Product Details:
Payment & Shipping Terms:
|
9307-FTEMMDBCENE is a number in the FactoryTalk EnergyMetrix ordering block, printed by Rockwell as FactoryTalk EnergyMetrix Manager, 10 Meter Limit, Single Client SQL License.
The Manager with one client access to the bundled database - the shape most first installations take, because it removes the need to buy SQL Server separately.
Quick answer. 9307-FTEMMDBCENE is a software catalogue number: FactoryTalk EnergyMetrix, FactoryTalk EnergyMetrix Manager, 10 Meter Limit, Single Client SQL License, a single-client SQL licence included, English. Delivery: Electronic licence (no media kit in this SKU).
| 9307-FTEM10 | 10 Meter Bundle | ASK FOR STOCK |
| 9307-FTEM100 | 100 Meter Bundle | ASK FOR STOCK |
| 9307-FTEM50 | 50 Meter Bundle | ASK FOR STOCK |
| 9307-FTEM500 | 500 Meter Bundle | ASK FOR STOCK |
| 9307-FTEMCHT | Charts Plus reporting package | ASK FOR STOCK |
| 9307-FTEMMDBCENE | Manager, 10 Meter Limit, Single Client SQL License | ASK FOR STOCK |
| 9307-FTEMMDBPENE | Manager, 10 Meter Limit, Unlimited Client SQL License | ASK FOR STOCK |
| 9307-FTEMMENE | Manager, 10 Meter Limit, No SQL License | ASK FOR STOCK |
| 9307-FTEMOPC | OPC license, OPC meters unlimited (requires additional meter bundles) | ASK FOR STOCK |
| 9307-FTEMRPT | Reports Plus reporting package | ASK FOR STOCK |
| 9307-FTEMRT | Real Time reporting package | ASK FOR STOCK |
| 9307-RSP32LXRENE | RSPower32 Runtime bundled with communication drivers | ASK FOR STOCK |
| 9307-RSP32LXWENE | RSPower32 Works bundled with communication drivers | ASK FOR STOCK |
| 9307-RSP32RENE | RSPower32 Runtime | ASK FOR STOCK |
| 9307-RSP32WENE | RSPower32 Works | ASK FOR STOCK |
Catalog number |
9307-FTEMMDBCENE |
Manufacturer |
/ |
Software family |
FactoryTalk EnergyMetrix |
Package / role |
FactoryTalk EnergyMetrix Manager, 10 Meter Limit, Single Client SQL License |
Licence metric |
a single-client SQL licence included |
Language |
English |
Delivery |
Electronic licence (no media kit in this SKU) |
Included with this SKU |
FactoryTalk EnergyMetrix Manager, 10 Meter Limit, Single Client SQL License |
Ordering block |
9307 EnergyMetrix / RSPower |
Source |
Rockwell Software Product Catalog (ftalk-ca001), Asset Management section, FactoryTalk EnergyMetrix and RSPower ordering blocks |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications Rockwell Software Product Catalog - EnergyMetrix and RSPower ordering blocks (ftalk-ca001) (module specifications) and Rockwell Software Product Catalog - EnergyMetrix and RSPower ordering blocks (ftalk-ca001) (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
9307-FTEMMDBCENE appears in the FactoryTalk EnergyMetrix ordering block, where Rockwell prints it as the FactoryTalk EnergyMetrix Manager with a 10 meter limit and a single-client SQL licence.
9307-FTEMMDBCENE is the Manager with one client access to the bundled database, the shape most first installations take because it removes the need to buy SQL Server separately.
Delivery is electronic: the number is an activation rather than a box, and no media kit is part of the SKU.
EnergyMetrix captures, analyses, stores and shares energy data across a plant network, and the block is built so that a site can start with ten meters and grow the model rather than replace the software.
The Manager is the server in this model: it holds the meters, the history and the SQL database, and the three Manager numbers in the block differ mainly by which database licence they include.
This number is FactoryTalk EnergyMetrix Manager, 10 Meter Limit, Single Client SQL License, and the catalogue description fixes that role rather than leaving it to installation.
Ten meters are included with the Manager, and the meter bundles are cumulative: a site that needs 60 meters orders a 50 bundle on top of the ten, and a site that needs 400 combines the bundles printed in the block.
Rockwell prints the counters separately so a plant can grow one dimension at a time; a site that buys capacity it cannot yet use pays maintenance on points it has not commissioned.
The three Manager numbers differ by database licence: none, a single-client SQL licence, or an unlimited-client SQL licence. That choice decides whether the site supplies SQL Server itself.
Concurrent and node-locked forms are printed in this catalogue family where they exist; this page states the mode printed in the number's own description and nothing beyond it.
This is an older Rockwell software family, so the page prints no lifecycle conclusion of its own; availability is confirmed against the record of this listing at the time of the enquiry.
The useful pre-order check is the plant's actual meter count and the database it already runs, because both decide which number in this block is correct far more often than the software version does.
What is 9307-FTEMMDBCENE?
9307-FTEMMDBCENE is FactoryTalk EnergyMetrix Manager, 10 Meter Limit, Single Client SQL License, in Rockwell's 9307 software block.
What does it license?
A single-client sql licence included.
How do meters and bundles combine?
Rockwell states the meter packages are cumulative: the bundle adds its count on top of what is already licensed.
Which database do I need?
The number without a SQL licence expects the site to supply SQL Server; the other two include a single-client or unlimited-client SQL licence.
Is it a box or an activation?
An activation: the 9307 numbers are electronic, with no media kit in the SKU.
What should I quote?
The exact number 9307-FTEMMDBCENE, the current meter count and the Manager number it will sit beside.
Other numbers in the same Studio 5000 / RSLogix licence block. Same software family, different edition, option or language form - read the letters after the hyphen before you order.
9307-FTEM10 (10 Meter Bundle) · 9307-FTEM100 (100 Meter Bundle) · 9307-FTEM50 (50 Meter Bundle) · 9307-FTEM500 (500 Meter Bundle) · 9307-FTEMCHT (Charts Plus reporting package) · 9307-FTEMMDBPENE (Manager, 10 Meter Limit, Unlimited Client SQL License) · 9307-FTEMMENE (Manager, 10 Meter Limit, No SQL License) · 9307-FTEMOPC (OPC license, OPC meters unlimited (requires additional meter bundles)) · 9307-FTEMRPT (Reports Plus reporting package)
Browse the Allen-Bradley software and licences category for the other models, options and spare parts that share this range.