logo
Home ProductsAB SLC-500 Systems 1746

Allen Bradley PLC 1746-N2 / 1746N2

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1746-N2 / 1746N2

China Allen Bradley PLC 1746-N2 / 1746N2 supplier
Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier Allen Bradley PLC 1746-N2 / 1746N2 supplier

Large Image :  Allen Bradley PLC 1746-N2 / 1746N2

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1746-N2 / 1746N2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $16.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1746-N2 technical data PDF download 1746-N2 SLC Modular Card Slot Filler

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: SLC 500 spare and accessory

1746-N2 is the slot filler in the Allen-Bradley SLC 500 range: 1746 SLC System, Modular Card Slot Filler For Programmable Ctrlr.

It is a hardware part of the modular system rather than an I/O card, so this page records what the part does, how it has to match the rack and what Rockwell still publishes about it.

1746-N2 SLC Modular Card Slot Filler IN STOCK
1746-N3 SLC Mating Connector IN STOCK
1746-NOC SLC 500 Spare Assembly IN STOCK
1746-NGC SLC Integrated Circuit Assembly IN STOCK
1746-NLB SLC LED Module Assembly IN STOCK

Product Specifications 1746-N2 (PDF)
 Application
 1746 SLC System, Modular Card Slot Filler For Programmable Ctrlr
 Cat Num
 1746-N2
 Brand Name
 Rockwell
 Product Type
 Slot filler
 Function
 Fills an unused I/O slot in a modular SLC 500 chassis
 Lifecycle
 Discontinued
 Discontinued date
 September 30, 2024
 Replacement category
 No planned RA replacement

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN016 (module specifications) and 1746-IN016 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1746-N2 original product photograph 1 1746-N2 original product photograph 2 1746-N2 original product photograph 3

What 1746-N2 is

The 1746-N2 is the blank slot filler for a modular SLC 500 chassis. An unused slot left open exposes the backplane connector and leaves a gap in the card guide, so the filler is the part that keeps the chassis mechanically closed when a machine is shipped with fewer cards than slots.

Technical data

Application: 1746 SLC System, Modular Card Slot Filler For Programmable Ctrlr.

Cat Num: 1746-N2.

Brand Name: Rockwell.

Product Type: Slot filler.

Function: Fills an unused I/O slot in a modular SLC 500 chassis.

Lifecycle: Discontinued.

Discontinued date: September 30, 2024.

Replacement category: No planned RA replacement.

Fit and compatibility

It fits the modular hardware style chassis, the same rack that takes the 1746-A4, A7, A10 and A13, and it does not carry a slot address, so it can be moved between empty positions without touching the processor's I/O configuration.

How it is used in service

A filler is not a substitute for a card when a slot has to stay powered: it makes no electrical connection and draws no backplane current, which is why a chassis budget stays unchanged when one is fitted.

Spares in this family are matched on the catalog number and on the physical form of the part, not on a photograph alone, because several numbers in the N series look alike and are not interchangeable.

Lifecycle and spares position

Rockwell lists 1746-N2 as discontinued, date September 30, 2024, replacement category No planned RA replacement.

No replacement catalog number is planned for this number, so stock in the secondary market is the supply route and a machine that depends on it should carry its own spare.

Rockwell's migration guidance for Bulletin 1746 moves I/O to Compact 5000 modules on a Logix controller; a mechanical part such as this does not migrate with the electronics.

FAQ — 1746-N2

What is 1746-N2?

1746 SLC System, Modular Card Slot Filler For Programmable Ctrlr, slot filler in the SLC 500 range.

Which chassis does 1746-N2 fit?

The modular SLC 500 chassis, 1746-A4, A7, A10 and A13, and the fixed-style expansion rack where the number is listed for it.

Does 1746-N2 draw backplane current?

No. It is a mechanical or assembly part and takes no slot address.

Is 1746-N2 still available?

Rockwell lists it as discontinued, date September 30, 2024, replacement category No planned RA replacement.

Is a Rockwell publication available for 1746-N2?

Rockwell documents it under 1746-IN016.


Data sources. Technical values on this page come from Rockwell publication 1746-IN016 and the Rockwell product page for this catalog number. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1746 N2: card slot filler

1746-N2 is the card slot filler for SLC 500 modular chassis. An empty slot in a 1746 chassis is not a neutral gap: the filler closes it so that airflow through the rack stays as designed and the modules either side keep their mechanical support.

Remote I/O changes the data path, not the module: with a 1747-ASB adapter in the remote chassis, analog and thermocouple modules require block transfers, and a program written as direct I/O in a local chassis does not simply move to a remote one. The 1746-NO4I and 1746-NO4V analog outputs also accept a user-supplied 24V DC source, and that source must be 24V plus or minus 10 percent; the 1746-P1, P2, P5 and P6 user supplies do not meet that tolerance.

SLC 500 processors span 1 K to 64 K of memory and can address up to 4096 inputs and 4096 outputs, and every modular processor except the SLC 5/01 can control remotely located I/O through a scanner. That distinction is what makes a 5/01 unsuitable as the head of a distributed system regardless of its I/O count.

Sizing a SLC 500 system is a fixed sequence, and it is the sequence rather than the arithmetic that stops most retrofits: count the I/O points, convert them into modules at the published channels per module, add a scanner or an adapter where the I/O sits remotely, total the 5V and 24V draws per chassis, choose the power supply that covers both totals, then choose the chassis with enough slots including fillers for the empties. Doing it in the reverse order, from a chassis that already exists, produces a system that fits mechanically and fails electrically.

The processor or the I/O adapter occupies the left-most slot of a 1746 chassis, and the power supply is a separate unit mounted on the left end of the chassis rather than a module inside it. That is why a spare chassis is not a spare system: chassis, power supply and processor are three catalog numbers, and the interconnect cable is a fourth.

Before ordering, confirm the slot count against the I/O list, confirm the 5V and 24V totals against the supply capacity rather than against the wattage, and confirm that the cable and the chassis are ordered separately, because none of these parts is included with any other.

Other catalog numbers and accessories for the same range are collected in the Allen-Bradley SLC 500 1746 I/O modules category.