Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1747-BSN / 1747BSN

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1829.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1747-BSN technical data PDF download 1747-BSN SLC Backup Scanner Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: SLC 500 System 1747

1747-BSN is the SLC Backup Scanner Module.

Scanner that maintains a second, standby path on a Remote I/O link so a duplicate processor can take over the link. Rockwell documents it in 1747-UM010. Rockwell lists the catalog number as discontinued on 2015-12-31, replacement category Engineering Replacement.

1747-SN SLC Remote I/O Scanner Module IN STOCK
1747-SCNR SLC ControlNet Scanner IN STOCK
1747-SDN SLC DeviceNet Scanner Module IN STOCK
1747-ASB SLC Remote I/O Adapter Module IN STOCK
1747-BSN SLC Backup Scanner Module IN STOCK
1747-ACN15 SLC ControlNet Adapter Module IN STOCK
1747-ACNR15 SLC ControlNet Adapter Module, redundant media IN STOCK
1747-DCM SLC Direct Communication Module IN STOCK
1747-KE Communication Interface Module, DH-485 to RS-232C IN STOCK
1747-KFC15 SLC Interface Module IN STOCK
1747-UIC SLC USB to DH-485 Converter IN STOCK
1747-UICC13 USB Converter Cable IN STOCK
1747-PIC SLC RS-232 to DH-485 Interface Converter IN STOCK
1747-AIC SLC Isolated Link Coupler IN STOCK
1747-DPS1 SLC Data Port Splitter IN STOCK
1747-DPS2 SLC Data Port Splitter IN STOCK

Product Specifications 1747-BSN (PDF)
 Catalog number
 1747-BSN
 Description
 SLC Backup Scanner Module
 Module type
 Backup scanner
 Channels
 Remote I/O scanner channel
 Isolation
 Not published
 Rockwell class
 Programmable logic controller
 Discontinued date
 2015-12-31
 Replacement category
 Engineering Replacement
 Replacement product
 Migrate to CMX solution (Rockwell wording)
 Publication
 1747-UM011 / 1747-IN009

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1747-UM010 (module specifications) and 1747-UM010 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1747-BSN 1747-BSN 1747-BSN 1747-BSN

What the module does

Scanner that maintains a second, standby path on a Remote I/O link so a duplicate processor can take over the link. Rockwell documents it in 1747-UM010.

It is a single-slot module for a 1746 chassis, powered from the rack backplane. Nothing in the chassis changes when it is fitted: the processor still occupies slot 0 of the first rack, and the module sits in any other slot.

Channels and electrical isolation

Rockwell prints Remote I/O scanner channel for this catalog number, and no isolation figure on the product page.

Because no isolation figure is printed for this catalog number, treat the port as unspecified and confirm with a Rockwell publication before designing a network where common-mode noise is expected.

Where it sits in the SLC 500 network architecture

SLC 500 systems reach other devices over four routes: DH-485 for peer-to-peer and programming, DH+ for PLC-5 class networks, Remote I/O for scanner and adapter racks, and the fieldbus scanners for DeviceNet and ControlNet. Each route has a distinct module pair, and mixing them up is the commonest commissioning error.

This catalog number belongs to one of those routes. The module on the other side of the link has to match it: a scanner needs an adapter, and an adapter needs a scanner. Two adapters on the same link do nothing.

Fitting and commissioning

Set the node address and the baud rate before the module goes into the rack, record both on the panel schedule, and confirm the processor sees the module in its I/O configuration. A module that is fitted but not configured in the program behaves like a missing module, not like a fault.

On a working line, the safe sequence is: power down the rack, fit the module, power up with the processor in PROG, download the configuration, then switch to RUN and watch the module status for a full production cycle.

Lifecycle status and spares

Rockwell discontinued this catalog number on 2015-12-31 with replacement category Engineering Replacement, replacement product Migrate to CMX solution (Rockwell wording).

Communication modules are the parts that fail first in an SLC 500 panel, because they carry the surge path. Keep a tested spare of the exact catalog number, and record the firmware or series letter of the working module next to it.

FAQ — 1747-BSN

What is 1747-BSN?

SLC Backup Scanner Module Scanner that maintains a second, standby path on a Remote I/O link so a duplicate processor can take over the link. Rockwell documents it in 1747-UM010.

How many channels does 1747-BSN have?

Rockwell prints Remote I/O scanner channel for this catalog number.

Is 1747-BSN still available from Rockwell?

No. Discontinued 2015-12-31, replacement category Engineering Replacement.

What is the isolation rating?

Not published.

Does 1747-BSN need a matching module at the other end of the link?

Yes. A scanner needs an adapter and an adapter needs a scanner on the same link.


Data sources. Channel counts and isolation figures come from the Rockwell product page of the catalog number; the role of each module in the network architecture is quoted from 1747-UM011. Catalog numbers whose Rockwell page has been withdrawn carry no channel or isolation figure on this page. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

The network side of the 1747 family: which end of the link each box sits on

Eight catalog numbers are the network side of the SLC family, and the useful split is not by protocol but by which end of the link they sit on: five are scanned or scan, and three answer. That is what decides whether a module goes in the processor chassis or in a remote one.

CatalogWhat it isChannel printedIsolation printedLifecycle
1747-SNRemote I/O scanner4 channels500V dc on communication circuits2024-03-31, Engineering Replacement
1747-SCNRControlNet scannerControlNet scanner channelNot published2015-12-31, Engineering Replacement
1747-SDNDeviceNet scanner, Series CDeviceNet scanner channel500V dc on communication circuits2024-03-31, Engineering Replacement
1747-ASBRemote I/O adapterRemote I/O adapter channelNot published2013-11-01, No planned RA replacement
1747-BSNBackup scannerRemote I/O scanner channelNot published2015-12-31, Engineering Replacement
1747-ACN15ControlNet adapterControlNet adapter channelNot publishedNot published, Not published
1747-ACNR15ControlNet adapter, redundant mediaTwo ControlNet media portsNot publishedNot published, Not published
1747-DCMCommunication moduleNot publishedNot publishedNot published, Not published

Where this module sits: Of the eight network numbers, 1747-BSN sits on the standby side of a Remote I/O link. Rockwell prints the channel as "Remote I/O scanner channel" and the isolation as Not published.

This map prints what each catalog number is and which side of a link it sits on. It does not print node counts, cable lengths or baud rates per module - those live in 1747-UM011 and in the scanner instruction sheets, and several of the withdrawn catalog numbers (1747-ACN15, 1747-DCM) publish no channel or isolation figure at all, so none is inferred for them.

Source: Rockwell 1747-IN009, 1747-IN007, 1747-IN019, 1747-IN062, 1747-UM011 and 1747-RM001 as recorded per catalog number, plus the Rockwell product page for each number. Every figure is quoted as printed; no value is calculated.

Related numbers