This page documents catalog number 22D-B8P0N104, a PowerFlex 40P drive on the 240 V three-phase class: 1.5 kW (2.0 HP), 8.0 A continuous output at 0-230 V output, frame B, N. The kW, current, input range, fuse, motor protector, contactor and enclosure-volume figures are taken from the published PowerFlex 40P user manual for this rating rather than from a nameplate.
| Field | Value |
| Catalog number | 22D-B8P0N104 |
| Family | 22D - PowerFlex 40P adjustable frequency AC drive |
| Voltage code (character 5) | B - 240 V three-phase input |
| Rating code (characters 6-8) | 8P0 - 1.5 kW (2.0 HP), 8.0 A |
| Frame | B |
| Enclosure (character 9) | N - IP20, NEMA/UL Type Open panel mount |
| HIM position (character 10) | 1 |
| Emission class (character 11) | 0 - internal EMC filter position |
| Version (character 12) | 4 |
| Optional positions 13-14 |
The published row for this code gives 1.5 kW (2.0 HP) at 8.0 A continuous output on a 180-264 V AC input range, with 4.0 kVA and 9.5 A input on the input side where the manual lists them. Input current is lower than output current on a drive at full load, because the DC link carries the power at a different voltage; a panel wired and fused on the output amps is over-protected on the input, and one wired on the input amps is under-protected on the motor cable.
The output voltage ceiling is 0-230 V, which is the phase-to-phase output the drive synthesizes from the 180-264 V AC input. A 480 V class drive driving a 460 V motor is inside that ceiling; a 400 V motor on the same drive runs at a lower voltage limit, so the motor nameplate is checked rather than the drive code.
The manual publishes one branch protection answer per rating rather than a range: a 15 A fuse for this code at 40 degrees C with NEC guidance, with 140M-C2E-C16 or 140MT-C3E-C16 listed as the self-protected combination controller and 100-C12 or 100-E12 as the recommended MCS contactor, in a minimum enclosure volume of 1,655 cubic inches.
On 22D-B8P0N104 the fuse types are constrained as well as the size: IEC installations use BS88 parts 1 and 2 or EN60269-1 type gG, and UL installations require Class CC, T or J fuses. Where the exact rating is not available the manual says to choose the next higher fuse rating, which is the opposite of the instinct that usually governs a panel.
For 22D-B8P0N104 two protection routes are published, and they are not equivalent: both inverse-time circuit breakers and the listed 140M/140MT self-protected combination controllers are acceptable for IEC installations, while UL installations accept inverse-time breakers and the specified 140M/140MT controllers, not an instantaneous-trip motor circuit protector on its own. A 140M selected for a UL panel is a listing question as well as a current question.
Character 9 reads N, which the manual defines as IP20, NEMA/UL Type Open panel mount, intended for a cabinet-mounted drive that relies on the enclosure around it for the working environment. The three forms are the same drive electrically: panel mount, flange mount and plate drive share one rating row, so a change of this character does not change the current, the fuse or the motor protector, it changes the drawing, the heat path and the panel space.
A flange mount moves the heatsink through the wall and leaves the control section inside the cabinet, which is how a drive is kept out of a wash-down area without putting the whole drive in a rated enclosure. A plate drive is supplied without a housing and is not an IP20 product in its own right: the machine builder supplies the enclosure and with it the environmental rating.
The manual lists supply conditions that change the installation rather than the drive: a line impedance below 1 percent reactance, a supply transformer above 120 kVA, power-factor correction capacitors on the line, and frequent interruptions or noise spikes above 6,000 V. The published correctives are a line reactor, an isolation transformer or a bus inductor, and the reactance and transformer-size conditions are called out for the 5.5 kW and 11 kW ratings in particular.
A fifth condition is electrical rather than mechanical: a phase-to-ground voltage above 125 percent of the normal line-to-line voltage requires either removing the MOV jumper to ground or fitting an isolation transformer with a grounded secondary. That is a site measurement, and it is the one item on the list a panel builder cannot see from the drive.
Digital I/O control wire is published as 0.750 mm2 (18 AWG) three-conductor shielded cable such as Belden 8770 where shielding is used, on a 300 V, 60 degrees C minimum insulation rating. Unshielded wire is acceptable where national or local code allows it, and the shielded option is what a drive in a panel with switching contactors usually needs.
The string does not settle the feedback device, the communications adapter or the braking resistor. The HIM position reads 1 and the emission class position reads 0, and this page carries them rather than translating them into part numbers, because the option appendix resolves them per code and a translation from the string alone produces a wrong spare.
A PowerFlex 40P is usually specified as one catalog number and then delivered in one of three mechanical forms, and the mechanical form is the character that changes the drawing rather than the rating.
No lifecycle statement and no price is implied for 22D-B8P0N104. The rating, input range, fuse, motor protector, contactor, enclosure volume and control-wire figures are quoted from the PowerFlex 40P user manual, publication 22D-UM001.
PowerFlex 40P is selected rating by rating rather than by frame: each code in the 240 V three-phase class carries its own current, its own branch fuse and its own listed motor protector, and the step to the next code changes all three at once. The rows below are the published values for the class this catalog number belongs to, with the kW and HP figures the manual prints alongside them.
| Rating code | kW | HP | Output A | Frame | Branch fuse | 140M controller |
|---|---|---|---|---|---|---|
| 22D-B2P3 | 0.4 | 0.5 | 2.3 | B | 6 A | 140M-C2E-B40 or 140MT-C3E-B40 |
| 22D-B5P0 | 0.75 | 1.0 | 5.0 | B | 10 A | 140M-C2E-C10 or 140MT-C3E-C10 |
| 22D-B8P0 | 1.5 | 2.0 | 8.0 | B | 15 A | 140M-C2E-C16 or 140MT-C3E-C16 |
| 22D-B012 | 2.2 | 3.0 | 12.0 | B | 25 A | 140M-C2E-C16 or 140MT-C3E-C16 |
| 22D-B017 | 3.7 | 5.0 | 17.5 | B | 30 A | 140M-F8E-C25 |
| 22D-B024 | 5.5 | 7.5 | 24.0 | C | 40 A | 140M-F8E-C32 |
| 22D-B033 | 7.5 | 10.0 | 33.0 | C | 60 A | 140M-F8E-C45 |
This code, 22D-B8P0, is row 3 of 7 in the class: 1.5 kW (2.0 HP) at 8.0 A continuous output in frame B, protected by a 15 A fuse with 140M-C2E-C16 or 140MT-C3E-C16 as the listed controller. The next row, 22D-B012, is 12.0 A in frame B, so a load that lands between the two belongs on the larger code unless the duty cycle leaves headroom in the smaller one. The row below, 22D-B5P0, is 5.0 A in frame B, so a motor between the two currents has no published row of its own in this class and lands on the larger code.
The frame boundary is the one place where the mechanical answer changes with the rating: 22D-B017 is the last row in frame B at a published minimum enclosure volume of 1,655 cubic inches and 22D-B024 is the first in frame C at 2,069. The cabinet grows at that step even when the motor current barely moves, so the enclosure is sized from the larger row rather than from the motor nameplate.
The fuse column is a ladder of its own and it does not follow the current in even steps: 6 A on 22D-B2P3, 10 A on 22D-B5P0, 15 A on 22D-B8P0, 25 A on 22D-B012, 30 A on 22D-B017, 40 A on 22D-B024, 60 A on 22D-B033. Where the exact rating is unavailable the manual instructs the next higher fuse, and the fuse class is constrained as well - BS88 parts 1 and 2 or EN60269-1 type gG for IEC, Class CC, T or J for UL - so a fuse bought on amperage alone is not a listed installation.
What the 22D-B8P0N104 table does not carry is the input current and the kVA figure for every row: the manual prints them for some ratings and omits them for others, and the omissions are listed as omissions here rather than filled with a neighbouring value. The frame, the fuse and the 140M controller, which is what a panel schedule actually needs, are complete for every row shown.
This page links twelve of the 47 22D records on this site; the closest rating codes come first. This page is 22D-B8P0N104.
For the surrounding range, open the AB Drives & Motors catalogue index — 22D-B8P0N104 is listed there beside the rest of the drive and motor group. It is the entry point used when a project list is assembled group by group.