Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103 supplier

Large Image :  Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103

Product Details:

Place of Origin: Made in CHINA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 22C-D012N103 / 22CD012N103

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $478.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 5 PCS
Detailed Product Description

22C-D012N103

This page documents the 22C-D012N103, a PowerFlex 400 fan and pump drive. The number decodes position by position: 22C is the series, D fixes the 380...480 V AC three phase input, 012 is the rating code that sets 12.0 A and 5.5 kW (8 HP) in frame C, N is the enclosure (panel mount, IP20, NEMA/UL Type Open), and 103, the standard build ending used at both voltages and every frame closes the number.

Catalog number, position by position

PositionValue
1-322C, PowerFlex 400 adjustable frequency drive for fan and pump applications
4D, 380...480 V AC three phase
5-7012, 12.0 A output current and 5.5 kW (8 HP), frame C
8N, panel mount, IP20, NEMA/UL Type Open
9-12103, the standard build ending used at both voltages and every frame

Rating data for this number

AttributeValue
Output current12.0 A
Motor rating5.5 kW (8 HP), variable torque fan and pump duty
FrameC
Power terminal range, frame C8.4 mm2 (8 AWG) maximum, 1.3 mm2 (16 AWG) minimum, recommended torque 3.7 N.m (33 lb.in)
Input voltage380...480 V AC , 340...528 V AC window printed in the rating table
Ambient, panel mount45 C (113 F) surrounding air, IP20 open and IP30 Type 1

Ratings either side of this one

The published table places this rating between 010: 10.5 A, 4.0 kW (5 HP), frame C; 017: 17.0 A, 7.5 kW (10 HP), frame C. When a fan or pump is re-rated, these are the two numbers the drive is compared with, and the frame letter in each case tells you whether the terminal block changes along with the current.

Direct links to the neighbouring ratings in this voltage class: 22C-D010, 22C-D017.

The duty this range was written for. The published range covers 3.0...350 HP at 480 V AC and 3.0...50 HP at 240 V AC, all three phase and all variable torque fan and pump duty. That is not a marketing description: the overload profile, the current tables and the built-in pump functions are all written for a quadratic load, and a constant torque load such as a positive displacement pump has to be sized outside those tables.

Interface options and the enclosure rating. Two interface options are published with the drives: a NEMA/UL Type 1 bezel for panel mounting and a NEMA/UL Type 4X/12 remote panel mount unit. The remote part lets an engineer stand at the fan during commissioning, and the bezel is what keeps a Type 1 rating intact after the interface is moved to the door.

Flange mounting is an option with a rating ceiling. Flange mounting is restricted to frames through 15 kW (20 HP) at 380...480 V AC and through 7.5 kW (10 HP) at 200...240 V AC, and the heatsink then passes through the back of the enclosure with an IP66, NEMA/UL Type 4X/12 backside rated for indoor or outdoor use. Above those ratings the option disappears from the selection table entirely, which is why a re-rated fan can lose the flange route without anyone noticing at quotation stage.

The isolation transformer pairing is published. Each rating is paired in the publication with a 1321-3TW or 1321-3TH isolation transformer from 5 kVA to 390 kVA, with 208 V, 230 V, 460 V and 575 V primaries. On a corner grounded delta or an ungrounded system, that pairing is the published route to a drive input voltage the range was tested at, and it is cheaper than arguing about the supply afterwards.

Ambient is a cabinet number, not a drive number. The panel mount drives are published for a 45 C (113 F) surrounding air temperature, and that figure is measured inside the enclosure rather than in the plant. A fan or pump room at 35 C with an unventilated cabinet at 52 C is a drive running 7 C over its published ambient, and the remedy is airflow or the flange option, not a larger drive.

Frame C in practice. Frame C is the frame that changes character with the enclosure code. It ships as IP20 open and reaches IP30 Type 1 only through a field installed conversion kit with a top cover and conduit box, and it is the only frame where flange mounting is available at the lower ratings. The terminal block takes up to 8 AWG at 3.7 N.m, so a 5 HP fan on a long run is a wire size question rather than a lug question.

What a quotation needs beyond the number. A drive number alone will not close a fan package: the panel needs the branch protection device, the installer needs the cable range, and the mechanical designer needs the heat figure. Each of those is published separately from the rating table, which is why a quotation built only from the catalog number tends to come back with three questions attached.

Environmental and installation context

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

The environmental claims in this family are stated per module and per connector: IP65/66/67 applies when the connector caps are tightened, and the installation instructions repeat the attention note that all connectors and caps have to be securely tightened to keep the seal. That single step is where most field failures on sealed I/O originate, and it is a mechanical check rather than a network check.

The default data map matters as much as the rating: a digital module produces one byte and, for outputs, consumes one, and that byte is the channel status and output state the controller actually sees.

Figures on this page are the published 22C technical data for this catalog number. Where a value is not printed in that publication it is not printed here either, and no price, lead time or lifecycle statement is implied.

Related catalog numbers in the 22C range

Of the 47 22C records carried here, these twelve stand closest to this catalog number. This page is 22C-D012N103.

Site tree: the AB Drives & Motors index carries 22C-D012N103 together with the other entries of the drive and motor group, which is where a catalogue walk usually starts. Reach it directly if the suffix on this record still needs confirming against a sibling.

Sources. Rockwell publishes the PowerFlex 400 user manual as 22C-UM001 and the technical data for the family as 22C-TD001. The ratings, terminal designations and ordering characters quoted on this page for 22C-D012N103 follow those two publications.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)