1746-BTM is the Barrel temperature control module for the Allen-Bradley SLC 500: Barrel Temperature Control Module for injection molding and extrusion.
It is a specialty module, so the values below are the ones Rockwell publishes for this catalog number, and anything the publication does not print is marked not published.
| 1746-HSCE | SLC 1 Channel High Speed Counter Module | IN STOCK |
| 1746-HSCE2 | SLC 4 Channel High Speed Counter Module | IN STOCK |
| 1746-HSTP1 | SLC 1 Axis Stepper Module | IN STOCK |
| 1746-BTM | SLC Barrel Temperature Control Module | IN STOCK |
| 1746-BAS-T | SLC High Speed BASIC Language Module | IN STOCK |
| 1746-INT4 | SLC 4 Channel Isolated Thermocouple Module | IN STOCK |
| 1746-HCA | IMC 110 to Terminal Panel Cable | IN STOCK |
| 1746-HT | IMC 110 Termination Panel | IN STOCK |
Application |
Barrel Temperature Control Module for injection molding and extrusion |
Cat Num |
1746-BTM |
Brand Name |
Rockwell |
Product Type |
Barrel temperature control module |
Number of inputs |
4 analog thermocouple (TC) inputs |
Control loops |
maximum of 4 PID loops |
Resolution |
16-bit |
Chassis position |
local I/O chassis only, not a remote rack |
Lifecycle |
Discontinued |
Discontinued date |
Not published (Rockwell product page retired; see 1746-UM010) |
Replacement category |
Not published |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-UM010 (module specifications) and 1746-UM010 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 1746-BTM is the barrel temperature control module: four thermocouple inputs and up to four PID loops that run on the module, not in the SLC ladder.
Application: Barrel Temperature Control Module for injection molding and extrusion.
Cat Num: 1746-BTM.
Brand Name: Rockwell.
Product Type: Barrel temperature control module.
Number of inputs: 4 analog thermocouple (TC) inputs.
Control loops: maximum of 4 PID loops.
Resolution: 16-bit.
Chassis position: local I/O chassis only, not a remote rack.
Lifecycle: Discontinued.
Discontinued date: Not published (Rockwell product page retired; see 1746-UM010).
Replacement category: Not published.
Each input is the process variable of its own loop. The control variable leaves the module either as an analog value or as a time-proportioned output that the ladder sends on to an output card, which is how a heater bank with a contactor is driven without an analog output card.
The module also runs a tuning-assisted-process algorithm per loop, so a barrel zone can be tuned without a manual trial-and-error routine. Rockwell restricts the module to barrel temperature control of injection moulding and extrusion and states that other applications are not supported.
It belongs in the local chassis of a moulding machine. Rockwell's manual is explicit that the module is not a general-purpose loop controller, which matters when a project tries to reuse it for a furnace or an oven zone.
A slot-zero rule applies across the family: the module goes in any I/O slot except the processor slot, and its address follows the slot number.
Rockwell lists 1746-BTM as discontinued, date Not published (Rockwell product page retired; see 1746-UM010), replacement category Not published.
No replacement catalog number is printed on the Rockwell page for this number, so the route is an engineering substitution with the function re-implemented on a Logix platform.
Rockwell documents the module in 1746-UM010; that publication, not a distributor page, is the source for the values above.
What is 1746-BTM?
Barrel Temperature Control Module for injection molding and extrusion. Barrel temperature control module.
How many channels does 1746-BTM have?
See the technical data table above.
Which slot does 1746-BTM go in?
Any I/O slot except slot 0, which is reserved for the processor.
What isolation does 1746-BTM provide?
Not published for this catalog number.
Is 1746-BTM still available?
Rockwell lists it as discontinued, date Not published (Rockwell product page retired; see 1746-UM010), replacement category Not published.
1746-BTM is a barrel temperature module for the SLC 500 modular chassis. It occupies one slot to the right of the processor, draws its backplane current from the chassis power supply, and presents its field wiring on a removable terminal block.
| Attribute | Value |
| Catalog number | 1746-BTM |
| Module type | barrel temperature module |
| Backplane current @ 5V | 110 mA |
| Backplane current @ 24V | 85 mA |
| Application | Barrel and melt temperature measurement on injection moulding machines |
A barrel temperature module is a dedicated function card rather than a general analog input: it reads the thermocouples mounted on the machine barrel and presents them to the processor as a group, which is why its channel count and its scan behaviour are specified by the application rather than by a generic analog specification sheet.
Module density tops out at 32 channels per module in the 1746 range, and the chassis sizes are 4, 7, 10 and 13 slots. Open slots are closed with 1746-N2 card slot fillers, which matters because an unfilled slot changes the airflow and the mechanical retention of the modules around it rather than only the appearance of the rack.
SLC 500 processors span 1 K to 64 K of memory and can address up to 4096 inputs and 4096 outputs, and every modular processor except the SLC 5/01 can control remotely located I/O through a scanner. That distinction is what makes a 5/01 unsuitable as the head of a distributed system regardless of its I/O count.
Sizing a SLC 500 system is a fixed sequence, and it is the sequence rather than the arithmetic that stops most retrofits: count the I/O points, convert them into modules at the published channels per module, add a scanner or an adapter where the I/O sits remotely, total the 5V and 24V draws per chassis, choose the power supply that covers both totals, then choose the chassis with enough slots including fillers for the empties. Doing it in the reverse order, from a chassis that already exists, produces a system that fits mechanically and fails electrically.
Backplane budgeting is the arithmetic that decides whether a SLC 500 chassis closes: every module declares its 5V and 24V draw, the power supply declares its internal capacity for both rails, and the sum has to stay below both numbers at once. A chassis that passes on 5V and fails on 24V is the common mistake, because most digital I/O draws nothing from 24V while analog and thermocouple modules do.
Before ordering, confirm the slot count against the I/O list, confirm the 5V and 24V totals against the supply capacity rather than against the wattage, and confirm that the cable and the chassis are ordered separately, because none of these parts is included with any other.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley SLC 500 1746 I/O modules category.