Product Details:
Payment & Shipping Terms:
|
1746-NO8V is the 8 Point Analog Voltage Output Module in the Allen-Bradley SLC 500 range: 1746 SLC System, 8 channel Analog Voltage Output For SLC 500.
It occupies one I/O slot, takes both backplane rails, and is configured channel by channel from the processor; the ranges, resolution and filter settings below are the ones a project engineer needs before the loop is designed.
| 1746-NO8V | 8 Point Analog Voltage Output Module | IN STOCK |
Application |
1746 SLC System, 8 channel Analog Voltage Output For SLC 500 |
Cat Num |
1746-NO8V |
Brand Name |
Rockwell |
Product Type |
8 Point Analog Voltage Output Module |
Channels |
8 voltage outputs |
Input range |
- |
Output range |
Voltage output, range configured per channel in software |
Resolution |
16-bit |
Backplane current, 5V DC |
120 mA |
Backplane current, 24V DC |
160 mA |
Update time / filtering |
Software configured, no DIP switches |
Isolation |
500V dc |
Lifecycle |
Discontinued |
Discontinued date |
September 30, 2024 |
Replacement category |
Engineering Replacement |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-UM026 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Official Rockwell description: 1746 SLC System, 8 channel Analog Voltage Output For SLC 500.
8 Point Analog Voltage Output Module with 8 voltage outputs.
Application: 1746 SLC System, 8 channel Analog Voltage Output For SLC 500.
Cat Num: 1746-NO8V.
Brand Name: Rockwell.
Product Type: 8 Point Analog Voltage Output Module.
Channels: 8 voltage outputs.
Input range: -.
Output range: Voltage output, range configured per channel in software.
Resolution: 16-bit.
Backplane current, 5V DC: 120 mA.
Backplane current, 24V DC: 160 mA.
Update time / filtering: Software configured, no DIP switches.
Isolation: 500V dc.
Lifecycle: Discontinued.
Discontinued date: September 30, 2024.
Replacement category: Engineering Replacement.
A voltage output drives ±10V dc into 1 kΩ or higher and limits at 10 mA, which is a drive or analog meter input rather than a loop.
Range and data format are set per channel in software; the jumper J4 selects backplane or external 24V dc supply for the analog circuitry.
A long cable to a drive is an aerial for the chopper in the drive's front end, so a shielded twisted pair terminated at the module is the only wiring that keeps the 16-bit resolution usable.
Rockwell lists 1746-NO8V as Discontinued, discontinued date September 30, 2024, replacement category Engineering Replacement.
No replacement catalog number is printed on the Rockwell page, so the route is an engineering substitution with a re-ranged analogue front end, not a part-for-part swap.
Rockwell's migration guidance for Bulletin 1746 routes analog points to Compact 5000 analog modules with a Logix controller; machines that stay on SLC 500 are supported from the secondary market.
The terminal block, the slot address and the module ID code stay the same when a card is replaced by the same catalog number, which is why the original number still has a place in a maintenance spares list after the end of sale.
A modular SLC 500 reserves slot 0 for the processor or the adapter, so this module goes in any other I/O slot; the current drawn from 5V dc and 24V dc both count against the chassis supply.
The analog front end is factory calibrated and, on the newer cards, autocalibrates at power-up and on channel enable, so an accuracy figure quoted at 25 °C is what the card delivers without a field trim.
Isolation is 500V dc between the field terminals and the backplane; that figure, not the channel count, is what decides whether a card can sit next to a drive with a noisy earth.
The card in red in the catalogue table at the top of this page is the one described here.
What is 1746-NO8V?
1746 SLC System, 8 channel Analog Voltage Output For SLC 500. 8 Point Analog Voltage Output Module.
How many channels does 1746-NO8V have?
8 voltage outputs.
What ranges does 1746-NO8V accept?
Inputs: -. Outputs: Voltage output, range configured per channel in software.
How much backplane current does 1746-NO8V draw?
120 mA at 5V dc and 160 mA at 24V dc.
Is 1746-NO8V still available?
Rockwell lists it as Discontinued, discontinued date September 30, 2024, replacement category Engineering Replacement.
1746-NO8V is a 8-channel analog voltage output module for the SLC 500 modular chassis. It occupies one slot to the right of the processor, draws its backplane current from the chassis power supply, and presents its field wiring on a removable terminal block.
| Attribute | Value |
| Catalog number | 1746-NO8V |
| Module type | 8-channel analog voltage output module |
| Outputs | 8 |
| Output type | Voltage |
| Output range | +/-10.25V DC |
| Backplane current @ 5V | 120 mA |
| Backplane current @ 24V | 160 mA |
| Backplane power consumption | 5.6 W |
| Thermal dissipation, max | 4.44 W |
| Isolation voltage | Tested at 500V DC |
| Resolution | 16-bit, 320 uV per count |
| Output coding | -32,768...+32,767 |
The 24V draw of 160 mA is what separates this module from a digital output in the chassis budget: it is a real load on the 24V rail, and the optional user 24V supply for the analog outputs must be an NEC Class 2 source. The 320 uV per count resolution and the 4.44 W dissipation are the two numbers that matter in a loop: the first sets the smallest resolvable step, the second sets how much the module heats the enclosure.
Module density tops out at 32 channels per module in the 1746 range, and the chassis sizes are 4, 7, 10 and 13 slots. Open slots are closed with 1746-N2 card slot fillers, which matters because an unfilled slot changes the airflow and the mechanical retention of the modules around it rather than only the appearance of the rack.
Heat is part of the same calculation as current: the selection guide carries a heat dissipation figure per module, and the chassis total is the sum of those figures. A rack that is electrically legal and thermally packed still derates in a closed cabinet, which is why the procedure in the guide sums watts slot by slot instead of estimating from the 5V current.
Sizing a SLC 500 system is a fixed sequence, and it is the sequence rather than the arithmetic that stops most retrofits: count the I/O points, convert them into modules at the published channels per module, add a scanner or an adapter where the I/O sits remotely, total the 5V and 24V draws per chassis, choose the power supply that covers both totals, then choose the chassis with enough slots including fillers for the empties. Doing it in the reverse order, from a chassis that already exists, produces a system that fits mechanically and fails electrically.
Backplane budgeting is the arithmetic that decides whether a SLC 500 chassis closes: every module declares its 5V and 24V draw, the power supply declares its internal capacity for both rails, and the sum has to stay below both numbers at once. A chassis that passes on 5V and fails on 24V is the common mistake, because most digital I/O draws nothing from 24V while analog and thermocouple modules do.
Before ordering, confirm the slot count against the I/O list, confirm the 5V and 24V totals against the supply capacity rather than against the wattage, and confirm that the cable and the chassis are ordered separately, because none of these parts is included with any other.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley SLC 500 1746 I/O modules category.