logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103

China Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier
Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103 supplier

Large Image :  Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103

Product Details:

Place of Origin: Made in CHINA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 22C-D017N103 / 22CD017N103

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $525.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 5 PCS
Detailed Product Description

22C-D017N103

This page documents the 22C-D017N103, a PowerFlex 400 fan and pump drive. The number decodes position by position: 22C is the series, D fixes the 380...480 V AC three phase input, 017 is the rating code that sets 17.0 A and 7.5 kW (10 HP) in frame C, N is the enclosure (panel mount, IP20, NEMA/UL Type Open), and 103, the standard build ending used at both voltages and every frame closes the number.

Catalog number, position by position

PositionValue
1-322C, PowerFlex 400 adjustable frequency drive for fan and pump applications
4D, 380...480 V AC three phase
5-7017, 17.0 A output current and 7.5 kW (10 HP), frame C
8N, panel mount, IP20, NEMA/UL Type Open
9-12103, the standard build ending used at both voltages and every frame

Rating data for this number

AttributeValue
Output current17.0 A
Motor rating7.5 kW (10 HP), variable torque fan and pump duty
FrameC
Power terminal range, frame C8.4 mm2 (8 AWG) maximum, 1.3 mm2 (16 AWG) minimum, recommended torque 3.7 N.m (33 lb.in)
Input voltage380...480 V AC , 340...528 V AC window printed in the rating table
Ambient, panel mount45 C (113 F) surrounding air, IP20 open and IP30 Type 1

Ratings either side of this one

The published table places this rating between 012: 12.0 A, 5.5 kW (8 HP), frame C; 022: 22.0 A, 11.0 kW (15 HP), frame C. When a fan or pump is re-rated, these are the two numbers the drive is compared with, and the frame letter in each case tells you whether the terminal block changes along with the current.

Direct links to the neighbouring ratings in this voltage class: 22C-D012, 22C-D022.

480 v input window in the tables. The 380...480 V AC drives carry a 340...528 V AC input window in the rating tables, wider than the voltage on the nameplate. A loaded transformer sagging to 350 V during a large fan start stays inside that window, and a site running near 500 V stays inside it too; a site above 528 V does not, and that is a transformer tap question rather than a drive question.

The duty this range was written for. The published range covers 3.0...350 HP at 480 V AC and 3.0...50 HP at 240 V AC, all three phase and all variable torque fan and pump duty. That is not a marketing description: the overload profile, the current tables and the built-in pump functions are all written for a quadratic load, and a constant torque load such as a positive displacement pump has to be sized outside those tables.

Interface options and the enclosure rating. Two interface options are published with the drives: a NEMA/UL Type 1 bezel for panel mounting and a NEMA/UL Type 4X/12 remote panel mount unit. The remote part lets an engineer stand at the fan during commissioning, and the bezel is what keeps a Type 1 rating intact after the interface is moved to the door.

Flange mounting is an option with a rating ceiling. Flange mounting is restricted to frames through 15 kW (20 HP) at 380...480 V AC and through 7.5 kW (10 HP) at 200...240 V AC, and the heatsink then passes through the back of the enclosure with an IP66, NEMA/UL Type 4X/12 backside rated for indoor or outdoor use. Above those ratings the option disappears from the selection table entirely, which is why a re-rated fan can lose the flange route without anyone noticing at quotation stage.

The isolation transformer pairing is published. Each rating is paired in the publication with a 1321-3TW or 1321-3TH isolation transformer from 5 kVA to 390 kVA, with 208 V, 230 V, 460 V and 575 V primaries. On a corner grounded delta or an ungrounded system, that pairing is the published route to a drive input voltage the range was tested at, and it is cheaper than arguing about the supply afterwards.

Frame C in practice. Frame C is the frame that changes character with the enclosure code. It ships as IP20 open and reaches IP30 Type 1 only through a field installed conversion kit with a top cover and conduit box, and it is the only frame where flange mounting is available at the lower ratings. The terminal block takes up to 8 AWG at 3.7 N.m, so a 5 HP fan on a long run is a wire size question rather than a lug question.

The three decisions this number does not make. A catalog number fixes the drive, the frame and the enclosure rating. It does not fix the motor cable, the branch protection or the cabinet cooling. The publication sends those to separate documents: 22C-UM001 for terminal wire ranges and wiring practice, the protection tables for the 140M or 100-C device that pairs with the rating, and the ambient statement for the enclosure.

Environmental and installation context

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

Connector shells are the part of the ordering decision a drawing rarely shows. M8 is a single-pin pico shell, M12 is a four or five pin micro shell, M23 is a twelve pin shell, and the same channel count can be delivered in three different shell sizes with three different cable preparations. A plant that standardises on M12 cord sets buys the M12 variant; a plant that already runs M8 patch cables buys the M8 variant and gets the same eight channels in eight single-pin shells, and the field wiring effort differs accordingly.

The mounting base ships with the module, so a spare is ordered as a module and arrives with the metal that does the grounding; a panel that keeps bases in stock and swaps only modules is a panel that still has the old base under the new part.

Figures on this page are the published 22C technical data for this catalog number. Where a value is not printed in that publication it is not printed here either, and no price, lead time or lifecycle statement is implied. The catalog number covered on this page is 22C-D017N103.

Related catalog numbers in the 22C range

Twelve of the 47 22C records carried on this site, ordered by how close their codes sit to this one. This page is 22C-D017N103.

This listing is filed in the AB Drives & Motors group on plc-vip.com; the group index is AB Drives & Motors catalogue index, and the 22C-D017N103 page is one entry in it. It is the entry point used when a project list is assembled group by group.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)