Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR supplier

Large Image :  Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley ArmorPoint 1738-AENTR / 1738AENTR

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $376.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1738-AENTR

This page documents catalog number 1738-AENTR, the dual port EtherNet/IP adapter for the ArmorPoint I/O family, Series B. It is the head of a sealed IP67 backplane with an embedded two-port switch, and the figures below are quoted from the dual port adapter installation instructions.

What the adapter is and what it carries

FieldValue
Expansion capacity63 modules maximum; 5 rack-optimized connections for digital modules only and 31 direct connections
Backplane current0.8 A at 5 V dc from the adapter, extendable with 1738-EP24DC backplane extension power supplies and 1738-FPD modules
Supply input24 V dc at 500 mA or 12 V dc at 1.0 A, range 10 to 28.8 V dc, reverse polarity protected, inrush 6 A for 10 ms
Field side power24 V dc at 10 A maximum supplied, 10 to 28.8 V dc at 9 A delivered
POINTBus output5 V dc at 0.8 A maximum
Ethernet ports2, configured as an embedded switch, with 2-port pass-through
Ethernet10/100 Mbit/s half or full duplex, M12 D-coded female, Category 5 shielded or unshielded cable, star, tree, daisy chain and ring topologies
Isolation50 V continuous basic insulation, type tested at 500 V ac for 60 s between communications and system, communications and user power, user power and system, user power and ground, system and ground
Indicatorsmodule, network and POINTBus status on the CPU, network activity, two link activity indicators on the base, and system and adapter power on the converter
Power connectors4-pin mini male: pin 1 user power plus, pin 2 adapter power plus, pin 3 adapter power minus, pin 4 user power minus
Dimensions112 x 123 x 67 mm (4.41 x 4.84 x 2.64 in.), 0.33 kg (0.72 lb)
Enclosuremeets IP65/66/67/69K when marked
Module locationstarter module at the left side of the 1738 system
Accessoriesships with a terminating base for the last I/O module; auxiliary power cable as standard cordset 889N-F4AFC-6F or patchcord 889N-F4AFNU-6F

Power budgeting: the table an engineer works from

The adapter publication prints the PointBus current of every module in the family, and that table is the one a segment is planned from. The values below are the ones that differ from the 75 mA baseline:

ModulePointBus current at 5 V dc
1738-IB4DM1250 mA
1738-IB2M12, IB4M12, IB4M8, IB8M8, IB8M12, IB8M23, IB16DM12, IV4M12, IV8M8, IV8M12, IV8M2375 mA
Digital and analog output and input modules listed at 75 mA, including OB2EM12, OB4EM8, OB4EM12, OB8EM8, OB8EM12, OB8EM23, OB2EPM12, OV4EM12, IE2CM12, IE4CM12, IE2VM12, OE2CM12, OE4CM12, OE2VM1275 mA
1738-8CFGM8, 8CFGM23, 8CFGDLXM8, 8CFGDLXM12, 8CFGDLXM23, 8CFGM12100 mA
1738-VHSC24M23110 mA
1738-OB16E25DS, OB16E19M23, OB16EM12150 mA
1738-IJM23160 mA
1738-IT2IM12175 mA
1738-IR2M12220 mA

What the published figures mean in a project

The difference between this adapter and the single-port version is the embedded switch: two D-coded M12 ports that pass traffic through, which is what makes a daisy chain or a ring possible without an external switch in a washdown area. A star or tree still works, so the two-port part is the one that covers every topology with one catalog number.

The price of the second port is power. The single-port adapter supplies 1.0 A at 5 V dc to the backplane and this one supplies 0.8 A, and the difference is the switch and the second PHY. On a segment of analog and specialty modules that draw 75 to 220 mA each, 0.8 A accommodates eight to ten modules before an extension power supply is needed, so the two-port decision is taken together with the module list rather than after it.

Ring topology is a resilience decision and it has a cost that is not in the adapter data: a ring needs both ports connected and a supervisor that understands the topology, and the recovery behaviour belongs to the network design rather than to the module. What the module contributes is the embedded switch and the two link indicators that show which side of the ring is down.

Physical size is the other visible difference: 123 mm wide instead of 65 mm, because the second port and its connector sit beside the first. On a machine frame where the backplane runs along a rail, that extra 58 mm is a mounting decision that is easier to take before the bases are drilled than after.

The terminating base belongs at the end of the backplane in both adapters, and the auxiliary power cable is a standard 889N cordset rather than a special part, which matters in a plant that keeps those on the shelf. Isolation here is 50 V continuous with a 500 V ac type test, and a 10 ms interruption at 10 V with full load stays inside specification.

Environment and installation facts that repeat across the family

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

The family is designed so that the module is the replaceable unit and the base stays on the machine. That is why the base is ordered with the module, why the keyswitch on the base has to match the module class, and why the ground lug is also a mounting hole: the conductive path runs through the base and the plate rather than through the module. Swapping a module onto a dirty base is the failure that looks like a module fault and measures as a missing earth.

The default data map matters as much as the rating: a digital module produces one byte and, for outputs, consumes one, and that byte is the channel status and output state the controller actually sees.

What this page does not claim matters as much as what it does. It does not state a cable length, a ring recovery time or a scan rate for this adapter, because those follow from the network design rather than from the catalog number; only what the source publication states is printed here.

No lifecycle statement and no price is implied. The capacity, power and isolation figures are quoted from the ArmorPoint I/O dual port EtherNet/IP adapter installation instructions, and a figure absent from this page is absent from the publication for this catalog number.

Related catalog numbers in the 1738 range

This page links twelve of the 42 1738 records on this site; the closest rating codes come first. This page is 1738-AENTR.

For the surrounding range, open the Allen Bradley Other PLC catalogue index — 1738-AENTR is listed there beside the rest of the other-PLC group. Sibling codes of the same group are one click away from that page.

Sources. Rockwell publishes the ArmorPoint I/O installation instructions as 1738-IN014, the EtherNet/IP adapter user manual as 1738-UM005 and the family user manual as 1738-UM001. The adapter role, node capacity and connector types quoted on this page for 1738-AENTR follow those publications.

Data sources: the adapter and redundancy rows quoted on this page for 1738-AENTR follow 1738-UM001 (ArmorPoint I/O user manual) and 1738-IN014 (ArmorPoint I/O installation instructions); nothing here is inferred from the catalog string.