Product Details:
Payment & Shipping Terms:
|
1746-IM4 is the 4 Point 240V AC Input Module in the Allen-Bradley SLC 500 range: 1746 SLC System, 4 ch-AC Input Module For Programmable Controller.
It sits in an SLC 500 chassis slot and exchanges data with the processor through the backplane image table; the points, voltage category and backplane current below are what decide whether it fits the slot and the power budget.
| 1746-IA4 | 4 Point AC Input Module | IN STOCK |
| 1746-IA8 | 8 Point AC Input Module | IN STOCK |
| 1746-IM4 | 4 Point 240V AC Input Module | IN STOCK |
| 1746-IM8 | 8 Point 240V AC Input Module | IN STOCK |
| 1746-IM16 | 16 Point 240V AC Input Module | IN STOCK |
| 1746-IN16 | 16 Point 24V AC Input Module | IN STOCK |
Application |
1746 SLC System, 4 ch-AC Input Module For Programmable Controller |
Cat Num |
1746-IM4 |
Brand Name |
Rockwell |
Product Type |
4 Point 240V AC Input Module |
Points |
4 inputs |
Points per common |
4 |
Voltage category |
200/240V AC signal input |
Operating voltage |
170...265V AC @ 47...63 Hz |
Backplane current, 5V DC |
0.035 A |
Backplane current, 24V DC |
0.0 A |
Signal delay, max |
On = 35 ms, Off = 45 ms |
Isolation |
1500V, electro-optical to control logic |
Lifecycle |
Discontinued |
Discontinued date |
December 31, 2022 |
Replacement category |
Engineering Replacement |
1746-IM4 (SLC 500 4-channel 240 V AC input module): 4 inputs on 4 points per common, 200/240 V AC category, 170...265 V AC at 47...63 Hz, nominal 12 mA at 240 V AC and 35 mA from the 5 V backplane. Off-state voltage 50 V AC maximum; signal delay 35 ms on / 45 ms off. Heat dissipation 0.175 W minimum, 1.60 W maximum (0.350 W per point).
It is the card for 220/240 V AC control circuits that are already pulled from a European panel supply - the higher off-state threshold (50 V AC) is what keeps leakage through a shared neutral from reading as a false ON. Sources: Rockwell publications 1747-SG001 (SLC 500 digital I/O specifications and module descriptions) and 1747-UM011 (power supply worksheet and heat dissipation).
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN027 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Official Rockwell description: 1746 SLC System, 4 ch-AC Input Module For Programmable Controller.
4 Point 240V AC Input Module, with 4 inputs and 4 per common terminal.
Application: 1746 SLC System, 4 ch-AC Input Module For Programmable Controller.
Cat Num: 1746-IM4.
Brand Name: Rockwell.
Product Type: 4 Point 240V AC Input Module.
Points: 4 inputs.
Points per common: 4.
Voltage category: 200/240V AC signal input.
Operating voltage: 170...265V AC @ 47...63 Hz.
Backplane current, 5V DC: 0.035 A.
Backplane current, 24V DC: 0.0 A.
Signal delay, max: On = 35 ms, Off = 45 ms.
Isolation: 1500V, electro-optical to control logic.
Lifecycle: Discontinued.
Discontinued date: December 31, 2022.
Replacement category: Engineering Replacement.
An AC input circuit on the SLC 500 carries a 47...63 Hz filter and an inrush limit, so the field device has to suit the published inrush rather than only the voltage.
Off-state voltage and off-state current are printed for each family because a leaking sensor or a shared neutral can hold an AC input on after the device has dropped out.
Signal delay is 35 ms ON and 45 ms OFF at 60 Hz for the 120V and 240V families, which is normal for a filtered AC input and has to be considered in a short machine cycle.
Rockwell lists 1746-IM4 as Discontinued, with the discontinued date December 31, 2022 and the replacement category Engineering Replacement.
No replacement catalog number is printed on the Rockwell page, so the route is an engineering substitution rather than a direct part-for-part swap.
Rockwell's own migration guidance for Bulletin 1746 I/O points to the Compact 5000 I/O platform with a Logix controller; a machine that stays on SLC 500 is served from the secondary market.
The enclosure, the terminal armature and the address assignment are unchanged when a card is replaced by the same catalog number, which is why the original number keeps a value after the end of sale.
A modular SLC 500 chassis reserves slot 0 for the processor or the adapter, so this card goes in any other I/O slot; a fixed controller chassis has a published power limit instead of a slot rule.
The backplane current above is added to the draw of every other card in the chassis and compared with the chassis supply before a card is added, which is the check that prevents an intermittent chassis fault after a retrofit.
Electro-optical isolation between the field terminals and the control logic is 1500V, and the operating range of the whole family is 0...60 °C with 5...95% noncondensing humidity and NEMA ICS 2-230 noise immunity.
The card in red in the table at the top is the one on this page.
What is 1746-IM4?
1746 SLC System, 4 ch-AC Input Module For Programmable Controller. 4 Point 240V AC Input Module.
How many points does 1746-IM4 have?
4 inputs, 4 per common.
What voltage does 1746-IM4 work at?
200/240V AC signal input, operating range 170...265V AC @ 47...63 Hz.
Is 1746-IM4 still available?
Rockwell lists it as Discontinued with the discontinued date December 31, 2022, replacement category Engineering Replacement.
What has to be checked before fitting 1746-IM4?
The backplane current against the chassis supply, the sinking or sourcing convention of the field devices, and the terminal block, which is removable and often missing on a used card.
Browse the Allen-Bradley SLC 500 1746 I/O modules category for the other models, options and spare parts that share this range.