This page documents the 1738-IE2CM12, a 2-channel current analog input, M12 connectors in the ArmorPoint I/O family: the analog front end as a sealed IP67 block on a base spanning two positions. Signal range, resolution, accuracy, impedance and data size come from the analog input module installation instructions.
| Field | Value |
| Catalog number | 1738-IE2CM12 |
| Family | 1738 ArmorPoint I/O, analog input |
| Channels | 2 single-ended, non-isolated |
| Connectors | M12 (micro), 2 connectors |
| Signal range | 4-20 mA and 0-20 mA, user configurable |
| Resolution | 16 bits over 0-21 mA, 0.32 uA per count |
| Accuracy | 0.1 percent of full scale at 25 degrees C, 30 ppm per degree C drift |
| Input impedance | 60 ohm input impedance, 60 ohm input resistance |
| External supply | 10 mA at 24 V dc external supply |
| Keyswitch position | 3 |
| PointBus current | 75 mA at 5 V dc |
| Power dissipation | 0.6 W at 28.8 V dc (2.0 BTU/hr) |
| Data size | 6 bytes produced (scanner Rx), no consumed data |
This module publishes both: 16 bits over 0-21 mA, 0.32 uA per count, and 0.1 percent of full scale at 25 degrees C, 30 ppm per degree C drift. Sixteen bits over a 0...21 mA span is fine resolution attached to a 0.1 percent accuracy statement, and a page that quotes only the bits overstates what a control loop can hold. The per-degree drift is the figure a plant engineer needs when a reading has to stay put across a shift, because it converts into a microamp error per ten degrees of panel temperature rather than an accuracy that only holds at 25 C.
Input impedance is 60 ohm input impedance, 60 ohm input resistance, which sets how much burden this channel adds to a 4...20 mA transmitter, and the external supply draws 10 mA at 24 V dc external supply. Those two together decide whether a two-wire transmitter can be loop-powered from the segment or needs its own supply.
The digital filter time constant is adjustable from 0 to 10,000 ms with a default of 0 ms, and the notch is set to the line frequency in use: 60 Hz gives a 15.7 Hz notch, 50 Hz gives 13.1 Hz, 250 Hz gives 65.5 Hz and 500 Hz gives 131 Hz. Step response follows the notch from 70 ms at 60 Hz down to 8 ms at 500 Hz, and the module update rate runs from 100 ms to 12 ms on the same ladder.
Common-mode rejection is 120 dB and normal-mode rejection is minus 60 dB. Those figures are what make a milliamp loop readable next to a contactor, and they depend on the earth-grounded metal rings in the connectors, so the shield decision is part of commissioning rather than cosmetic.
The current-input member of the pair takes 4...20 mA and 0...20 mA; the voltage member is the one a 0...10 V transducer needs. Both are two-channel blocks with the same M12 shell, the same keyswitch position and the same data size, so a machine that mixes milliamp and voltage sensors carries two part numbers for one function, and the second number is a purchase order line rather than a design decision.
| Parameter | Value |
| Dimensions with base | 120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters |
| Enclosure rating | Meets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one |
| Operating temperature | -20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock |
| Storage temperature | -40 to 85 degrees C (-40 to 185 degrees F) |
| Relative humidity | 5 to 95 percent non-condensing, IEC 60068-2-30 damp heat |
| Shock and vibration | Operating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating |
| Isolation | 50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s |
| ESD and RF immunity | 6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz |
| Transient immunity | Plus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge |
| Emissions | CISPR 11 Group 1 Class A |
| Mounting | Mounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole |
| Weight | 0.29 kg (0.64 lb) with base |
| Field power bus | 24 V dc nominal, 10 to 28.8 V dc range |
| PointBus current | 75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23 |
Mounting is part of the electrical path: the module sits on a base, the base is fixed to a grounded metal plate with #8 (M4) screws, and the ground lug is also a mounting hole. The conductive path therefore runs through the base and the plate rather than through the module, which is why a module swapped onto a dirty base measures as a missing earth and reads like an electronics fault.
The family is built so the module is the replaceable unit and the base stays on the machine. The keyswitch position on the base has to match the module class, and a module inserted one position off is not a wiring error that can be traced with a meter but a mapping error that appears as shifted channels. That is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, only the position and the adapter map.
The same electrical function is published under other strings in this family: 1738-IE2VM12, 1738-IE4CM12. A substitution between them is a change of shell and cord-set preparation rather than a change of channel behaviour, and the keyswitch position is what has to stay compatible with the base already on the machine.
Connector shells are the part of the ordering decision a drawing rarely shows. M8 is a single-pin pico shell, M12 is a four or five pin micro shell, M23 is a twelve pin shell, and the same channel count can be delivered in three different shell sizes with three different cable preparations. A plant that standardises on M12 cord sets buys the M12 variant; a plant that already runs M8 patch cables buys the M8 variant and gets the same eight channels in eight single-pin shells, and the field wiring effort differs accordingly.
The environmental claims in this family are stated per module and per connector: IP65/66/67 applies when the connector caps are tightened, and the installation instructions repeat the attention note that all connectors and caps have to be securely tightened to keep the seal. That single step is where most field failures on sealed I/O originate, and it is a mechanical check rather than a network check.
Base torque is a published value rather than a habit: 7.5 in-lb in aluminium and 16 in-lb in steel for the #8 (M4) mounting screws, and the ground lug doubles as a mounting hole. A base fixed at the wrong torque in aluminium either loses its earth path or strips the thread.
Field power and PointBus power are two separate budgets. The bus current listed for each module is drawn at 5 V dc from the adapter, and the field power at 10 to 28.8 V dc is what the sensors and the loads take; a segment planned on one of them and commissioned on the other trips on the one that was not counted.
What this page does not claim matters as much as what it does. It states no cycle time, no maximum cable length and no network baud rate for this catalog number, because those belong to the segment and the adapter rather than to the module, and a figure of that kind copied into a page becomes a specification nobody can trace back to a publication. Where the source documents do fix a value - the channel count, the shell, the current limit, the isolation rating, the temperature window, the data size - it is on this page with the publication named.
No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions (1738-IN001 for dc outputs, 1738-IN002 for dc inputs, 1738-IN003 for analog inputs and the temperature input instructions) and the DeviceNet adapter user manual 1738-UM001.
Twelve of the 42 1738 records carried on this site, ordered by how close their codes sit to this one. This page is 1738-IE2CM12.
This listing is filed in the Allen Bradley Other PLC group on plc-vip.com; the group index is Allen Bradley Other PLC catalogue index, and the 1738-IE2CM12 page is one entry in it. Reach it directly if the suffix on this record still needs confirming against a sibling.