Product Details:
Payment & Shipping Terms:
|
2711-NC13 is RS-232 operating/programming cable from the PanelView Standard accessory range: 16.4 foot (5.0 m) RS-232 Operating/Programming Cable.
It is ordered by this catalog number and matched to the terminal series printed on the nameplate.
| 2711-NC22 | 49.0 foot (15.0 m) RS-232 Operating Cable for PanelView to MicroLogix | IN STOCK |
| 2711-NC21 | 16.4 foot (5.0 m) RS-232 Operating Cable for PanelView to MicroLogix | IN STOCK |
| 2711-NC14 | 32.7 foot (10.0 m) RS-232 Operating/Programming Cable | IN STOCK |
| 2711-NC13 | 16.4 foot (5.0 m) RS-232 Operating/Programming Cable | IN STOCK |
| 2711-CBL-HM10 | 32.7 foot (10.0 m) RS-232 Operating Cable | IN STOCK |
| 2711-CBL-PM05 | 16.4 foot (5.0 m) RS-232 Operating/Programming Cable | IN STOCK |
| 2711-CBL-PM10 | 32.7 foot (10.0 m) RS-232 Operating/Programming Cable | IN STOCK |
| 2711-CBL-HM05 | 16.4 foot (5.0 m) RS-232 Operating Cable | IN STOCK |
Application |
2711 PanelView Standard Terminal Accessories, 16.4 foot (5.0 m) RS-232 Operating/Programming Cable |
Cat Num |
2711-NC13 |
Brand Name |
Rockwell |
Product Type |
RS-232 operating/programming cable |
Length |
16.4 ft (5.0 m) |
Use |
Operating and programming |
Lifecycle |
Discontinued December 30, 2024 |
Replacement |
No planned Rockwell replacement |
2711-NC13 is a PanelView Standard communication cable.
A 9-pin male D-shell to 9-pin male D-shell RS-232 cable, 5 m (15 ft), for the DF1/RS-232 port of a PanelView 300 to 1400 terminal. It reaches the Channel 0 port of an SLC 5/03 (and 5/04, 5/05) or the RS-232 port of a computer or printer; for DH-485 point-to-point to an SLC it is the cable Rockwell lists alongside 2711-NC14 and 2706-NC13.
One restriction matters on older hardware: do not use 2711-NC13 on a PanelView 550, because pin 8 of that terminal's RS-232 connector is pulled high and the cable ties pin 8 through. Use it on the 300, 600, 900, 1000 and 1400 terminals, and on the 550 use the alternative Rockwell lists for that model.
When the SLC Channel 0 is used for DH-485, it has to be configured for DH-485 with RSLogix 500 or AI500 before the cable will pass anything - the cable does not set the protocol. Maximum DF1 full-duplex length is 15.24 m (50 ft), so the 5 m version leaves room for a second segment.
Cable type, length and port assignment per Rockwell publication 2711-UM014 (cable chart and RS-232 cable tables); the 15.24 m (50 ft) DF1 full-duplex limit is stated in the same publication's RS-232/DF1 Port Connector section.
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2711-UM014 (module specifications) and 2711-TD007 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Official Rockwell description: 2711 PanelView Standard Terminal Accessories, 16.4 foot (5.0 m) RS-232 Operating/Programming Cable.
The cable is the programming and operating link between a PanelView Standard terminal and a controller or a laptop: RS-232, with the connector style fixed by the catalog number.
Length: 16.4 ft (5.0 m).
Use: Operating and programming.
Rockwell Automation discontinued 2711-NC13 on December 30, 2024; replacement category: No planned Rockwell replacement.
This is a standard-range accessory, and the terminals it serves are themselves out of production, so the spare is either bought from remaining stock or the whole front is replaced by a PanelView Plus unit with its own accessory numbering.
Length is the only difference inside a family (5 m and 10 m, or 5 m and 15 m), so the installed cable run decides which number is ordered.
The operating cable carries the runtime link to the controller; the operating/programming cable can also be used to download the application. They are not the same wiring.
The page states the catalog number, the terminal series it fits and the published discontinuation date; nothing else is presented as specification.
A photograph of the terminal nameplate beside the old part settles the match, because both the screen size and the series letter belong to the identity of the part.
The row in red in the table at the top is the item on this page; the other rows are the rest of the same family carried by this site.
What is 2711-NC13?
2711 PanelView Standard Terminal Accessories, 16.4 foot (5.0 m) RS-232 Operating/Programming Cable.
What does 2711-NC13 fit?
16.4 ft (5.0 m).
Is 2711-NC13 discontinued?
Rockwell discontinued it on December 30, 2024; replacement category: No planned Rockwell replacement.
Can 2711-NC13 be replaced by another catalog number in the same family?
No: the family is split by screen size, series letter or cable length, and each number holds its own place in it.
What has to be checked before ordering 2711-NC13?
The terminal nameplate: model, series letter and, for a cable, the installed run length.
| Cable | Ends | Length | Use | Where it reaches |
| 2711-CBL-HM05 | 8-pin mini-DIN both ends, right-angle | 16.4 ft (5.0 m) | Operating link | Port 2 of a 1761-NET-AIC, DH-485 side |
| 2711-CBL-HM10 | 8-pin mini-DIN both ends, right-angle | 32.7 ft (10.0 m) | Operating link | Port 2 of a 1761-NET-AIC, DH-485 side |
| 2711-CBL-PM05 | 9-pin D-shell to 8-pin mini-DIN | 16.4 ft (5.0 m) | Operating and programming | PC serial port or Port 1 of a 1761-NET-AIC |
| 2711-CBL-PM10 | 9-pin D-shell to 8-pin mini-DIN | 32.7 ft (10.0 m) | Operating and programming | PC serial port or Port 1 of a 1761-NET-AIC |
| 2711-NC13 | 9-pin male D-shell both ends | 16.4 ft (5.0 m) | Operating and programming | Terminal DF1 port to Channel 0 of an SLC 5/03, 5/04 or 5/05 |
| 2711-NC14 | 9-pin male D-shell both ends | 32.7 ft (10.0 m) | Operating and programming | Terminal DF1 port to Channel 0 of an SLC 5/03, 5/04 or 5/05 |
Where this cable sits: 2711-NC13 is the 5 m member of the D-shell pair and the shortest route from a PanelView terminal DF1 port to Channel 0 of an SLC 5/03, 5/04 or 5/05. It shares its connector type with the PM cables but not its far end: NC is terminal to controller, PM is terminal to computer or coupler.
Connector type, not length, is the first filter: mini-DIN both ends for the coupler Port 2, D-shell to mini-DIN for a computer or Port 1, D-shell both ends for a controller Channel 0.
What the printed data does not carry: none of the six cables prints a conductor gauge, a shielding class or a temperature rating, and the two NC cables carry the PanelView 550 restriction - pin 8 of that terminal is pulled high, so the NC pair must not be used on a 550 even though the connector fits.
Source: Rockwell publication 2711-UM014, cable chart and RS-232 cable tables. Attribute values above are reproduced from the manufacturer's product data; nothing in this block is estimated.
The Allen-Bradley PanelView 2711 HMI terminals category lists the terminals these cables fit, together with the bezels, overlays and CompactFlash spares for the same range.