Product Details:
Payment & Shipping Terms:
|
1746-C16 is a rack interconnect cable for the SLC 500: 50-Inch Rack Interconnect Cable.
It links two chassis so that the processor sees the I/O in the second rack as part of the same system, which is how an SLC 500 grows past the slots of a single chassis.
| 1746-C7 | SLC 6 inch Interconnect Cable | IN STOCK |
| 1746-C9 | SLC 36 inch Interconnect Cable | IN STOCK |
| 1746-C16 | SLC 50 inch Interconnect Cable | IN STOCK |
Application |
1746 SLC System, 50-Inch Rack Interconnect Cable |
Cat Num |
1746-C16 |
Brand Name |
Rockwell |
Product Type |
SLC 500 rack interconnect cable |
Cable length |
1270.0 mm (50 in.) |
Temperature rating |
0...60 °C (32...140 °F) |
Lifecycle |
Discontinued |
Discontinued date |
December 31, 2022 |
Replacement category |
No planned RA replacement |
1746-C16 (chassis interconnect cable): 1.27 m (50 in) ribbon cable that carries the backplane between SLC 500 modular chassis. It links chassis from 0.914 m (36 in) up to 1.27 m (50 in) apart.
Layout consequence: plan the same chassis spacing rules as 1746-C9 apply at the far end. Mechanically, it is the longest chassis interconnect cable Rockwell recommends, and it also carries the rigid shrink-wrap ends that need 101.6 mm (4 in) of clearance. The cable is a fixed-length part - spacing is set by the cable, not adjusted at site - so the enclosure layout has to be decided before the chassis are drilled. Source: Rockwell publication 1747-UM011, chassis interconnect cable description and the recommended mounting spacing figures.
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN029 (module specifications) and 1746-IN029 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Rockwell description: 1746 SLC System, 50-Inch Rack Interconnect Cable.
The cable is 1270.0 mm (50 in.) long and carries the rack-to-rack link only. I/O wiring stays in the terminal blocks of each card.
Application: 1746 SLC System, 50-Inch Rack Interconnect Cable.
Cat Num: 1746-C16.
Brand Name: Rockwell.
Product Type: SLC 500 rack interconnect cable.
Cable length: 1270.0 mm (50 in.).
Temperature rating: 0...60 °C (32...140 °F).
Lifecycle: Discontinued.
Discontinued date: December 31, 2022.
Replacement category: No planned RA replacement.
Rockwell lists exactly three rack interconnect cables: 1746-C7 at 152.44 mm (6 in.), 1746-C9 at 914.4 mm (36 in.) and 1746-C16 at 1270.0 mm (50 in.). There is no longer option in the family.
1746-IN029 warns that longer cables can degrade the data link between the racks and may compromise safe operation, so the cable is not a part to extend with a field splice or a longer substitute.
Choose the shortest cable that reaches: the 6-inch cable is the one for two racks bolted side by side and the 36-inch or 50-inch cable is for a rack above another.
The connector is keyed. The coding sits on the outside of the plug at one end of the cable and on the inside at the other, so the cable only mates one way round; forcing it damages the shell.
The cable is held by the latch tabs on the socket, which are pressed outward to release it. Rockwell requires the cable to be secured against shock and vibration once fitted.
The 50-inch cable is the one Rockwell specifies when two 1746-A13 racks are mounted one above the other with 1746-P4 power supplies.
Rockwell lists 1746-C16 as discontinued, date December 31, 2022, replacement category No planned RA replacement.
Cables are the first part lost when a machine is dismantled, and they are not interchangeable between lengths, so the catalog number on the connector shell is the thing to record before a rack is split.
A two-rack system that loses its second rack is usually a cable or a connector, in that order, before it is a backplane fault.
What is 1746-C16?
1746 SLC System, 50-Inch Rack Interconnect Cable, 1270.0 mm (50 in.) long.
How long is 1746-C16?
1270.0 mm (50 in.).
Which SLC 500 racks does 1746-C16 connect?
Two modular chassis: the cable carries the rack-to-rack link and the I/O stays on the cards.
Can a longer cable be substituted for 1746-C16?
No. Rockwell lists only the 6, 36 and 50 inch cables and warns that longer cables can degrade the link.
Is 1746-C16 still available?
Rockwell lists it as discontinued, date December 31, 2022, replacement category No planned RA replacement.
1746-C16 is a chassis interconnect cable for chassis 0.914 m (36 in.) to 1.27 m (50 in.) apart. SLC 500 modular systems can link up to three chassis, and the interconnect cable is selected by the distance between the enclosures, not by the number of slots in either chassis.
Module density tops out at 32 channels per module in the 1746 range, and the chassis sizes are 4, 7, 10 and 13 slots. Open slots are closed with 1746-N2 card slot fillers, which matters because an unfilled slot changes the airflow and the mechanical retention of the modules around it rather than only the appearance of the rack.
Heat is part of the same calculation as current: the selection guide carries a heat dissipation figure per module, and the chassis total is the sum of those figures. A rack that is electrically legal and thermally packed still derates in a closed cabinet, which is why the procedure in the guide sums watts slot by slot instead of estimating from the 5V current.
Sizing a SLC 500 system is a fixed sequence, and it is the sequence rather than the arithmetic that stops most retrofits: count the I/O points, convert them into modules at the published channels per module, add a scanner or an adapter where the I/O sits remotely, total the 5V and 24V draws per chassis, choose the power supply that covers both totals, then choose the chassis with enough slots including fillers for the empties. Doing it in the reverse order, from a chassis that already exists, produces a system that fits mechanically and fails electrically.
Backplane budgeting is the arithmetic that decides whether a SLC 500 chassis closes: every module declares its 5V and 24V draw, the power supply declares its internal capacity for both rails, and the sum has to stay below both numbers at once. A chassis that passes on 5V and fails on 24V is the common mistake, because most digital I/O draws nothing from 24V while analog and thermocouple modules do.
Before ordering, confirm the slot count against the I/O list, confirm the 5V and 24V totals against the supply capacity rather than against the wattage, and confirm that the cable and the chassis are ordered separately, because none of these parts is included with any other.
The Allen-Bradley SLC 500 1746 I/O modules category lists the related catalog numbers, options and accessories for this range.