logo
Home ProductsAB SLC-500 Systems 1746

Allen Bradley PLC 1746-OAP12 / 1746OAP12

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1746-OAP12 / 1746OAP12

China Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier
Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier Allen Bradley PLC 1746-OAP12 / 1746OAP12 supplier

Large Image :  Allen Bradley PLC 1746-OAP12 / 1746OAP12

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1746-OAP12 / 1746OAP12

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $426.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1746-OAP12 technical data PDF download 1746-OAP12 High Current Triac Output Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: SLC 500 triac output module

1746-OAP12 is the High Current Triac Output Module in the Allen-Bradley SLC 500 range: 1746 SLC System, 12 ch-Triac Output Module, high current.

It sits in an SLC 500 chassis slot and exchanges data with the processor through the backplane image table; the points, voltage category and backplane current below are what decide whether it fits the slot and the power budget.

1746-OA8 8 Point Triac Output Module IN STOCK
1746-OA16 16 Point Triac Output Module IN STOCK
1746-OAP12 High Current Triac Output Module IN STOCK

Product Specifications 1746-OAP12 (PDF)
 Application
 1746 SLC System, 12 ch-Triac Output Module, high current
 Cat Num
 1746-OAP12
 Brand Name
 Rockwell
 Product Type
 High Current Triac Output Module
 Points
 12 outputs
 Points per common
 6
 Voltage category
 120/240V AC signal output
 Operating voltage
 85...265V AC @ 47...63 Hz
 Backplane current, 5V DC
 0.370 A
 Backplane current, 24V DC
 0.0 A
 Signal delay, max
 On = 1 ms, Off = 11.0 ms
 Isolation
 1500V, electro-optical to control logic
 Lifecycle
 Discontinued
 Discontinued date
 December 31, 2015
 Replacement category
 Engineering Replacement

1746-OAP12 (SLC 500 12-channel 120/240 V AC protected triac output module): 12 protected triac outputs, 120/240 V AC category, fused commons with a blown-fuse LED on the front of the module, 370 mA from the 5 V backplane. Heat dissipation 1.850 W minimum, 10.85 W maximum (1.000 W per point).

The blown-fuse LED is the practical difference against 1746-OA16: a dead output is diagnosed from the door of the enclosure, and a replacement fuse holder is available as 1746-R17. Twelve points instead of sixteen means the card is chosen when the AC load count is already known. Sources: Rockwell publications 1747-SG001 (SLC 500 digital I/O specifications and module descriptions) and 1747-UM011 (power supply worksheet and heat dissipation).

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN027 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1746-OAP12 original product photograph 1 1746-OAP12 original product photograph 2 1746-OAP12 original product photograph 3

What 1746-OAP12 is

Official Rockwell description: 1746 SLC System, 12 ch-Triac Output Module, high current.

High Current Triac Output Module, with 12 outputs and 6 per common terminal.

Technical data

Application: 1746 SLC System, 12 ch-Triac Output Module, high current.

Cat Num: 1746-OAP12.

Brand Name: Rockwell.

Product Type: High Current Triac Output Module.

Points: 12 outputs.

Points per common: 6.

Voltage category: 120/240V AC signal output.

Operating voltage: 85...265V AC @ 47...63 Hz.

Backplane current, 5V DC: 0.370 A.

Backplane current, 24V DC: 0.0 A.

Signal delay, max: On = 1 ms, Off = 11.0 ms.

Isolation: 1500V, electro-optical to control logic.

Lifecycle: Discontinued.

Discontinued date: December 31, 2015.

Replacement category: Engineering Replacement.

Wiring and commissioning notes

A triac output switches at the AC zero cross, so the published OFF delay is a line-frequency figure and not a logic delay.

A minimum load current is needed to hold the triac on; below it the output can stay off or chatter, and a bleed resistor across the load is the usual fix.

Continuous current per point is 1.0 A at 30 °C and 0.50 A at 60 °C on the 8-point card, so a panel that runs warm has to be derated before the load is chosen.

Lifecycle and migration route

Rockwell lists 1746-OAP12 as Discontinued, with the discontinued date December 31, 2015 and the replacement category Engineering Replacement.

No replacement catalog number is printed on the Rockwell page, so the route is an engineering substitution rather than a direct part-for-part swap.

Rockwell's own migration guidance for Bulletin 1746 I/O points to the Compact 5000 I/O platform with a Logix controller; a machine that stays on SLC 500 is served from the secondary market.

The enclosure, the terminal armature and the address assignment are unchanged when a card is replaced by the same catalog number, which is why the original number keeps a value after the end of sale.

Power budget and slot rules

A modular SLC 500 chassis reserves slot 0 for the processor or the adapter, so this card goes in any other I/O slot; a fixed controller chassis has a published power limit instead of a slot rule.

The backplane current above is added to the draw of every other card in the chassis and compared with the chassis supply before a card is added, which is the check that prevents an intermittent chassis fault after a retrofit.

Electro-optical isolation between the field terminals and the control logic is 1500V, and the operating range of the whole family is 0...60 °C with 5...95% noncondensing humidity and NEMA ICS 2-230 noise immunity.

Related cards in this family

  • 1746-OA8 — 8 Point Triac Output Module
  • 1746-OA16 — 16 Point Triac Output Module
  • 1746-OAP12 — High Current Triac Output Module

The card in red in the table at the top is the one on this page.

FAQ — 1746-OAP12

What is 1746-OAP12?

1746 SLC System, 12 ch-Triac Output Module, high current. High Current Triac Output Module.

How many points does 1746-OAP12 have?

12 outputs, 6 per common.

What voltage does 1746-OAP12 work at?

120/240V AC signal output, operating range 85...265V AC @ 47...63 Hz.

Is 1746-OAP12 still available?

Rockwell lists it as Discontinued with the discontinued date December 31, 2015, replacement category Engineering Replacement.

What has to be checked before fitting 1746-OAP12?

The backplane current against the chassis supply, the sinking or sourcing convention of the field devices, and the terminal block, which is removable and often missing on a used card.


Data sources. Technical values on this page come from Rockwell publication 1746-IN027 (SLC 500 Digital I/O Modules) and the Rockwell product page for this catalog number. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

The AC output group on the 1746 backplane: points against printed current

Every 1746 digital module is one slot wide, so slot count is never the constraint in an SLC rack - the 5 V and 24 V backplane currents are. This table is the printed current for each module in the same functional group, taken from the 1746-IN027 specification rows, so the budget can be added up before the rack is ordered instead of after it browns out.

CatalogPointsSignal5 V backplane24 V backplaneSignal delay
1746-OA88 outputs120/240V AC signal output0.185 A0.0 AOn = 1 ms, Off = 11.0 ms
1746-OA1616 outputs120/240V AC signal output0.370 A0.0 AOn = 1 ms, Off = 11.0 ms
1746-OAP1212 outputs120/240V AC signal output0.370 A0.0 AOn = 1 ms, Off = 11.0 ms

Where this module sits: Read the backplane column before the point count: 1746-OAP12 takes 0.370 A at 5 V and 0.0 A at 24 V. Added up, on the 5 A 1746-P2 even the tighter rail (the 5 V one) carries 13 of them, more than the thirteen slots of the longest 1746 chassis, so slot count and not current decides.

Two things this block does not answer. It gives the module current, not the surge a rack sees at power-up, which is printed separately as inrush for the supply and not per module. And it says nothing about the 24 V field supply drawn by the loads themselves - the 24 V backplane figure is what the module takes from the rack, not what the sensors and coils take from the field supply.

Source: Rockwell 1746-IN027 digital I/O specification rows, 1746-IN008 and 1746-UM007 analog rows, 1746-IN016/IN004 chassis and supply rows. Backplane currents are quoted as printed; only the "how many fit" divisions are arithmetic, and they are integer divisions of the printed capacity.