 400 C.
A catalog number that supports one curve is a spare part; a module carrying this list is the channel a plant standardises on when one area already runs Pt 100 and another runs Ni 120. The list is also the reason a substitution between temperature modules has to be checked curve by curve rather than by channel count.
Update rate follows the notch chosen for the line frequency: 20 ms at a 50 Hz notch, 17 ms at 60 Hz (default), 10 ms at 100 Hz, 8 ms at 120 Hz, 5 ms at 200 Hz, 4 ms at 240 Hz, 3 ms at 300 Hz, 3 ms at 400 Hz and 2 ms at 480 Hz. Step response is same ladder as the update rate, from 20 ms to 2 ms, so the module settles faster as the notch moves up the ladder, and a slow reading at 50 Hz is a setting rather than a fault.
Data size is 8 bytes produced, 0 consumed, and the isolation figure is 50 V rms between individual channels, tested at 1,000 V rms for 1 s; input is not overvoltage protected. Note the absence of input protection: a sensor lead that sees a supply is a damaged channel rather than a recoverable fault, so field wiring on a temperature block is checked before power is applied.
| Parameter | Value |
| Dimensions with base | 120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters |
| Enclosure rating | Meets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one |
| Operating temperature | -20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock |
| Storage temperature | -40 to 85 degrees C (-40 to 185 degrees F) |
| Relative humidity | 5 to 95 percent non-condensing, IEC 60068-2-30 damp heat |
| Shock and vibration | Operating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating |
| Isolation | 50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s |
| ESD and RF immunity | 6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz |
| Transient immunity | Plus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge |
| Emissions | CISPR 11 Group 1 Class A |
| Mounting | Mounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole |
| Weight | 0.29 kg (0.64 lb) with base |
| Field power bus | 24 V dc nominal, 10 to 28.8 V dc range |
| PointBus current | 75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23 |
Mounting is part of the electrical path: the module sits on a base, the base is fixed to a grounded metal plate with #8 (M4) screws, and the ground lug is also a mounting hole. The conductive path therefore runs through the base and the plate rather than through the module, which is why a module swapped onto a dirty base measures as a missing earth and reads like an electronics fault.
The family is built so the module is the replaceable unit and the base stays on the machine. The keyswitch position on the base has to match the module class, and a module inserted one position off is not a wiring error that can be traced with a meter but a mapping error that appears as shifted channels. That is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, only the position and the adapter map.
The family is designed so that the module is the replaceable unit and the base stays on the machine. That is why the base is ordered with the module, why the keyswitch on the base has to match the module class, and why the ground lug is also a mounting hole: the conductive path runs through the base and the plate rather than through the module. Swapping a module onto a dirty base is the failure that looks like a module fault and measures as a missing earth.
Service on a sealed block is a connector job rather than a terminal job: the cord sets come off, the module comes off the base, and the base stays bolted to the machine. That is why the spare is a module rather than a complete assembly, and why a cord-set keying mistake shows up as a channel swap instead of a wiring error a meter can find.
Two spares cover most of this family: one digital input block and one digital output block, both in the connector shell the plant already uses. The shells are not interchangeable with the existing cable preparation, so the spare has to match the shell on the machine rather than only the channel count.
The mounting base ships with the module, so a spare is ordered as a module and arrives with the metal that does the grounding; a panel that keeps bases in stock and swaps only modules is a panel that still has the old base under the new part.
What this page does not claim matters as much as what it does. It states no cycle time, no maximum cable length and no network baud rate for this catalog number, because those belong to the segment and the adapter rather than to the module, and a figure of that kind copied into a page becomes a specification nobody can trace back to a publication. Where the source documents do fix a value - the channel count, the shell, the current limit, the isolation rating, the temperature window, the data size - it is on this page with the publication named.
No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions (1738-IN001 for dc outputs, 1738-IN002 for dc inputs, 1738-IN003 for analog inputs and the temperature input instructions) and the DeviceNet adapter user manual 1738-UM001.
Twelve of the 42 1738 records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 1738-IT2IM12.
Group index: Allen Bradley Other PLC. 1738-IT2IM12 is filed under that heading in the site's own product tree.