logo
Home ProductsAB SLC-500 Systems 1746

Allen Bradley PLC 1746-A4 / 1746A4

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1746-A4 / 1746A4

China Allen Bradley PLC 1746-A4 / 1746A4 supplier
Allen Bradley PLC 1746-A4 / 1746A4 supplier Allen Bradley PLC 1746-A4 / 1746A4 supplier Allen Bradley PLC 1746-A4 / 1746A4 supplier Allen Bradley PLC 1746-A4 / 1746A4 supplier Allen Bradley PLC 1746-A4 / 1746A4 supplier Allen Bradley PLC 1746-A4 / 1746A4 supplier

Large Image :  Allen Bradley PLC 1746-A4 / 1746A4

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1746-A4 / 1746A4

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $187.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1746-A4 technical data PDF download 1746-A4 SLC 4 Slots Chassis

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: SLC 500 chassis

1746-A4 is the 4-slot chassis of the Allen-Bradley SLC 500 modular system: 1746 SLC System, 4-Slot Chassis-Modular Hardware Style.

The chassis is the part that fixes the machine's I/O count. Every card, the processor and the power supply are sized against the slots and the backplane rails this rack provides.

1746-A2 2-Slot Expansion Chassis IN STOCK
1746-A4 SLC 4 Slots Chassis IN STOCK
1746-A7 SLC 7 Slots Chassis IN STOCK
1746-A10 SLC 10 Slots Chassis IN STOCK
1746-A13 SLC 13 Slots Chassis IN STOCK

Product Specifications 1746-A4 (PDF)
 Application
 1746 SLC System, 4-Slot Chassis-Modular Hardware Style
 Cat Num
 1746-A4
 Brand Name
 Rockwell
 Product Type
 SLC 500 4-slot chassis
 Number of slots
 4
 Chassis
 4-slot chassis, modular hardware style
 Temperature rating
 0...60 °C (32...140 °F)
 Minimum enclosure size, H x W x D
 17.1 x 17.7 x 14.5 cm
 Lifecycle
 Discontinued
 Discontinued date
 March 31, 2024
 Replacement category
 No planned RA replacement

1746-A4 (SLC 500 modular chassis, 4 slots): 4-slot backplane for an SLC 500 modular system. The power supply mounts at the left end and slot 0 is reserved for the processor or an adapter module, so the slots left for I/O depend on how many chassis the system uses.

The chassis mounts straight to the enclosure back panel on its tabs with #10 or #12 screws, torqued to a maximum of 3.4 N·m (30 lb·in). A single SLC 500 system is limited to three chassis and 30 slots of I/O, which is why the 10- and 13-slot frames are normally paired with an interconnect cable rather than expanded again. Source: Rockwell publication 1747-UM011, mounting chapter and the SLC 500 system specifications.

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN016 (module specifications) and 1746-IN016 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1746-A4 original product photograph 1 1746-A4 original product photograph 2 1746-A4 original product photograph 3

What 1746-A4 is

Rockwell description: 1746 SLC System, 4-Slot Chassis-Modular Hardware Style.

It is a 4-slot chassis in the modular hardware style, with a card guide per slot, one backplane connector per slot and a mounting foot at each end.

Technical data

Application: 1746 SLC System, 4-Slot Chassis-Modular Hardware Style.

Cat Num: 1746-A4.

Brand Name: Rockwell.

Product Type: SLC 500 4-slot chassis.

Number of slots: 4.

Chassis: 4-slot chassis, modular hardware style.

Temperature rating: 0...60 °C (32...140 °F).

Minimum enclosure size, H x W x D: 17.1 x 17.7 x 14.5 cm.

Lifecycle: Discontinued.

Discontinued date: March 31, 2024.

Replacement category: No planned RA replacement.

Slot layout and system limits

Slot 0 is reserved for the processor or for a communication adapter; the remaining 3 slots take I/O and specialty modules. The power supply mounts at the left end of the rack and is not a slot.

Rockwell documents the modular SLC 500 system as connecting up to three chassis with 30 I/O modules to a single controller or communication adapter, so a 4-slot rack is one segment of that budget, not the whole limit.

Cards are addressed by slot, so the slot number printed beside each card is what the ladder program uses; moving a card to another slot changes its addresses.

Mounting, enclosure and thermal limits

The rack runs at 0...60 °C ambient and cools by convection, so the enclosure has to let air move past the cards. The minimum enclosure figures Rockwell prints are the space the rack and its terminal blocks need, not a clearance allowance for wiring.

Rockwell lists a minimum enclosure of 17.1 x 17.7 x 14.5 cm (H x W x D) for this chassis.

Field wiring lands on the removable terminal blocks at the front of each card, so the panel needs working room in front of the rack as well as above and below it.

Lifecycle and spares position

Rockwell lists 1746-A4 as discontinued, date March 31, 2024, replacement category No planned RA replacement.

No replacement catalog number is planned, so a failed chassis is replaced from the secondary market or the machine is migrated to a CompactLogix platform.

Rockwell's migration guidance for Bulletin 1746 routes I/O to Compact 5000 modules on a Logix controller; a chassis is the part that cannot be carried across, because the new I/O does not use this backplane.

FAQ — 1746-A4

What is 1746-A4?

1746 SLC System, 4-Slot Chassis-Modular Hardware Style. 4-slot chassis, modular hardware style.

How many slots does 1746-A4 have?

4 slots, of which slot 0 is reserved for the processor or an adapter.

What is the ambient temperature rating of 1746-A4?

0...60 °C (32...140 °F), convection cooled.

Is 1746-A4 still available?

Rockwell lists it as discontinued, date March 31, 2024, replacement category No planned RA replacement.

How many chassis can one SLC 500 controller drive?

Up to three chassis with 30 I/O modules in total, per Rockwell's SLC I/O system description.


Data sources. Technical values on this page come from Rockwell publication 1746-IN016 and the Rockwell product page for this catalog number. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1746 1746-A4: 4-slot chassis

1746-A4 is a 4-slot chassis in the SLC 500 modular range. The chassis is the backplane: it carries the processor or I/O adapter in the left-most slot, the I/O modules to its right, and it is fed by a separate power supply mounted on its left end.

A maximum of three chassis can be linked with chassis interconnect cables, and the cable is chosen by the physical gap between the enclosures rather than by preference: 1746-C7 covers up to 152.4 mm, 1746-C9 covers 152.4 mm up to 914.4 mm, and 1746-C16 covers 0.914 m up to 1.27 m. A gap of 1.3 m is outside the range of every cable in the family.

Heat is part of the same calculation as current: the selection guide carries a heat dissipation figure per module, and the chassis total is the sum of those figures. A rack that is electrically legal and thermally packed still derates in a closed cabinet, which is why the procedure in the guide sums watts slot by slot instead of estimating from the 5V current.

Sizing a SLC 500 system is a fixed sequence, and it is the sequence rather than the arithmetic that stops most retrofits: count the I/O points, convert them into modules at the published channels per module, add a scanner or an adapter where the I/O sits remotely, total the 5V and 24V draws per chassis, choose the power supply that covers both totals, then choose the chassis with enough slots including fillers for the empties. Doing it in the reverse order, from a chassis that already exists, produces a system that fits mechanically and fails electrically.

Remote I/O changes the data path, not the module: with a 1747-ASB adapter in the remote chassis, analog and thermocouple modules require block transfers, and a program written as direct I/O in a local chassis does not simply move to a remote one. The 1746-NO4I and 1746-NO4V analog outputs also accept a user-supplied 24V DC source, and that source must be 24V plus or minus 10 percent; the 1746-P1, P2, P5 and P6 user supplies do not meet that tolerance.

Before ordering, confirm the slot count against the I/O list, confirm the 5V and 24V totals against the supply capacity rather than against the wattage, and confirm that the cable and the chassis are ordered separately, because none of these parts is included with any other.

Browse the Allen-Bradley SLC 500 1746 I/O modules category for the other models, options and spare parts that share this range.