Product Details:
Payment & Shipping Terms:
|
The 2711P-RVT12 is Solar visor for the PanelView Plus range: Solar Visor for PanelView Plus and PanelView Plus CE 1250 High-bright Display Module.
this is a mechanical accessory, not electronics: it shades a high-bright display so the operator can read it in direct sun
| 2711P-RVT12 | Solar Visor for PanelView Plus and PanelView Plus CE 1250 High-bright Display Module | IN STOCK |
Application |
Solar Visor for PanelView Plus and PanelView Plus CE 1250 High-bright Display Module |
Cat Num |
2711P-RVT12 |
Brand Name |
Rockwell |
Product Type |
Solar visor |
Fits |
PanelView Plus and PanelView Plus CE 1250 high-bright display module |
Lifecycle |
Discontinued December 30, 2022 |
Replacement |
No planned Rockwell replacement |
Fits Family |
See application line |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2711P-UM006 (module specifications) and 2711P-TD001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Official Rockwell description: Solar Visor for PanelView Plus and PanelView Plus CE 1250 High-bright Display Module.
Spare-part role: this is a mechanical accessory, not electronics: it shades a high-bright display so the operator can read it in direct sun.
This item, 2711P-RVT12, is ordered by this catalog number alone; no terminal order is required, and the part is a service item, not a kit that includes a display or a logic module.
Fits: PanelView Plus and PanelView Plus CE 1250 high-bright display module.
Rockwell Automation discontinued 2711P-RVT12 on December 30, 2022; the replacement category published for it is: No planned Rockwell replacement.
A discontinued spare is bought for one of three reasons: the machine is still in production and must keep the same front, the line is being cloned, or the panel is waiting for a planned migration and needs to run until then.
Check the terminal-side catalog number before ordering a replacement: a display module must match the input style of the front it sits on, and a logic module must match the power input (AC or DC) of the panel it serves.
The visor is a mechanical part: it mounts on the high-bright display module and shades the screen from direct sunlight without changing the panel cutout.
A standard display does not accept this visor; the high-bright module has its own bezel geometry.
The part number, not the terminal model, is what identifies 2711P-RVT12; a photograph of the old part and the terminal nameplate settle the match.
For a logic module, confirm the power input letter (A or D) and the operating-system digit (8 or 9) before ordering; for a display module, confirm the input style (touch, keypad, keypad/touch) and whether the terminal is standard, marine or high-bright. 2711P-RVT12 is the exact string those fields have to match.
Ask for the date code when the part is a service exchange: an aged electrolytic or a lamp with run hours already on it costs the same as a fresh unit but fails sooner.
The table lists every catalog number of this part family that this site carries, with the official one-line description; the row in red is the item on this page.
Parts within one family are not interchangeable across rows: the description carries the size, the input style or the certification that separates them.
What is 2711P-RVT12?
Solar Visor for PanelView Plus and PanelView Plus CE 1250 High-bright Display Module.
Which display does 2711P-RVT12 fit?
Only the 1250 high-bright display module.
Is 2711P-RVT12 still available?
Rockwell discontinued it on December 30, 2022.
Does 2711P-RVT12 change the panel cutout?
No. It is an add-on over the existing bezel.
What problem does 2711P-RVT12 solve?
Direct sunlight washing out a high-bright screen; the visor shades the glass without covering the operator's view.
2711P-RVT12 is a PanelView Plus 6 catalog number. The range is built as 400, 600, 700, 1000, 1250 and 1500 display classes, each in touch, keypad and keypad plus touch builds, with AC or DC input and two feature sets, and every catalog number decodes into those positions.
| Attribute | Value |
| Catalog number | 2711P-RVT12 |
| Family | PanelView Plus 6, 2711P |
| Models in range | 400, 600, 700, 1000, 1250, 1500 display classes |
| Input builds | T touch, K keypad, B keypad plus touch |
| Power and features | A8 AC input, D8 DC input, 9 suffix for the extended Windows CE feature set |
| Detail source | 2711P-UM006 PanelView Plus 6 terminals |
Where this catalog number is not described in the current accessory or terminal table, its identity has to be read from the current literature before it is ordered or substituted: the replacement part family in this range has changed content across series, and a number that looks like a display part can be mounting hardware or a backlight.
The 400 and 600 terminals and the 700 to 1500 terminals are two different platforms inside one bulletin: the small terminals use category five twisted pair and a standard or crossover lead such as 2711P-CBL-EX04 for a direct controller connection, while the large terminals specify Belden 7921A shielded CAT5E to TIA 568-B.1 with an IEC 60603-7 RJ45 for Marine emission limits and the EMC Directive. Mixing the two cable rules is a commissioning failure waiting for a survey.
Organisation of the PanelView Standard range is by display size and input type: 300 Micro, 300, 550, 600, 900, 1000 and 1400, each in keypad, touch and keypad plus touch builds, with an L1 suffix for 24V DC power and L2 or L3 for stainless steel where the build allows it. Stainless is not available on the touch screen terminals.
The ControlNet module in this range carries a firmware floor that has to be quoted with the part: 2711P-RN15S or -RN15SK does not run with FactoryTalk View ME firmware at revision 3.20.04 or earlier, and every module at revision 3.07 has to be upgraded to 3.08 or later, otherwise outputs can turn on in an indeterminate state. That is a safety statement, not a compatibility note.
PanelView Plus 6 catalog numbers are built from position meaning rather than from a list: T, K or B gives touch, keypad or both, the next digit gives the display size in inches, M or C gives monochrome or colour, the two digit group gives the communication configuration, and A8 or D8 gives AC or DC input while a 9 in that position marks the extended Windows CE feature set. Reading the code is faster than searching a table, and it is the only way to be sure a substitute is equivalent.
Before ordering, confirm the terminal series letter, confirm that the part is not one of the non-replaceable builds, and confirm the cable against the connector at the controller end rather than against the protocol name.
Browse the Allen-Bradley PanelView 2711 HMI terminals category for the other models, options and spare parts that share this range.