Product Details:
Payment & Shipping Terms:
|
1746-N3 is the mating connector in the Allen-Bradley SLC 500 range: 1746 SLC System, Mating Connector For Programmable Ctrlr.
It is a hardware part of the modular system rather than an I/O card, so this page records what the part does, how it has to match the rack and what Rockwell still publishes about it.
| 1746-N2 | SLC Modular Card Slot Filler | IN STOCK |
| 1746-N3 | SLC Mating Connector | IN STOCK |
| 1746-NOC | SLC 500 Spare Assembly | IN STOCK |
| 1746-NGC | SLC Integrated Circuit Assembly | IN STOCK |
| 1746-NLB | SLC LED Module Assembly | IN STOCK |
Application |
1746 SLC System, Mating Connector For Programmable Ctrlr |
Cat Num |
1746-N3 |
Brand Name |
Rockwell |
Product Type |
Mating connector |
Class |
Coaxial connectors, per the Rockwell product data |
Lifecycle |
Discontinued |
Discontinued date |
January 31, 2017 |
Replacement category |
Engineering Replacement |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN025 (module specifications) and 1746-IN025 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 1746-N3 is the mating connector for the SLC 500 rack interconnect cable. It is the half that terminates the cable end so that two chassis can be linked without the cable being wired directly into the rack.
Application: 1746 SLC System, Mating Connector For Programmable Ctrlr.
Cat Num: 1746-N3.
Brand Name: Rockwell.
Product Type: Mating connector.
Class: Coaxial connectors, per the Rockwell product data.
Lifecycle: Discontinued.
Discontinued date: January 31, 2017.
Replacement category: Engineering Replacement.
Rockwell classes the part as a coaxial connector and documents it in 1746-IN025. The connector is keyed: the coding sits outside the plug at one end of the cable and inside at the other, so the two halves only mate one way round.
A connector is the first thing to check when a two-rack system drops its link. Bent centre pins and a pushed-back shell look like a dead backplane, and the connector is the cheaper part to change first.
Spares in this family are matched on the catalog number and on the physical form of the part, not on a photograph alone, because several numbers in the N series look alike and are not interchangeable.
Rockwell lists 1746-N3 as discontinued, date January 31, 2017, replacement category Engineering Replacement.
No replacement catalog number is planned for this number, so stock in the secondary market is the supply route and a machine that depends on it should carry its own spare.
Rockwell's migration guidance for Bulletin 1746 moves I/O to Compact 5000 modules on a Logix controller; a mechanical part such as this does not migrate with the electronics.
What is 1746-N3?
1746 SLC System, Mating Connector For Programmable Ctrlr, mating connector in the SLC 500 range.
Which chassis does 1746-N3 fit?
The modular SLC 500 chassis, 1746-A4, A7, A10 and A13, and the fixed-style expansion rack where the number is listed for it.
Does 1746-N3 draw backplane current?
No. It is a mechanical or assembly part and takes no slot address.
Is 1746-N3 still available?
Rockwell lists it as discontinued, date January 31, 2017, replacement category Engineering Replacement.
Is a Rockwell publication available for 1746-N3?
Rockwell documents it under 1746-IN025.
1746-N3 belongs to the SLC 500 modular hardware range. A SLC 500 modular system is a 1746 chassis with a power supply, a processor or an I/O adapter in the left-most slot, and I/O modules in the remaining slots.
The chassis sizes published in the SLC 500 selection guide are 4, 7, 10 and 13 slots, and a maximum of three chassis can be linked in one system. Where a catalog number falls outside those published sizes, its slot count has to be confirmed against current literature before it is quoted into a bill of materials.
Module density tops out at 32 channels per module in the 1746 range, and the chassis sizes are 4, 7, 10 and 13 slots. Open slots are closed with 1746-N2 card slot fillers, which matters because an unfilled slot changes the airflow and the mechanical retention of the modules around it rather than only the appearance of the rack.
Power supply selection is a two-rail comparison, not a wattage comparison: 1746-P1 gives 2.0 A at 5V and 0.46 A at 24V, 1746-P2 gives 5.0 A and 0.96 A, 1746-P3 gives 3.6 A and 0.87 A from a 19.2 to 28.8V DC input, and 1746-P4 gives 10.0 A and 2.88 A with a 70 W total limit across all outputs. Choosing by input voltage alone and ignoring the 24V allowance is how a chassis ends up short on analog capacity.
Sizing a SLC 500 system is a fixed sequence, and it is the sequence rather than the arithmetic that stops most retrofits: count the I/O points, convert them into modules at the published channels per module, add a scanner or an adapter where the I/O sits remotely, total the 5V and 24V draws per chassis, choose the power supply that covers both totals, then choose the chassis with enough slots including fillers for the empties. Doing it in the reverse order, from a chassis that already exists, produces a system that fits mechanically and fails electrically.
Backplane budgeting is the arithmetic that decides whether a SLC 500 chassis closes: every module declares its 5V and 24V draw, the power supply declares its internal capacity for both rails, and the sum has to stay below both numbers at once. A chassis that passes on 5V and fails on 24V is the common mistake, because most digital I/O draws nothing from 24V while analog and thermocouple modules do.
Before ordering, confirm the slot count against the I/O list, confirm the 5V and 24V totals against the supply capacity rather than against the wattage, and confirm that the cable and the chassis are ordered separately, because none of these parts is included with any other.
The Allen-Bradley SLC 500 1746 I/O modules category lists the related catalog numbers, options and accessories for this range.