This page documents catalog number 22B-V6P0F104, a PowerFlex 40 drive: 120 V AC single-phase, 6 A, 1.1 kW (1.5 HP), enclosure F, frame B. The decode and every figure below come from the drive family's published selection and installation tables; the option positions the documentation does not resolve are named as unresolved rather than guessed.
| Field | Value |
| Catalog number | 22B-V6P0F104 |
| Family (characters 1-3) | 22B - PowerFlex 40 adjustable frequency AC drive |
| Voltage class (character 5) | V - 120 V AC single-phase |
| Input band as published | 100-120 V AC |
| Output as published | 0-230 V three-phase |
| Rating code (characters 6-8) | 6P0 - 6 A, 1.1 kW (1.5 HP) |
| Frame size | B |
| Enclosure (character 9) | F - IP20 flange mount |
| Emission class (character 11) | 0 - no integral filter (unfiltered drive) |
| Drive type (character 12) | 4 - the family notes that this position indicates drive type and that all PowerFlex 40 drives carry RS485 |
The 120 V single-phase class exists for the plant that has 120 V distribution and needs a three-phase motor to run from it. The published input band is 100 to 120 V AC and the output is three-phase from 0 to 230 V, so the drive is performing the phase conversion as well as the speed control.
Three codes carry this class at 2.3 A, 5.0 A and 6.0 A, covering 0.4 to 1.1 kW, and every one of them sits on frame B. The ceiling is 6.0 A on a single 120 V feed, and a motor that needs more cannot be served from this input however the drive is set up.
The enclosure character of 22B-V6P0F104 reads F, the IP20 flange-mount variant, where the heatsink passes through the back of the cabinet so the heat leaves the enclosure instead of being circulated inside it.
Flange mounting on 22B-V6P0F104 is a mechanical commitment rather than an accessory. The cut-out, the heatsink depth and the seal between drive and panel are fixed by the variant, and a cabinet built for an open drive cannot be converted by cutting a hole afterwards without losing the IP20 rating of the assembly.
On frame B of 22B-V6P0F104 the published power terminal block accepts 5.3 mm2 (10 AWG) maximum and 1.3 mm2 (16 AWG) minimum at 1.7-2.2 N-m (16-19 lb-in), and the I/O terminal block common to frames B and C accepts 1.3 mm2 (16 AWG) maximum and 0.2 mm2 (24 AWG) minimum at 0.5-0.8 N-m. The frame measures 100 x 180 x 136 mm and ships at 2.2 kg.
The emission character reads 0. At 1 the string describes a drive with the integral S-type EMC filter the family lists for this rating; at 0 it describes an unfiltered drive, and the EMC obligation moves to the installation. The manual also gives the cable lengths the two filter families allow: S type for at least 10 m in a Class A environment and 1 m in Class B, L type for at least 100 m in Class A and 5 m in Class B. A filter is not inferable from the power rating, only from this character, which is why 22B-V6P0F104 is read at that position before anything else.
The enclosure does not upgrade the drive; it carries the rating of the enclosure around it, and 22B-V6P0F104 is no exception. The manual states that the drive meets IP40, IP54 and IP65 for NEMA 1, 12, 4 and 4X only when installed inside an enclosure of like rating, which is the sentence that decides whether an open drive is acceptable in a given room.
Dynamic braking on 22B-V6P0F104 is a resistor selection rather than a drive setting: the manual lists 48 ohm, AK-R2-091P500 for this kW rating, and the resistors are rated for 5 percent duty cycle. The resistance changes with the rating rather than staying fixed, so a resistor carried over from a different size does not transfer.
Where the drive needs a line reactor or a DC bus inductor, the manual lists the Bulletin 1321-3R series and the MTE RB series by drive rating, and the larger ratings of the 480 V class are flagged as requiring an external DC bus inductor or AC line reactor rather than being usable bare. For 22B-V6P0F104 the reactor line therefore stays a bill-of-materials question rather than a commissioning note.
The string settles voltage class, output current, enclosure, filter and drive type. It does not settle the motor, the cable, the upstream protection or the duty, and on a drive of this size those four decide whether the installation works. 22B-V6P0F104 is the drive's capability; the installation around it is the engineer's.
Two drives of this family can share a current and a voltage and differ in enclosure or filter, so a spare order that quotes a rounded-off number can produce a unit that runs the motor and does not fit the panel. 22B-V6P0F104 is one of those strings, and quoting it in full is the discipline that prevents that.
In 22B-V6P0F104 the interface position reads 1. The 22B family carries an interface module code in that position, and every PowerFlex 40 drive is stated to include RS485 communication regardless of it, so the RS485 link is a property of the drive rather than of the option. On this page the 1 is not translated into a module type, because the selection table resolves it by rating and the position is not self-describing.
Commissioning a drive of this class starts with the two numbers the string does not carry: the motor nameplate current, which the drive must be limited to, and the acceleration the machine actually needs. On 22B-V6P0F104 the current limit is set from the motor nameplate rather than from the rating row, because a drive this small is usually protecting a motor rather than controlling a process.
No lifecycle statement and no price is implied. The rating rows, the voltage bands, the enclosure definitions, the terminal and frame data, the filter cable limits, the braking resistor selections and the reactor notes behind 22B-V6P0F104 are quoted from the drive family's published selection and installation tables.
Each code in this class is a separate published row rather than a step on a frame ladder: current, frame and braking resistor all move together, and only the enclosure and interface characters are free. The rows below carry the current and the resistor the manual lists for this class, which is what a spare order has to match.
| Rating code | kW | HP | Output A | Frame | Brake resistor |
|---|---|---|---|---|---|
| 22B-V2P3 | 0.4 | 0.5 | 2.3 | B | 48 ohm, AK-R2-091P500 |
| 22B-V5P0 | 0.75 | 1.0 | 5.0 | B | 48 ohm, AK-R2-091P500 |
| 22B-V6P0 | 1.1 | 1.5 | 6.0 | B | 48 ohm, AK-R2-091P500 |
This code is row 3 of 3 in the class: 1.1 kW (1.5 HP) at 6.0 A continuous output on frame B, with a 48 ohm, AK-R2-091P500 braking resistor. The enclosure character on this number reads IP20 flange mount, which is one of the forms the family publishes for this rating: it changes the housing and the drawing, not the current, the frame or the resistor. The code below, 22B-V5P0, stops at 5.0 A, so a motor between the two currents belongs on this rating rather than on the smaller one.
Every code on this ladder sits on frame B at 100 x 180 x 136 mm and 2.2 kg, with a power terminal block taking 5.3 mm2 (10 AWG) maximum at 1.7-2.2 N-m (16-19 lb-in). The cabinet layout therefore survives a motor change anywhere inside this class; only the current, the fuse and the resistor change.
This is a single-phase class whose output is three-phase from 0 to 230 V: the drive converts phase as well as frequency. That is why a 120 V or 240 V single-phase feed can run an ordinary three-phase motor, and it is also why the current on this ladder is an output current - the input current on a single-phase feed is higher for the same kilowatts, and the feeder is sized from the installation tables rather than from this column.
The ladder does not carry the branch fuse or the motor protector for 22B-V6P0F104, and that is not an omission of this page: the family resolves both per rating in its installation tables. A bill of materials assembled from the selection ladder alone leaves two lines for the panel builder, and both are protection decisions rather than accessories.