Product Details:
Payment & Shipping Terms:
|
1746-A2 is the 2-slot chassis of the Allen-Bradley SLC 500 modular system: 2-SLOT EXPAN. CHAS FOR FIXED Hdw Style.
The chassis is the part that fixes the machine's I/O count. Every card, the processor and the power supply are sized against the slots and the backplane rails this rack provides.
| 1746-A2 | 2-Slot Expansion Chassis | IN STOCK |
| 1746-A4 | SLC 4 Slots Chassis | IN STOCK |
| 1746-A7 | SLC 7 Slots Chassis | IN STOCK |
| 1746-A10 | SLC 10 Slots Chassis | IN STOCK |
| 1746-A13 | SLC 13 Slots Chassis | IN STOCK |
Application |
2-SLOT EXPAN. CHAS FOR FIXED Hdw Style |
Cat Num |
1746-A2 |
Brand Name |
Rockwell |
Product Type |
SLC 500 2-slot chassis |
Number of slots |
2 |
Chassis |
2-slot chassis, modular hardware style |
Chassis type |
Expansion chassis for the fixed hardware style controller |
Temperature rating |
0...60 °C (32...140 °F) |
Lifecycle |
Discontinued |
Discontinued date |
October 7, 2016 |
Replacement category |
Functional Replacement |
Replacement product |
1746-A4 (Rockwell lists the upgrade to the 4-slot chassis) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN016 (module specifications) and 1746-IN016 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Rockwell description: 2-SLOT EXPAN. CHAS FOR FIXED Hdw Style.
It is a 2-slot chassis in the modular hardware style, with a card guide per slot, one backplane connector per slot and a mounting foot at each end.
Application: 2-SLOT EXPAN. CHAS FOR FIXED Hdw Style.
Cat Num: 1746-A2.
Brand Name: Rockwell.
Product Type: SLC 500 2-slot chassis.
Number of slots: 2.
Chassis: 2-slot chassis, modular hardware style.
Chassis type: Expansion chassis for the fixed hardware style controller.
Temperature rating: 0...60 °C (32...140 °F).
Lifecycle: Discontinued.
Discontinued date: October 7, 2016.
Replacement category: Functional Replacement.
Replacement product: 1746-A4 (Rockwell lists the upgrade to the 4-slot chassis).
Slot 0 is reserved for the processor or for a communication adapter; the remaining 1 slots take I/O and specialty modules. The power supply mounts at the left end of the rack and is not a slot.
Rockwell documents the modular SLC 500 system as connecting up to three chassis with 30 I/O modules to a single controller or communication adapter, so a 2-slot rack is one segment of that budget, not the whole limit.
The 1746-A2 is the exception: it is an expansion chassis for the fixed hardware style controller and carries no processor slot, so it only extends the I/O count of a fixed-style unit.
The rack runs at 0...60 °C ambient and cools by convection, so the enclosure has to let air move past the cards. The minimum enclosure figures Rockwell prints are the space the rack and its terminal blocks need, not a clearance allowance for wiring.
Rockwell does not print a separate minimum enclosure size for this chassis on the product data; the figure for the 4-slot rack is 17.1 x 17.7 x 14.5 cm, and the depth carries across the family.
Field wiring lands on the removable terminal blocks at the front of each card, so the panel needs working room in front of the rack as well as above and below it.
Rockwell lists 1746-A2 as discontinued, date October 7, 2016, replacement category Functional Replacement.
1746-A4 (Rockwell lists the upgrade to the 4-slot chassis).
Rockwell's migration guidance for Bulletin 1746 routes I/O to Compact 5000 modules on a Logix controller; a chassis is the part that cannot be carried across, because the new I/O does not use this backplane.
What is 1746-A2?
2-SLOT EXPAN. CHAS FOR FIXED Hdw Style. 2-slot chassis, modular hardware style.
How many slots does 1746-A2 have?
2 slots, of which slot 0 is reserved for the processor or an adapter.
What is the ambient temperature rating of 1746-A2?
0...60 °C (32...140 °F), convection cooled.
Is 1746-A2 still available?
Rockwell lists it as discontinued, date October 7, 2016, replacement category Functional Replacement.
How many chassis can one SLC 500 controller drive?
Up to three chassis with 30 I/O modules in total, per Rockwell's SLC I/O system description.
1746-A2 belongs to the SLC 500 modular hardware range. A SLC 500 modular system is a 1746 chassis with a power supply, a processor or an I/O adapter in the left-most slot, and I/O modules in the remaining slots.
The chassis sizes published in the SLC 500 selection guide are 4, 7, 10 and 13 slots, and a maximum of three chassis can be linked in one system. Where a catalog number falls outside those published sizes, its slot count has to be confirmed against current literature before it is quoted into a bill of materials.
Module density tops out at 32 channels per module in the 1746 range, and the chassis sizes are 4, 7, 10 and 13 slots. Open slots are closed with 1746-N2 card slot fillers, which matters because an unfilled slot changes the airflow and the mechanical retention of the modules around it rather than only the appearance of the rack.
SLC 500 processors span 1 K to 64 K of memory and can address up to 4096 inputs and 4096 outputs, and every modular processor except the SLC 5/01 can control remotely located I/O through a scanner. That distinction is what makes a 5/01 unsuitable as the head of a distributed system regardless of its I/O count.
Sizing a SLC 500 system is a fixed sequence, and it is the sequence rather than the arithmetic that stops most retrofits: count the I/O points, convert them into modules at the published channels per module, add a scanner or an adapter where the I/O sits remotely, total the 5V and 24V draws per chassis, choose the power supply that covers both totals, then choose the chassis with enough slots including fillers for the empties. Doing it in the reverse order, from a chassis that already exists, produces a system that fits mechanically and fails electrically.
Backplane budgeting is the arithmetic that decides whether a SLC 500 chassis closes: every module declares its 5V and 24V draw, the power supply declares its internal capacity for both rails, and the sum has to stay below both numbers at once. A chassis that passes on 5V and fails on 24V is the common mistake, because most digital I/O draws nothing from 24V while analog and thermocouple modules do.
Before ordering, confirm the slot count against the I/O list, confirm the 5V and 24V totals against the supply capacity rather than against the wattage, and confirm that the cable and the chassis are ordered separately, because none of these parts is included with any other.
Related models, options and spare parts for this range are listed in the Allen-Bradley SLC 500 1746 I/O modules category.